1) One or more downspouts are loose or detached. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend making repairs as necessary so downspouts are securely anchored and functional.
See photo(s):
12 |
 |
2) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend making repairs as necessary such as repairing or installing splash blocks or tie-ins to underground drain lines so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
See photo(s):
13 |
 |
3) One or more gutters are damaged. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend having a qualified contractor replace or repair gutters where necessary.
|
  |
4) Minor cracks were found in the sidewalk. These are only a cosmetic concern and no action is recommended.
|
| |
5) The flashing around the chimney should be corrected, so water does not penetrate.
See photo(s):
12 |
   |
16) Recessed "can" lights are installed in the ceiling below the attic. The inspector was unable to find a label or markings that indicated if these lights are designed to be in contact with insulation, and one or more lights are in contact with insulation. This is a possible fire hazard. Recommend trying to determine if these lights are rated for contact with insulation. If they aren't, or if their rating can't be determined, recommend repairing or installing barriers to keep insulation away from these lights and moving or removing insulation as necessary.
|
 |
17) The ceiling insulation's R rating significantly less than what's recommended for this area. Recommend having a qualified contractor install additional insulation as per standard building practices for better energy efficiency.
See photo(s):
4 |
 |
18) The vents at each end ot the attic are covered with plastic and that should be removed to allow air to flow thru the attic area and prevent any possible moisture.
See photo(s):
3 |
 |
19) No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
|
 |
20) There is old knob and tube wiring in the attic, but do not believe it is used as the electrical was redone in the 80's.
|
  |
24) No ground fault circuit interrupter (GFCI) devices (receptacles or circuit breakers) are visible in one or more bathrooms. GFCI devices help prevent electric shocks in areas that may have water present. Recommend having a qualified, licensed electrician install GFCI protection for receptacles over counter tops and around sinks as per standard building practices.
|
  |
25) This home was built before 1978, when laws were enacted in the US preventing the use of lead paint in residential structures. Lead paint may be present, and is a known safety hazard, especially to children but also to adults. It may cause brain damage and retarded mental and physical development, among other things. The paint found in and around this structure appeared to be intact and and most likely encapsulated by more recent layers of paint that's not lead-based. However, recommend following precautions as described in the following links to Consumer Products Safety Commission website articles regarding possible lead paint.
What You Should Know About Lead Based Paint in Your Home: Safety Alert - CPSC Document #5054
CPSC Warns About Hazards of "Do lt Yourself" Removal of Lead Based Paint: Safety Alert - CPSC Document #5055
|
  |
26) One or more light fixtures are inoperable. Recommend having a qualified electrician evaluate and repair or replace fixture(s) as necessary. Within the entry area on the south side the west track lighting fixture is broken and the light does not work. The outside light on the west side by that entry is broken and should be replaced.
|
 |
27) The door for the washer and dryer on the main floor is not on its track and should be repaired.
|
 |
28) The smoke detector in the hallway on the main floor and the light next to it is not in its socket and should be repaired.
See photo(s):
2 |
 |
29) The bedroom on the main floor on the west side has a closet. The light within it is not in its socket and should be repaired.
See photo(s):
1 |
 |
30) The patio door on the main floor does not lock and should be repaired.
|
 |
31) The main floor bathroom has a drawer on the bottom left side that is not on its track and does not open properly.
|