Residential Inspection Report |
| Client(s): |
Mr & Mrs Client |
| Property address: |
1 Hometown Ave Hometown, NY |
| Inspection date: |
Saturday, October 25, 2008 |
This report published on 11/15/2009 10:18:24 AM EST
View summary page
Thank you for choosing HouseAbout Home Inspections. I am confident you will be satisfied with the services I provided. This report outlines the inspection observations, concerns, problems, and any recommendations.
Included in this report is a summary page for your convenience, this is just an overview of major items and/or significant safety related issues that were observed at the time of the inspection. This is not a complete listing of problems, further evaluations needed, or recommendations. In addition, the photographs included may have related commentary with specific references to problems that are only noted in the photo commentary, with just a general reference in the report.
Please read through the entire report and review the photographs with any commentary.
If, after reading the report you have any questions about the report, or conditions of the house, please feel free to contact me.I would be happy to clarify anything that is unclear.
This report is confidential and the exclusive property of HouseAbout Home Inspections and the client(s) listed in the report title. Use or duplication of this report by any unauthorized persons is prohibited. Inspector assumes no liability for any third party misuse or reliance.

David O'Keefe
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Repair/Replace | Recommend repairing or replacing |
 | Improve/Upgrade | Recommend improving/upgrading |
 | Minor Defect | minor expense/or defect |
 | Evaluate | Recommend further evaluation by a specialist |
 | Monitor | Recommend monitoring in the future |
 | Informational Comment | For your information |
Structural Pest Inspection Concerns
Concerns relating to the structural pest inspection are shown as follows:
 | Infestation | Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) |
 | Damage | Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) |
 | Conducive conditions | Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Overview: A quiet residential neighborhood
Weather conditions: Rain
Temperature: Cool
Ground condition: Wet
Present during inspection: Owner
Occupied: Yes
Report number: 20080003
NYS License #: 16000038229
Time started: 10:00 AM
Time finished: 1:00 PM
Age of building: Approximately 30 Years
Type of building: Single family
Main entrance faces: West
Foundation type: Basement
The following items are excluded from this inspection: Shed, Playground equipment
1)
Numerous wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items, preventing a full evaluation of some areas.
2)
Concerning mold in a home / building. While we will report any substance that appears to be mold, the only true way to determine if mold is present is to have a mold company/specialist inspect and test for mold. HouseAbout Home Inspections does not perform mold testing or mold inspection's. Any mention of mold in this report should be considered a recommendation to bring in a mold specialist to inspect and test for mold. If you have a specific concern regarding mold, consult a mold specialist for advice.
For more on mold issues visit;
http://www.inspect-ny.com/sickhouse.htm
http://www.epa.gov/mold/pdfs/moldguide.pdf
3)
1) Today's inspection is being done using the Standards of Practice of the
National Association of Certified Home Inspectors (NACHI) as a
Guideline. The inspection contracts and the limitations and standards
specified therein are an integral part of this report. For a listing of the Standards of Practice go to [url="http://www.nachi.org/sop.htm?PHPSESSID=21528897964cd8c765741b9154e8bd7d']Standards of Practice[/url].
2) Environmental issues are out of the scope of today's inspection and should be addressed separately. This inspection will not result in the information of presence of any environmental hazard that may be present, although if noticed
in the course of my inspection may be reported as a possible concern. There may be environmental concerns that although may be present were not seen by the inspection today since I am not here for that type of inspection.
3) Water is a very destructive force and should be controlled on the outside
to reduce problems that may go undetected for some time on the inside/under the house. Drainage patterns should be monitored and improved as needed to carry water away from foundation. Extend leaders to discharge at least 6' away from building to reduce moisture penetration and foundation damage.
4) Moisture problems may exist in the basement/crawl space as noted in the report and should be evaluated/corrected as possible serious issues. Moisture is a very destructive force that over time may result in structural issues along with health related issues. Environmental issues are out of the scope of today's inspection however and should be evaluated separately if warranted.
4)
Structures built prior to 1980 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
http://www.epa.gov
http://www.cpsc.gov
http://www.cdc.gov
Roof inspection method: From Ground
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Number of layers: One
Estimated age of Roof: Beginning of its useful life
Roof Penetrations: Chimney, Vent Pipes, Antenna
Defects Observed: None
Roof requires this action: Requires nothing
Chimney made of: Metal
Spark arrester/rain cap: Noted
Visible Roof Ventilation: Gable Vents, Ridge Vents, Soffet Vents
Flashing: Good
Gutter & downspout material: Aluminum
Gutter & Downspout Condition: Good
5)

Photo 18
|

Photo 19
|

Photo 20
|

Photo 24
|

Photo 7
|

Photo 16
|

Photo 17
|
|
Apparent wall structure: Wood frame
Wall Covering Material: Vinyl
General Condition of Covering: Good
Trim: Vinyl, Aluminum
Trim Condition: Good
Exterior Doors: Metal, Wood
Doors: Operated well
Windows: Screens, Vinyl , and Wood
Main Entry Porch: Concrete
Roof: No
Steps down: Three or more
Primary service type: Underground
Service size: 200 Amp Aluminum
Meter amperage (amps): 200
Service voltage (volts): 120-240
6)
Wood trim on window in rear of house has deteriorated. Rot or water infiltration is likely to accrue in this area. Recommend repairing or replacing trim and painting it to protect it in the future.

Photo 13
Deteriorated window trim
|
|
7)
Exterior outlet has a broken plug in the socket. Recommend repairing or replacing outlet.

Photo 89
|
|
Exterior of foundation walls: Block
Exterior Foundation Exposure: Approximately 2 foot
Exterior foundation, observed: Small cracks
Driveway material: Asphalt
Driveway condition: Depression or holes
Walkway to front entry: Asphalt
Condition of walkway: Good and poses no tripping hazard
Patio: Pavers
Location of Patio: Rear of house
Patio condition: Fair,Acceptable but has minor crackes
Grading within 6 feet of house: Slopes toward house in rear and right side
Grading beyond 6 feet of house: Slopes away from house
Trees & Shrubs too close to house: In the front of the house
8)

One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.
Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079

Photo 14
|
|
9)
Cracks, settlement and/or heaving areas were found in the driveway. Recommend having a qualified contractor evaluate and repair or replace driveway sections as necessary. Recommend resealing driveway.

Photo 1
Cracked driveway
|

Photo 2
Cracked driveway
|
10)
Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

Photo 6
|

Photo 8
Shrubs close to house
|
11)
Perimeter grading slopes towards building. Recommend grading soil so it slopes down and away from the building to direct rainwater away.

Photo 21
Rear of house
|

Photo 22
Right side of house
|
12)
Small cracks and missing mortar were noted on foundation wall. Recommend repairing these areas to prevent further deterioration of foundation wall

Photo 29
Missing mortar
|

Photo 30
Missing mortar
|
13)
Some of the patio pavers are cracked or have sunk down. Only minor damage has accrued thus far.Recommend repairing these pavers before any more damage can accrue to prevent a trip hazard from forming.

Photo 12
Damaged and sunken pavers
|
|
14)

Photo 3
Gas & Electric meters
|

Photo 5
Intake & exhaust for furnace
|

Photo 9
Right side
|

Photo 10
Back
|

Photo 11
Rear Entrance
|

Photo 25
Basement window
|

Photo 98
Driveway
|

Photo 100
Front Entrance
|

Photo 101
Front of house
|
|
Cabinets: Wooden
Opened and closed and found: Seemed to function
Cabinets secure: Yes
Counter Tops: Plastic Laminate
Securely fastened: Yes
Kitchen Floor: Sheet Linoleum
Dishwasher: GE
Operated Dishwasher: No, In use during inspection
Dishwasher age: Midlife
Kitchen Sink: Stainless Steel
Ran water and found: No leaks
Disposal: None noted
Refrigerator: Kenmore
Refrigerator in use during inspection: Yes
Age: Midlife
Range:: Kenmore
Range type: Free standing
Age: Midlife
Operated and found: All burners working
Oven: Part of stove
Operated oven and found: Gave off heat
Anti-Tipping bracket installed: No
Ventilation: Fan recirculates air within the room
Number of GFCI outlets in Kitchen: 3 or more
GFCI outlets were working properly: Yes
Number of Regular outlets in kitchen: Three
Washing Machine: Maytag
Age: Midlife
Location: Basement
Observed: Connections for water and drain, Connections for electric
Operated: In use during inspection
Dryer: Frigidari
Dryer age: Midlife
Vented to: Exterior
Power: Electric
Operated: In use during inspection
15)

The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

Photo 47
|
|
16)

The clothes dryer exhaust duct appears to need cleaning. Significant amounts of lint build up was found. This is a safety hazard due to the risk of fire from decreased air flow. This duct should be cleaned now and annually, or more often if necessary in the future. Some chimney sweeps or heating/cooling duct cleaners perform this service. For more information, visit http://www.cpsc.gov/CPSCPUB/PUBS/5022.html or http://chimneykeepers.com/dryerclean.html

Photo 23
|
|
17)
Kitchen stove does not appear to have an anti-tipping bracket installed. This could prove hazardous for children. I recommend an authorized stove repair company install this safety device.

Photo 91
SAMPLE PHOTO
|
|
18)
The clothes dryer exhaust duct runs across an electrical outlet and an electrical panel box. This is a safety hazard due to the possibility of fire. Recommend moving exhaust duct away from any electrical outlets or panels.

Photo 48
Vent hose in front of electric panel
|

Photo 55
Dryer vent near outlet
|
19)
Kitchen and Laundry pictures
Main Bathroom: Full
Shower: With tub
Tub: Built in
Surround: Plastic
Surround Condition: Good
Number of sinks?: One
Sink Type: Vanity
Sink Condition: Good
Toilet: Flushed
Toilet Condition: Loose
Leaks: None noted
Floor: Ceramic Tile
Floor Condition: Good
Caulking appears: Intact
Ventilation: Window, Fan
Outlets: One
Ground Fault Interupter Outlets?: Yes
GFCI outlets were working properly: Yes
20)

Toilet is loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.
21)
Sink and tub drain slowly. Recommend clearing drains.
Tips for clogged drains:
Keeping the Drains Clear:
1. By pouring a pot of hot water down the drain once a week will melt away any fat or grease that may have built up in the drain line or P-trap.
2. If you have a clogged drain, just pour a 1/2 cup of baking soda and 1/2 cup of white vinegar down the drain. Cover the drain and let the mixture sit for a few minutes, then pour a pot of hot water down the drain. This will break down fats and also keep the drains smelling fresh.
3. Every six months, keep your drains clean by using a copper sulfide or sodium hydroxide-based drain cleaner, or other recommended drain cleaner available from your local store.

Photo 27
|
|
22)

Photo 26
Main bathroom
|
|
Bathroom: Full
Shower: Stall
Surround: Plastic
Surround condition: Fair,Acceptable
Sinks #: One
Sink Type: Vanity
Sink Condition: Fair,Acceptable
Toilet: Flushed
Toilet Condition: Fair,Acceptable
Leaks: None noted
Floor: Vinyl
Floor Condition: Fair,Acceptable
Ventilation: None noted
Number of outlets: One
Ground Fault Interupter outlets: No
23)

No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.
24)

Photo 39
Bathroom/laundry room
|

Photo 41
Bathroom/laundry room
|
Ceilings appear to be made of: Drywall
Ceiling Style: Flat
Ceiling Condition: Good
Major Defects: None Noted
Mostly walls appear to be made of:: Drywall
Wall Condition: Good
Outlets: Generally all outlets are 3 prong
Floor coverings are mostly: Hardwood, Sheet Linoleum, Wall to wall in family and rec rooms
When bounced on: A normal amount of bounce was noted
Generally floors feel: Level
Mostly the doors are the following types: Hollow core, Wood
General door condition: Doors are generally in good condition
Windows were mostly observed to be: Double hung
Appear made of: Wood, Vinyl
Random Tested: Yes
Stairs: To basement, Between living levels
Stairs condition: Good
25)

Photo 31
Living room
|

Photo 32
bedroom #2
|

Photo 33
Living room
|

Photo 34
living room
|

Photo 35
Bedroom #2
|

Photo 36
Bedroom #3
|

Photo 40
Bedroom #1
|

Photo 42
Family room
|

Photo 43
Family room
|

Photo 44
Bedroom #1
|

Photo 45
Rear slider door
|
|
Heating System Brand Name: Rheem
Apparent age of unit: Newer
Heating system type: Forced hot air
System has # of Zones: One
Fuel Source: Gas
Combustion Air Supply: Exterior
Flue pipes: Noted
Automatic shut-off safety devices were noted: Above the unit
Distribution system: Ductwork
Heat distribution: In most rooms
When thermostats were turned on, the system: Fired or gave heat
Central Cooling: Central Air
Manufacturer: Rheem
Approximate age of system: Newer
A/C energy source: Electric
Air conditioning type: Split system
Distribution system: Sheet metal ducts
Filter location: At the base of the furnace
Status: Not operated due to air temperature below 65 degrees. Operation could cause damage. No readily visible problem noted.
26)
Recommend that this system be serviced every two years in the future by a qualified heating and cooling technician.
Visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

Photo 53
Furnace shutoff
|

Photo 54
Furnace
|

Photo 57
Furnace
|
|
27)
The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Damage can accrue to unit if operated under these conditions. Because of this, the inspector was unable to operate and fully evaluate the cooling system.

Photo 4
AC compressor
|
|
Water heater is located in: Basement
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
Brand: Rheem
Model: 21-VP50-1
Estimated age: Beyond the end of its useful life.
Supply shut off valve: Noted
Safety relief valve: Was noted
Safety extension: Was noted
Drain discharge to:: Floor
Rust or Corrosion: Was not noted
Tested hot water: Hot water was received at faucets Temperature was 114 degrees F
28)
The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 56
Water heater
|

Photo 58
Water heater systems
|
Water service: Public
Main entry pipe material: Copper
Location of main water meter: Basement In laundry/bathroom
Location of main water shutoff: Next to meter
Interior supply pipes: Copper
Functional Flow: Tested
With multiple fixtures running observed: Acceptable decrease in flow
Waste System Pipes: Plastic, Cast Iron
Main waste line cleanouts: Noted
House Trap: Not noted
Vent pipe observed on roof: Yes
Vent pipe connection to plumbing observed: Yes
Vent pipe material: Plastic
29)
Plumbing drain uses an s-trap rather than a vented p-trap. Water seals (the water lying in the bottom of the u-shaped pipe) may be lost when discharges occur in the system, resulting in sewer gases entering the structure. Recommend having a qualified plumber evaluate and replace s-traps with vented p-traps where necessary.

Photo 60
|
|
30)
Location of Main Panel: Basement
Service conductor material: Aluminum
Service voltage (volts): 120/240
Location of main disconnect: Top bank of breakers in main panel (split bus)
Main disconnect rating (amps): Not applicable, no single main disconnect
Primary service overload protection type: Circuit breakers
Branch circuit wiring type: Non-metallic sheathed ("Romex")
Solid strand aluminum branch circuit wiring present: No
Double tapped breakers: Yes
Room for additional circuit breakers: Yes
Missing Circuit Breaker Covers: No
15 Amp Breaker: 14 Gurage wire
20 Amp Breakers: 12 Guage Wire
30 Amp Breakers: 10 Guage Wire
50 Amp Breakers: 6 Guage Wire
Grounding observed to:: Unable to determine if grounded
Location of Sub Panel: Basement-laundry room
Smoke detectors present: No
31)

White conductors are only allowed to be used for grounded conductors (not 'hot' conductors), and, when use for other than grounded conductors (i.e., when used as 'hot' conductors) the white conductors are required to be re-identified by painting, taping or other approved means , and must be permanently re-identified with a color suitable for that use, i.e, "black" or "red" in most cases. This permanent re-identification is to be done at all terminations and at all areas visible and accessible, i.e., if you can see the white wire used as a 'hot' wire and you can access it, then that portion must be permanently re-identified to the appropriate color.
This is a safety concern.

Photo 63
|

Photo 92
|
32)

I was unable to locate the ground wire from the service panel. The service must be connected to a ground rod outside the house and also bonded around the water meter in the house. A jumper connected on both sides of the meter must be made to allow the meter to be removed without losing a ground connection. Recommend a qualified and licensed electrical contractor evaluate and make repairs as necessary.

Photo 62
|

Photo 94
|
33)

One or more screws are missing or are the wrong type from the main service panel cover and should be replaced. Because energized wiring may exist behind the holes with the missing screws, recommend that a qualified, licensed electrician replace these screws, or that care be taken to ensure that the new screws do not come in contact with wiring inside the panel when they are installed. Stock screws from the panel manufacturer should be used, or their equivalent.
34)

One or more overcurrent protection devices(circuit breakers or fuses)in the panel were "double tapped", where two or more wires are clamped in a terminal designed for only one wire. Some circuit breakers are designed to accept two wires, this could not be determined. This is a safety hazard since the bolt or screw may tighten securely against one wire, but leave others loose. Arcing, sparking and fires may result. Recommend having a licensed electrician evaluate and repair.

Photo 65
|
|
35)

The legend for overcurrent protection devices (breakers or fuses) in the main service panel is missing, unreadable or incomplete. Recommend installing, updating or correcting the legend as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.

Photo 59
Incomplete legend
|
|
36)

The sub panel cover couldn't be removed due to lack of access from the dryer duct.This panel wasn't fully evaluated. Repairs should be made so the panel cover can be easily removed.

Photo 88
|

Photo 95
|
Basement: Readily accessible
Basement: Full
Viewed by: Walked throughout
Foundation walls: Some walls were hidden
Interior of foundation wall material: Block
Observed on interior wall: Small cracks, Effloresence
Ceiling framing: Exposed to view
Floor structure above: Solid wood joists
Beam material: Built up wood
Pier or support post material: Steel
Support columns condition: Appear intact
Windows: Wood
Chimney in basement: Metal
Chimney condition: No longer in use
Sump pump: None noted
Ventilation: Windows
Insulation material underneath floor above: None visible
General area dampness: Efflorscence
Basement floor: Concrete
Floor drainage: None noted
37)

Wire splices and/or wiring are exposed due to not being contained in a covered junction box. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes with cover plates where needed to contain wiring splices.

Photo 50
Exposed connections
|

Photo 51
|
38)
White efflorescence (powder substance) on block wall indicates moisture is in contact with the masonry. This does not necessarily indicate that intrusion will occur. I recommend checking the gutters and the downspout drain lines for proper operation. Also, a water proofing paint could be applied to the interior side of the block if necessary. Efflorescence is found on many homes without water intrusion occurring inside the home. But, it should alert you to the possibility that future steps may be needed.

Photo 64
|

Photo 66
|
39)
Small cracks were observed on the basement walls which is not uncommon for a house this age. Recommend monitoring cracks in the future for continued movement.

Photo 68
|

Photo 71
|
40)

Photo 67
Basement rec room
|

Photo 70
|

Photo 72
Basement rec room
|

Photo 73
Basement
|

Photo 74
Basement
|

Photo 75
Basement
|
Attic access: Attic door
How observed: Walked thru end to end
Roof system: Rafters
Inches apart: 18 inches
Roof decking: Plywood
Moisture penetration: Rust on nails Water stains around vent pipe
Attic floor framing: Wood
Attic floor system: Some flooring
Attic Ventilation: Ridge Vent, Soffit Vents, Fan, Gable Vents
Soffit vents: Yes, and working
Bathroom vent: Appears to terminate in atttic
Insulation material: Fiberglass roll or batt
Insulation location: Floor
Insulation depth: six inches
41)

Exposed wiring due to splices not being contained in junction box. Recommend having a licensed electrician install junction boxes with cover plates where needed to contain wiring splices.

Photo 77
Exposed wire connections
|

Photo 84
|
42)

No fireblock is installed around the metal chimney. Fireblocking provides a cut off in concealed draft openings (both vertical and horizontal) and forms an effective fire barrier between stories, and between a top story and the roof space. The fireblocking of spaces between chimneys and Wood joists, beams or headers shall be self-supporting or be placed on strips of metal or metal lath laid across the spaces between combustible material and the chimney. Recommend installing fireblocking where necessary or, because the chimney is no longer in use, removing the chimney and sealing up the chase properly. A qualified contractor should make the necessary repairs.

Photo 79
Chase for chemney
|

Photo 93
Fireblock for chimney- SAMPLE PHOTO
|
43)
One or more exhaust fans have no duct and terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should install ducts and vent caps as necessary and as per standard building practices so exhaust air is vented outside.

Photo 85
|
|
44)
Insulation in attic is less than an R30 rating. Recommend installing additional insulation for better energy efficiency.
45)
No insulation or weatherstripping is installed over the attic access door. Recommend installing insulation behind door for better energy efficiency.
Visit: http://www.batticdoor.com/ for product information.

Photo 38
Attic access
|
|
46)
A mold like substance was observed on the roof sheeting. While we will report any substance that appears to be mold, the only true way to determine if mold is present is to have a mold company/specialist inspect and test for mold. Mold in attics is due to poor ventilation and moisture. Ventilation in this attic has been improved recently with the addition of a ridge vent and soffit baffles. New roof shingles were recently installed also. Recommend monitoring attic for any increase in mold and venting bathroom exhaust to exterior.

Photo 81
|

Photo 86
|
47)
Stains were visible on the roof structure in one or more areas. These areas were dry at the time of the inspection. The stains may be caused by a past leak.

Photo 82
|
|
48)
Attic pictures
Ground Fault Interrupter (GFI): Noted
Location of GFCIs: Kitchen, Bathrooms, Outside
GFI tested: Using testing plug, Using test button
AFCI breakers present: No
Location of Smoke detectors: Each Floor
Carbon Monoxide Detectors: No, unable to locate
49)

All houses, buildings and each unit in a multi-family house should have a carbon monoxide (C/O) detector . A (CO) detector was not located in this house. The detector should be mounted low toward the floor as carbon monoxide is heavier than air. Several C/O detectors are best. One near the heating system and hot water supply and one on each floor of the home. Again, mount C/O detectors low toward the floor.
http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
http://www.homesafetycouncil.org/index.aspx
50)

Smoke Detectors are noted when present but are not tested or inspected. It is recommended that all smoke detectors be replaced when new owners move in. Ionization technology responds first to fast, flaming fires while photoelectric technology responds faster to slow smoldering fires. Having both types would be ideal. When installing detectors it is recommended that they be placed at each level and in each bedroom of the house. Placement should be in accordance with manufacturer's recommendations. Smoke detectors should be replaced at 10 year intervals or per manufacturer's suggestion. Batteries should be changed twice a year.
For more information on smoke detectors visit http://www.cpsc.gov/cpscpub/pubs/5077.html

Photo 37
|
|
51)

AFCI(Arc Fault Circuit Interrupter) breakers provide increased protection by detecting a condition known as an arc fault, which can occur from damaged wiring, overheated or stressed electrical codes, worn electrical insulation, wires and/or cords in contact with vibrating metal, damaged electrical appliances and more.
AFCIs are intended to mitigate the effects of arc faults by de-energizing the circuit when an arc fault is detected.
Two types of AFCIs are available — branch/feeder and combination. Both types are intended to be installed at the origin of a branch circuit or feeder, such as a panel board or load center. The branch/feeder AFCI detects parallel arcing faults, which can occur line-to-line, line-to-neutral and line-to-ground.
The combination AFCI takes the technology one step further and detects not only parallel arcing, but also series arcing, which is useful in identifying lower-level arcing in both branch circuits and power supply cords. A series arc can occur when the conductor in series with the load is unintentionally broken.
Infestation evidence noted: None
Damaged wood: None noted
Conditions are conducive to WDI: Yes
Crackes in Foundation: Yes
Stucco/Brick Veneer Carried over Foundation: No
Concrete Porch Earth Filled: No
Form Boards: No
Wood Steps in Contact with Soil: No
Wood set in Concrete: No
Siding Near/Contacting Soil: No
Construction Debris in Backfill: No
Soil Filled Planters Against Structure: No
Fences/Trellises Against Structure: No
Forms Left in Slab Around Pipes: No
Paper Collers Around Pipes/Ducts: No
52)
Due to the cryptic nature of termites it may not be possible to determine conclusively whether or not termites are present simply based on visible evidence of termite infestation. Destructive testing or damage to the premises may be necessary to detect infestations.
53)
Cracks in concrete foundations and open voids in concrete foundations are conducive conditions for wood destroying insects and should be repaired.

Photo 96
|
|
54)
Bathroom vent terminating in attic is a conducive condition for wood destroying insects and should be repaired.
Device Serial Number(s): #20009555, #20009545
device Type(s): Short term
Number of Devices Used: Two
Foundation Type: Basement
Foundation Material: Block
Below Floor Ventilation: No
Test Area: Occasionally Occupied
Test Location: Basement
Test Area Closed Prior to Test: Yes
Weather Conditions at Time of Test: Rain, Damp
Radon Level: 3.5 average
55)
The property was tested using short term protocols for the presence of radon using the above listed device. The test and analysis have been performed to comply with EPA radon test protocols. The average radon concentration at the time the sampling was conducted and the specific location within the building is listed above. Be aware that radon concentrations will vary from day to day and from season to season. No tampering was observed during the radon test.
For more information visit;
http://www.epa.gov/radon/pubs/citguide.html
http://www.nyradon.org/

Photo 97
|
|
56)
The average level of the two canisters is 3.5 pCi/l. This is below the required action level set by the EPA, so no action is required at this time. However, it must be noted that radon concentrations will vary from day to day and from season to season. The EPA suggests getting a property tested for radon every two years, or if any major changes above/or additions have been done to the property. Radon levels less than 4.0 pCi/L still pose some risk and in many cases may be reduced. If the radon level in your home is between 2.0 and 4.0 pCi/L, EPA recommends that you consider fixing your home.
The national average indoor radon level is about 1.3 pCi/L. The higher a home’s radon level, the greater the health risk to you and your family. Smokers and former smokers are at especially high risk. There are straightforward ways to fix a home’s radon problem that are not too costly. Even homes with very high levels can be reduced to below 4.0 pCi/L. EPA recommends that you use an EPA or State-approved contractor trained to fix radon problems.
For more information visit:
http://www.epa.gov/radon/pubs/citguide.html
http://www.nyradon.org/
Virtually all real estate has problems, regardless of age or usage. It is not my purpose to compile a complete, definitive, or exhaustive list of items that need repair, but to document the general condition of the residence and to note any visible major defects. This is not a comprehensive document about the structure and should not be relied upon as such. Cosmetic considerations (paint, wall covering, carpeting, window coverings, etc.) and minor flaws are not within the scope of the inspection. Although some minor and cosmetic flaws might be noted in this report as a courtesy to you, a list of the minor and cosmetic flaws noted here should not be considered a complete, definitive, or exhaustive list and should not be relied upon as such. Routine maintenance and safety items are not within the scope of this inspection unless they otherwise constitute visible major defects as defined in the Home Inspection Agreement. This report does not include all maintenance items and should not be relied upon for such items.
All conditions are reported as they existed at the time of the inspection. The information contained in this report may be unreliable beyond the date of the inspection due to changing conditions.
Home Inspectors, Licensed Specialists, and Experts;
Inspectors are generalists, are not acting as experts in any craft or trade, and are conducting what is essentially a visual inspection. Some state and local laws, therefore, require that inspectors defer to qualified and licensed experts (e.g., plumber, electrician, et al.) in certain instances. If inspectors recommend consulting specialists or experts, it is possible that they will discover additional problems that a home inspector generalist cannot. Any listed items in this report concerning areas reserved by New York law to such licensed experts should not be construed as a detailed, comprehensive, and/or exhaustive list of problems or areas of concern.

David O'Keefe