Doyle Home Inspection
Client(s): Wenz
Property address: 13731 Magnolia Dr. Plainfield, IL
Inspection date: 6/11/2010
This report published on Friday, June 11, 2010 7:08:53 PM CDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms

 
General information Return to table of contents
Structures inspected: Townhome
Age of building: 20
Inspection Fee: $240
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Partly cloudy
Temperature: Hot
Foundation type: Slab on grade
The following items are excluded from this inspection: Water softener system
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
 
Exterior Return to table of contents
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Brick veneer, Metal
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel, Sliding glass
2) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.
3) One or more electric receptacles appear to have no power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Photo 9  
no power to GFCI outlet
 

4) One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.

    Photo 2  
    small foundation crack

    Photo 3  
    small foundation crack

    5) The exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.
     
    Roof Return to table of contents
    Roof inspection method: Viewed from eaves on ladder
    Roof type: Cross gable
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 2
    Gutter & downspout material: Aluminum
    Roof ventilation: Adequate
     
    Garage Return to table of contents

    6) Cracked cement floor

    Photo 21  
    corner of garage cement slab is cracked
     

     
    Attic Return to table of contents
    Inspection method: Viewed from hatch
    Roof structure type: Trusses
    Ceiling structure: Trusses
    Insulation material: Fiberglass loose fill, Fiberglass roll or batt
    Insulation estimated R value: 33
    7) Ceiling insulation is uneven in some areas. This is likely due to someone having walked on or through the insulation. Recommend installing additional insulation where necessary to restore the original R rating.

    Photo 5  
     

    8) No duct
    One or more exhaust fans have no duct and terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should install ducts and vent caps as necessary and as per standard building practices so exhaust air is vented outside. Better building practices call for R8 rated insulation on these ducts.

    Photo 4  
    Both bathroom fans and the dryer vent exhaust into attic
     

     
    Electric service Return to table of contents
    Primary service type: Underground
    Primary service overload protection type: Circuit breakers
    Service voltage (volts): 120/240
    Location of main disconnect: Breaker at top of main service panel
    System ground: Ground rod(s) in soil
    Main disconnect rating (amps): 100
    Branch circuit wiring type: Copper
    Smoke detectors present: Yes
     
    Water heater Return to table of contents
    Estimated age: 2
    Type: Tank
    Energy source: Natural gas
    Capacity (in gallons): 40
     
    Heating and cooling Return to table of contents
    Estimated age: 20
    Primary heating system energy source: Natural gas
    Primary heat system type: Forced air
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Flexible ducts, Metal pipe, Plastic pipe
    Filter location: At the top of the furnace
    9) The heat exchanger in the gas furnace is damaged and/or deteriorated from rust, corrosion, cracking and/or holes. This is a safety hazard due to combustion gases entering the air supply ducts. A qualified heating and cooling contractor should evaluate and make repairs and/or replace components as necessary.

    Photo 19  
     

    10) Significant amounts of debris, dirt and/or dust are visible in one or more sections of supply and/or return air ducts. This can be a health hazard, especially for those with allergies or respiratory problems. The Environmental Protection Association (EPA) recommends considering having ducts professionally cleaned when "ducts are clogged with excessive amounts of dust and debris and/or particles are actually released into the home from your supply registers". At a minimum, the visible debris should be thoroughly cleaned. Recommend having a qualified contractor clean the ducts. For more information on duct cleaning in relation to indoor air quality, visit: http://www.epa.gov/iaq/pubs/airduct.html

    Photo 10  
    Heat Ducts are dirty
     

    11) The estimated useful life for forced air furnaces is 15 to 20 years. This furnace appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    12) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceeded this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    13) The air conditioning system did not respond when its controls were operated. This system was not fully evaluated. The client(s) should consult with the property owner(s) as to how it operates and have a qualified heating and cooling contractor evaluate and make repairs if necessary.

    Photo 14  
    Exhaust blower fan will not turn on, while the other components do.
     

    14) The outside condensing unit is excessively noisy and/or is vibrating excessively. A qualified heating and cooling contractor should evaluate and make repairs as necessary.
    15) The filter(s) for the heating/cooling system should be checked monthly and replaced or washed as necessary.
     
    Plumbing and laundry Return to table of contents
    Water service: Public
    Service pipe material: Copper
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    16) The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

    Photo 15  
    plastic exhausting into attic
     

    17) Dryer vents into the attic
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Fireplace type: Metal prefabricated
    Chimney type: Metal
    18) Tile in front of Fire place, the hearth has tile damage

    Photo 13  
    subfloor below caused tile to crack a heave
     

    19) All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.
     
    Kitchen Return to table of contents

    20) One or more faucets leak by handle(s) or at their base when turned on. A qualified plumber should evaluate and repair as necessary.
    21) The range hood fan vents into the kitchen rather than outdoors. Ventilation may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor make modifications as necessary as per standard building practices so the range hood fan vents outdoors.
     
    Bathrooms Return to table of contents

    22) One or more light fixtures are loose or installed in a substandard way. A qualified contractor or electrician should evaluate and make repairs as necessary so light fixtures are securely mounted and installed in accordance with the manufacturer's installation instructions.

    Photo 17  
    exhaust fan loose from ceiling
     

    23) One or more toilets are loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.

    Photo 11  
    toliet is loose
     

    24) Caulk is missing or deteriorated around the base of one or more bathtub spouts. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall structures.

    Photo 18  
     

    25) Recommend cleaning and sealing grout in countertops now and in the future as necessary to prevent staining and to improve waterproofing.
     
    Interior rooms Return to table of contents

    26) Based on the age of this structure and the appearance of existing smoke alarms, the alarms may be older than 10 years old. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA. For more information, visit this article: NFPA urges replacing home smoke alarms after 10 years.

    Photo 20  
    10 years or older smoke detector
     

    27) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.

    Photo 8  
    No screens
     

    28) One or more deadbolt mechanisms are inoperable or difficult to operate. A qualified contractor should evaluate and repair as necessary.

    Photo 6  
    deadbolt needs ajustment
     

    29) One or more sliding screen doors are difficult to open or close. A qualified contractor should evaluate and repair or replace door(s) as necessary.

    Photo 7  
    Slightly damaged screen, screen not taught, If screen is not fitted tightly or sctreched, this will prevent door from open easily, the door binds.
    Paint needed on apron trim below door
     

    30) One or more air supply registers are damaged and should be replaced where necessary.
    31) Screens in one or more sliding doors are torn or have holes in them. Screens should be replaced where necessary.
    32) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.
    33) Condensation and/or mildew was found around windows. This is typically caused by high levels of moisture indoors coming in contact with cold, exterior surfaces, and can be controlled by heating and ventilation. Recommend the following:

  • Keep multiple windows slightly open in different parts of the house to allow ventilation.
  • Keep bathroom doors closed when showering.
  • Use exhaust fans when showering and cooking.
  • Use heavy curtains to cover and insulate windows.
  • Avoid hanging wet clothes indoors to dry.
  • Use dehumidifiers.
  • Replace single-pane windows (if installed) with multi-pane windows.

    Photo 16  
    keep weep holes in the window clean, and clear
     
     

    Photo 12  
    re-seal grout
     

     
    DHI