Property Inspection Report
Client(s): Bill & Barbara Homeowner
Property address: 2008 Happy House Lane
Roswell, Georgia 30075
Inspection date: 2-12-2008
This report published on 5/20/2008 11:02:20 PM EDT

View summary page





This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Crawl space
Kitchen
Bathrooms
Interior rooms
Fireplaces, woodstoves and chimneys
 
General information Return to table of contents
Report number: Tadlock1664
Structures inspected: Residential
Type of building: Single family
Age of building: Approximately 23 Years
Property owner's name: Brian and Sharron Tadlock
Time started: 12:40 PM
Time finished: 4:15 PM
Inspection Fee: $100
Payment method: Cash
Present during inspection: Property owner(s)
Occupied: Yes
Weather conditions: Clear
Temperature: Cool
Ground condition: Dry
Front of structure faces: Northeast
Main entrance faces: Northeast
Foundation type: Crawlspace


1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
 
Exterior Return to table of contents
Footing material: Masonry
Foundation material: Concrete block
Apparent wall structure: Wood frame
Wall covering: Composition wood clapboard
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Wood panel, Glass panel
2) The soil around the foundation under the water heater discharge pipe is saturated and has standing water. There is also soggy soil in the crawlspace adjacent to this area. Have a qualified contractor reroute the pipe so that any water discharge is directed away from the foundation to prevent water damage.

Photo 6  

3) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 24  

4) The perimeter grading slopes towards the structure in one or more areas. To prevent water penetration into the crawlspace, these areas should be regraded to slope away from foundation.

Photo 3  

5) Fascia board on end of house shows damage from wood destroying organisms. Have a qualified contractor repair and/or replace damaged wood as necessary.

Photo 7  

6) Gutter on right end of house (facing front of house) is dented and appears to be sloped incorrectly. Have a qualified contractor repair/replace as necessary so that the gutter will drain properly.

Photo 25  

7) Anchor strap for gutter leader on front left corner of house is loose/damaged and there is a hole in the leader. Have a qualified contractor repair or replace as necessary.

Photo 9  

8) There is no deck flashing where the deck meets the siding. Recommend that flashing be installed to minimize water penetration and prevent damage to components of the deck structure and the siding.
9) Some minor cracks are visible in the foundation but do not appear to be a major structural concern. Recommend sealing the cracks to prevent water penetration and monitoring the cracks in the future.

Photo 8  

Photo 10  

10) Cracks were found in the driveway. They do not appear to be a structural concern and no trip hazards were found. Recommend sealing the cracks to prevent water penetration.

Photo 23  

11) Minor cracks were found in the sidewalk. They do not appear to be a structural concern and no trip hazards were found. Recommend sealing the sidewalk cracks to prevent water penetration.

Photo 13  

12) Soil is in contact with or less than six inches from siding on right side of the garage. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and the ground.

Photo 14  

13) This property is clad with composition wood fiber siding. Many brands of this type of siding by different manufacturers are known to deteriorate and/or fail prematurely due to moisture penetration. Failure is typically visible in the form of swelling, cracking and delamination, especially at the bottom edges.

Some areas of siding on this structure show the symptoms described above, but it appears that the siding hasn't deteriorated to the point of needing replacement. Have a qualified contractor seal and repaint siding as necessary to prevent problems associated with this siding.

Photo 2  

Photo 5  

Photo 16  

14) Some plumbing penetrations into structure are not caulked to prevent water penetration. Seal as necessary with silicone caulk or a similar product.

Photo 1  

15) Caulking is deteriorating on each side of garage where siding meets concrete. Reseal/recaulk as necessary to prevent water penetration.

Photo 26  

16) Outdoor lighting fixtures have no caulking/watersealing on base of fixture. Recommend sealing the edges around the light base with silicone exterior caulk to prevent water penetration.

Photo 17  

Photo 21  

Photo 22  

17) The paint on the windows, window sills and trim is deteriorating. Clean, caulk and repaint windows and trim work as necessary to prevent water and exposure damage.

Photo 4  

Photo 11  

18) The paint on front door threshhold and trim is deteriorating. Clean, caulk, and repaint the door trim as needed.

Photo 12  
 
Roof Return to table of contents
Roof inspection method: Partially traversed. Viewed from windows and from the ground with binoculars.
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 11 Years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
19) The homeowner provided a receipt to verify that the house was reroofed in 1997. The average useful life expectancy of composition asphalt shingles is about 20 years. The roof appears to be functioning adequately and is in about the middle of its expected life span.
 
Garage Return to table of contents

20) The garage-house door poses a fire risk because it's not fire-rated (metal or solid-core construction). A qualified contractor should replace this door with a fire-rated door.
21) Some areas of the interior perimeter of the garage is excluded from this inspection due to lack of access from stored items.
22)   Garage is deteriorating and/or rotted along bottom edge. Repair damaged areas as necessary and properly clean, caulk and repaint the garage door.

Photo 15  
 
Attic Return to table of contents
Inspection method: Partially traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass loose fill
Insulation depth: 1-4 inches. 12-18 inches is recommended.
23) Handrail for pulldown attic stairs is loose and is a safety issue. Repair as needed and tighten all hardware so that handrail is secured to pulldown assembly.

Photo 20  

24) The attic light is not working. Determine if bulb is bad or if light fixture needs to be repaired. If needed , have a licensed and qualified electrician repair the light.
 
Electric service Return to table of contents
Smoke detectors present: Yes
Primary service type: Overhead
Primary service overload protection type: Undetermined
Service amperage (amps): 150 (approximated) could not open service panel
Service voltage (volts): 120/240
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Undetermined
System ground: Undetermined
Main disconnect rating (amps): 150
Branch circuit wiring type: Undetermined
Solid strand aluminum branch circuit wiring present: Could not verify
25) Electric service panel could not be opened. It appears that the panel has been "glued" in place when the wall cavity was injected with foam insulation. Recommend that a licensed, qualified electrician remove panel and repair as necessary to allow future removal and to evaluate interior of service panel.

Photo 18  
 
Water heater Return to table of contents
Estimated age: 8 to 10 Years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 72
Manufacturer: State
Model: PR 640 NBRS
26) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
 
Heating and cooling Return to table of contents
Estimated age: Less than 1 year
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts, Flexible ducts
Manufacturer: Ameristar
Model: 2TXCB025BC3HCAA
Filter location: At the base of the furnace
Last service date: Recently installed system
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 50
Location of main water shut-off valve: In crawlspace adjacent to furnace
Location of main fuel shut-off: In crawlspace right end of house (if facing the front of house)
Water service: Public
Service pipe material: Not visible
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
27) The main water shutoff valve is missing its handle. Have a qualified contractor repair/replace the handle as necessary.
28) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
 
Crawl space Return to table of contents
Inspection method: Partially traversed
Insulation material underneath floor above: None visible
Pier or support post material: Masonry
Beam material: Built up wood
Floor structure above: Solid wood joists
Vapor barrier present: Yes
29) There is a depression/old drain in the crawlspace near the gas line entry that is very soggy with some standing water. It is in the same area as the wet area described in the Exterior Section, Concern No. 2 of this report. The two issues could be related and the wet area could dry if the wet condition on the exterior of the foundation is addressed. Monitor the crawlspace area after rerouting the drain line as suggested in the Exterior Section, No. 2.

Photo 28  

30)  

Photo 27  
 
Kitchen Return to table of contents

31) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists and repair/replace as necessary.
32) Some of the cabinet and drawer pull handles are loose. Repair and/or replace as necessary.
 
Bathrooms Return to table of contents

33) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists and repair/replace as necessary.
34) The electrical outlet over the sink in the upstairs spare bath is not functioning and does not appear to be a GFCI protected outlet. Have a licensed, qualified electrician evaluate the outlet and replace/repair as necessary.
35) The sink drains in the master and first floor bathrooms are not funtioning properly and will not stay shut. Have a qualified contractor evaluate and repair the drains as necessary for proper operation.
36) The sink faucet in the upstairs spare bath is leaking. Have a qualified contractor repair or replace the faucet as necessary.
37) Some of the cabinet pulls in the first floor bathroom are loose. Tighten all cabinet/drawer hardware as necessary.
38) The toilet base is not properly secured to the floor and is wiggly in the master bathroom. Tighten hardware or repair as necessary in order to properly secure toilet to floor.
 
Interior rooms Return to table of contents

39) The handrail vertical spacing is too wide. This can be a safety issue for very small children. The vertical spacing should be a maximum of 4-inches wide according to current building codes.

Photo 19  

40) Some windows in the front living room area are difficult to open and may be painted shut. Repair as necessary so that windows will open properly.

.

41) Minor cracks were observed in the drywall in some rooms. These were small hairline cracks and do not appear to be a major structural concern.
 
Fireplaces, woodstoves and chimneys Return to table of contents
Fireplace type: Masonry with metal liner
Chimney type: Metal
42) The fireplace hearth is less than 18 inches deep. This is a fire hazard. At a minimum, a non-combustible hearth pad should be installed. Ideally the hearth should be modified as necessary or installed by a qualified contractor so they are at least 18" deep.
43) All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.
 
Ray Perryman, Hawkeye Property Inspections (404) 313-3175