| Doyle Home Inspections | |
| Client(s): | Karen Beard |
| Property address: | 1029 Hinswood Dr. Darien, IL |
| Inspection date: | 7/19/2010 |
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
| Safety | Poses a risk of injury or death | |
| Major Defect | Correction likely involves a significant expense | |
| Repair/Replace | Recommend repairing or replacing | |
| Repair/Maintain | Recommend repair and/or maintenance | |
| Minor Defect | Correction likely involves only a minor expense | |
| Maintain | Recommend ongoing maintenance | |
| Evaluate | Recommend evaluation by a specialist | |
| Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp| General information | Return to table of contents |
| Exterior | Return to table of contents |
![]() Photo 3 light is loose and missing a nut
|
![]() Photo 4 siding is damaged
|
![]() Photo 9 Mildew build up below soffit
|
![]() Photo 6 downspout dumps water to close to the foundation
|
![]() Photo 7 dented gutter
|
![]() Photo 5 soil is to close to the siding
|
| Roof | Return to table of contents |
| Garage | Return to table of contents |
![]() Photo 2 Garage door damaged
|
![]() Photo 25 Garage door damaged
|
![]() Photo 26 Garage door damaged
|
| Attic | Return to table of contents |
![]() Photo 14 Some insulation has been removed
|
![]() Photo 12 FYI, bathroom exhausts into the attic
|
| Electric service | Return to table of contents |
| Water heater | Return to table of contents |
| Heating and cooling | Return to table of contents |
![]() Photo 8 clean the AC fins
|
| Plumbing and laundry | Return to table of contents |
![]() Photo 11 No catch pan below washer or hot water tank
|
| Fireplaces, woodstoves and chimneys | Return to table of contents |
![]() Photo 23 fireplace gas starter has been removed, this is fine, but put on a 1/2" cap
|
![]() Photo 24 FYI, this is the shutoff valve for the gas in the fireplace
|
| Kitchen | Return to table of contents |
| Bathrooms | Return to table of contents |
![]() Photo 27 water leaks when faucet is on
|
![]() Photo 28 water leaks below pedestal sink when it is on
|
![]() Photo 29 leaking from faucet on pedestal sink
|
![]() Photo 20 toilet is slightly loose to floor
|
![]() Photo 15 re caulk bath surround and behind the Spout
|
![]() Photo 16 Both Bath tubs drain slowly
|
| Interior rooms | Return to table of contents |
![]() Photo 30 2nd floor smoke detector is older than 10 years old
|
![]() Photo 22 no screen
|
![]() Photo 10 Cracked window frame on front door
|
![]() Photo 19 closet light needs a new bulb or ballast
|
![]() Photo 17 Door sticks, needs to be trimmed/planed
|
![]() Photo 18 1 of 3 Doors sticks, needs to be trimmed/planed
|
![]() Photo 21 small crack in drywall joint on wall
|
![]() Photo 13 Positive attribute: fire/heat sensor hard wired to the fire department
|