HonestMann Home Inspections LLC


78 Westview Ln 
Fort Edward NY 12828-4259
Inspector: Tom Mann

Home Inspection Report
Client(s): Erin McGee
Property address: 2 Meadowbrook Rd
Glens Falls, NY 12801
Inspection date: 1/12/2012
This report published on Monday, January 23, 2012 8:33:04 PM EST

View summary page

Thank you again for selecting HONESTMANN HOME INSPECTION, LLC for your pre-purchase home inspection needs. Your satisfaction and peace of mind are very important to me.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
Exterior
Roof
Garage
Attic
Electric service
Fireplaces, woodstoves and chimneys
Basement
Interior rooms
General information
Heating and cooling
Plumbing and laundry
 
Exterior Return to table of contents
Foundation material: Concrete blockSome signs of moister in South corner.
Apparent wall structure: Wood frameFlower box in front of house has rotted the sheathing and possibly studs.
Wall covering: Composition wood clapboardRecommend independent pest inspection. Apears to be termit damage NE side of garage.
1) One or more wires run overhead to trees were found. This is a substandard method of support. It may result in damage to wires and/or connections and is a safety hazard for risk of shock and fire. A qualified electrician should evaluate and repair as necessary..
2) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
    Cost estimate: $ 200.00
    3) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    Cost estimate: $ 100.00

    4) One or more outdoor electric receptacles appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all outdoor receptacles within six feet six inches of ground level have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    Cost estimate: $ 100.00

    5) One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

    Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit:
    http://edis.ifas.ufl.edu/AE113
    Cost estimate: $ 200.00

    6) One or more unlined wooden planter boxes are attached to the side of the house. Wood soil contact exists in such boxes and is a conducive condition for wood-destroying insects and organisms. Recommend either removing them, or modifying them so that no wood-soil contact exists (install plastic or metal liners), and so that they are well drained.
    Cost estimate: $ 500.00

    7) Siding is incomplete or missing in one or more areas. A qualified contractor should install siding where missing to prevent water and vermin intrusion.
    Cost estimate: $ 100.00

    8) Soffit boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.
    Cost estimate: $ 100.00

    9) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.
    Cost estimate: $ 100.00

    10) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    Cost estimate: $ 20.00

    11) One or more gutters are missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install gutters and downspouts where missing. Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.
    Cost estimate: $ 500.00

    12)   Stairs are unsafe due to a non-standard configuration, such as too-high riser heights and/or too-narrow tread depths. Standard building practices call for riser heights not to exceed eight inches and tread depths to be at least nine inches but preferably 11 inches. Riser heights should not vary more than 3/8 inch on a flight of stairs. At a minimum, the client(s) should be aware of this hazard, especially when guests who are not familiar with the stairs are present. Ideally a qualified contractor should repair or replace stairs so they conform to standard building practices.
    13)   One or more electric receptacles are broken or damaged. This is a safety hazard due to the risk of fire and shock. A qualified electrician should replace them as necessary.
     
    Roof Return to table of contents
    Roof inspection method: Not inspectedsnow covered
    Roof type: Gable
    14)   The roof was completely obscured by snow and couldn't be fully evaluated.
     
    Garage Return to table of contents

    15) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    Cost estimate: $ 50.00

    16) One or more garage electric receptacles appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all garage receptacles, except for one for use with a refrigerator or freezer, have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    17) Trip hazard(s) exist at stairs due to non-uniform riser heights. Standard building practices call for riser heights not to vary more than 3/8 inch on a flight of stairs. At a minimum, the client(s) should be aware of this hazard, especially when guests who are not familiar with the stairs are present. Ideally a qualified contractor should evaluate and repair or replace stairs so all riser heights are within 3/8 inch of each other.
    Cost estimate: $ 100.00
     
    Attic Return to table of contents
    Inspection method: Viewed from hatch
    Roof structure type: Rafters
    Insulation material: Vermiculite loose fill
    18) What appears to be vermiculite insulation was found in the attic. This material may contain asbestos, which is a known carcinogen, and may pose a health hazard. However even if this material does contain asbestos, it may not pose a health hazard since it's not in a living space. The client(s) may wish to have this material tested for asbestos by a qualified lab and/or consult with a qualified industrial hygenist or remediation specialist, and should definitely do so if they plan to remove it or disturb it through remodeling. For more information on asbestos use in homes, visit: http://www.cpsc.gov/CPSCPUB/PUBS/453.html
    Cost estimate: $ 100.00
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 100
    Service voltage (volts): 120/240
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Aluminum
    System ground: Cold water supply pipes
    Main disconnect rating (amps): 100
    Branch circuit wiring type: Copper
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: No
    19) Based on the size of the rating of the main service panel, the size of the service conductor wires, and/or the rating of the main disconnect device, it appears that the main service panel is undersized. This is a potential fire hazard. A qualified electrician should evaluate and repair if necessary.
    Cost estimate: $ 700.00

    20) The service drop wires are in contact with trees or vegetation. Recommend having a qualified tree service company or arborist prune or remove trees as necessary to prevent straining or abrading the service drop wires.
    Cost estimate: $ 100.00
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Fireplace type: Masonry
    Chimney type: Masonry
    21) One or more fireplace or woodstove hearths are less than 18 inches deep. This is a fire hazard. At a minimum, non-combustible hearth pad(s) should be installed. Ideally the hearth(s) should be modified as necessary or installed by a qualified contractor so they are at least 18" deep.
    Cost estimate: $ 200.00

    22) One or more chimney flue openings do not have a screen installed. Screens prevent the following:

  • Fire hazard from wood fire sparks and embers exiting flues
  • Wildlife (birds, rodents, raccoons, etc.) entering flues

    A qualified chimney service contractor should install screening where missing. Screens should have holes 1/4 inch or larger.
    Cost estimate: $ 50.00
    23)   One or more chimney flues do not have a rainproof cover installed. They prevent the following:

  • Rainwater entering flues and mixing with combustion deposits, creating caustic chemicals which can corrode flues
  • Rainwater entering flues and causing damage to terracotta flue tiles from freeze-thaw cycles

    A qualified chimney service contractor should install rainproof cover(s) where missing.
     
    Basement Return to table of contents
    Beam material: Solid wood
    Floor structure above: Solid wood joists
    24) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    25) One or more flights of stairs with more than two risers have no handrail installed. This is a safety hazard. A qualified contractor should install graspable handrails that your hand can completely encircle at stairs where missing, and as per standard building practices.
    Cost estimate: $ 50.00

    26) Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains and/or efflorescence on the foundation or floor, water stains at bases of support posts, etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.
    Cost estimate: $ 100.00
     
    Interior rooms Return to table of contents

    27) Two-pronged electric receptacles rather than three-pronged, grounded receptacles are installed in one or more interior rooms. They are considered to be unsafe by today's standards and limit the ability to use appliances that require a ground in these rooms. Examples of appliances that require grounded receptacles include:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. A qualified electrician should evaluate and install grounded receptacles as per the client(s)' needs and standard building practices.
    Cost estimate: $ 200.00
    28) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    29) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html
    Cost estimate: $ 100.00

    30) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    31) Stains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary. Appears to be around chimney.
    32) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
     
    General information Return to table of contents
    Report number: 001-12
    Inspector's name: T. Mann
    Type of building: Single family
    Age of building: 50+-
    Time started: 10:00am
    Time finished: 12:00pm
    Inspection Fee: 300.00
    Payment method: Cash
    Present during inspection: Client(s), Realtor(s)
    Occupied: No
    Weather conditions: Cloudy
    Temperature: Cold
    Ground condition: Frozen
    Front of structure faces: South, East
    Main entrance faces: South, East
    Foundation type: Unfinished basement
    The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Shed, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court, Sea wall, Outbuildings
    33) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
     
    Heating and cooling Return to table of contents
    Estimated age: 20+ years. Recommend inspection by liscensed HVAC Tech.
    Primary heating system energy source: Natural gas
    Primary heat system type: Forced air
    Distribution system: Sheet metal ducts
    34) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to fire and run adquately at time of inspection. Recommend inspection by qualified HVAC Technician.
    35)   Although the funace age is at the end of life the furnace appears to be in good operating conditioin. Recommend a inspection by a qualified Hvac Technician.
     
    Plumbing and laundry Return to table of contents
    Location of main water shut-off valve: Basement
    Water service: Public
    Service pipe material: Galvanized steel
    Supply pipe material: Galvanized steel
    Vent pipe material: Copper
    Drain pipe material: Plastic, Copper
    Waste pipe material: Cast iron
     