Property Inspection Report |
| Client(s): |
A Valued Customer |
| Property address: |
1234 Lovely Lane Somewhere, NC |
| Inspection date: |
Thursday, March 20, 2008 |
This report published on 5/13/2008 7:13:19 PM EDT
View summary page
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Major Defect | Correction likely involves a significant expense |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor Defect | Correction likely involves only a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Crawl space
Kitchen
Bathrooms
Interior rooms
Report number: 20083
Structures inspected: Residence
Type of building: Single family
Age of building: 14 Years
Property owner's name: A Valued Customer
Time started: 8:30AM
Time finished: 1:00PM
Inspection Fee: -0-
Payment method: N/A
Occupied: No
Weather conditions: Cloudy
Temperature: Cool
Ground condition: Damp
Front of structure faces: West
Main entrance faces: West
Foundation type: Crawlspace
Type of building: Single family
1)

This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
Footing material: Not visible
Foundation material: Concrete block, Brick
Apparent wall structure: Wood frame
Wall covering: Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Wood panel, Glass panel
2)


One or more trip hazards were found in sidewalk and/or patio sections due to cracks, settlement and/or heaving. A qualified contractor should evaluate and repair or replace sidewalk and/or patio sections as necessary to eliminate trip hazards.

Photo 25
sidewalk from driveway to front door
|
|
3)

One or more deck ledger boards are nailed to the structure rather than being attached by adequate fasteners. This poses a significant safety hazard since the ledger board(s) may separate from the structure, causing the deck(s) to collapse. A qualified contractor should install lag screws or bolts as per standard building practices to securely attach the ledger board(s) to the structure. For more information on installing deck ledger boards visit: http://www.hometime.com/Howto/projects/decks/deck_4.htm
And for more information on building safe decks in general, visit: http://www.thisoldhouse.com/toh/knowhow/exteriors/article/0,16417,212625,00.html
4)

Insufficient number of through bolts fastening girder to support posts. Two 5/8" galvanized bolts required at each post. Need to have a qualified contractor to evaluate and make necessary repairs and/or replacement.

Photo 4
|
|
5)

Deck girders bearing on ledger board at house; needs its own support post. Three nails are required in ledger under each joist. Need to have a qualified contractor to evaluate and make necessary repairs and/or replacement.

Photo 5
post required under girder at arrow on left and the nails are required in ledger under joist.
|
|
6)

Exterior receptacles served by ground fault GFICI defective. When plugging tester without using tripping mechanism, breaker would trip. This indicates a possible defective GFICI breaker. Recommend having a licensed electrical contractor to evaluate and make necessary repair or replacement.
7)

The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Photo 2
ground is level in some areas in front of house
|
|
8)
Some decking boards loose, damaged, and deteriorated. Need to have a qualified contractor to evaluate and make necessary repairs and/or replacement.

Photo 21
|

Photo 22
|
9)
Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.

Photo 9
Trim around garage door.
|

Photo 19
needs caulking to prevent moisture from penetrating and rusting out lintel
|

Photo 20
Exposed lintel over window on back of house.
|

Photo 23
caulk to prevent water gettig to and rotting sill.
|

Photo 24
Back door
|

Photo 26
Front door.
|
10)
Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 6
|

Photo 7
|
11)
Foundation vent wells loose. Recommend a quailified contractor to make necessary repairs.

Photo 1
|
|
12)
Two or more shutters are coming loose. Recommed a qualified contractor to evaluate and repair.

Photo 28
|
|
13)
Vent jack for down draft vent coming loose from wall. Need to have a qualified contractor repair or replace.

Photo 3
|
|
Roof inspection method: Viewed from ground with binoculars
Roof type: Gable, Hipped
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 14 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
14)

One or more sections of roof flashing are deteriorated and/or rusted. Leaks may occur as a result. A qualified roofing contractor should evaluate and replace flashing where necessary.

Photo 11
Flashing seperated from brick.
|
|
15)
One or more "rubber boot" flashings are damaged or deteriorated and may result in leaks or vermin intrusion. A qualified contractor should replace flashings where necessary.

Photo 14
|

Photo 15
|
16)
Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.

Photo 16
|
|
17)
Several shingles had holes and are lifted up. Need a qualified roofing contractor to make necessary repairs.

Photo 17
Shingle lifed up.
|

Photo 18
Hole in shingle at ridge over garage.
|

Photo 35
Break in ridge cap over bay.
|
|
18)
Trim around front door is starting to deteriorate at the botton where it meets the concrete porch. Recommed having a quailfied contractor to evaluate and repair.

Photo 27
|
|
19)

Handrail in garage is loose. This is a safety hazard. A qualified contractor should make repairs as necessary. For example, installing new fasteners and/or hardware so handrails are securely attached.

Photo 29
|
|
20)

Electrical Box outside of wall in storage room. Need to have an electrical contractor evaluate and make necessary repairs and/or replace.

Photo 30
|
|
21)

Garage Door has excessive water damage and rot on the two lower panels. Door sagging in the middle. Need to have a qualified contractor to make necessary repairs or replace.
Inspection method: Traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass loose fill
Insulation depth: 12"
Insulation estimated R value: 33
Inspection method: Partially traversed
22)
One or more exhaust fans have no duct and terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should install ducts and vent caps as necessary and as per standard building practices so exhaust air is vented outside. Better building practices call for R8 rated insulation on these ducts.

Photo 40
Exhaust vent not connected to bathroom fan.
|

Photo 41
|
23)
Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection .
Viewed as the perimeter of the attic with flashlight.
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: top of box
Service entrance conductor material: Aluminum
System ground: unable to locate
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes
24)
Was unable to locate primary and secondary condesation discharges for aircondition unit in attic. There was located in crawl space a flex pipe ending in that area. You may want ton consider having a Licensed Mechanical contractor evaluate and repair if needed.
Estimated age: 3 years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
Manufacturer: A.O. Smith
Model: 9211678005
Water temperature (degrees Fahrenheit): 115
Estimated age: 14 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air, Gas fireplace or stove
Primary A/C energy source: Natural Gas
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: Ruud
Model: urgg 10e31jkr uaka036jas
Filter location: In return air duct above furnace
Last service date: undetermined
Estimated age: 14 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air, Gas fireplace or stove
Primary A/C energy source: Natural Gas
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: Ruud
Model: urgg 10e31jkr uaka036jas
Filter location: In return air duct above furnace
Last service date: undetermined
25)


The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
26)

The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
27)

The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
28)
Unit for first floor needs flashing reattached to house and caulked. You should have a qualified contractor make necessary repair.

Photo 32
Flashing at outdoor gas pack needs to be secured to house and recaulked.
|
|
29)
The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
30)
Conduit locking nut not properly installed to the outdoor condensor for the upstairs air conditioner. Need to have a qualified HVAC Contractor to make necessary repairs or adjustments.

Photo 33
|
|
Water pressure (psi): 60
Location of main water shut-off valve: In downstairs closet next to bathroom
Location of main water meter: At street beside driveway
Water service: Public
Service pipe material: Not visible
Supply pipe material: Polybutylene
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material:
Water pressure (psi): 60 lbs
Location of main water shut-off valve: In closet beside downstairs bathroom.
Location of main water meter: At street beside driveway.
Water service: Public
Service pipe material: Not visible
Supply pipe material: Polybutylene
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Fireplace type: Masonry
Chimney type: Masonry
Inspection method: Traversed
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: concrete block
Beam material: Solid wood
Floor structure above: Solid wood joists
Vapor barrier present: No
31)


One or more joists are damaged due to non-standard or substandard notching and/or hole boring. Standard building practices specify the following limitations for notching and boring joists:
Notches should not be cut in the middle third of any joist
Notches should not be deeper than 1/6 of the joist depth
Notches should not be deeper than 1/4 of the joist depth at joist ends
Bored holes should not be closer than 2 inches to the edges of the joist
Bored holes should not be wider than 1/3 of the joist depth
A qualified contractor should evaluate and repair as necessary.

Photo 42
|

Photo 45
|
32)
In one area bridging was not nailed . A qualified contractor should repair or relpace.

Photo 43
|
|
33)
Suspicious substance observed on some floor joists. Recommend having a specialist inspect and evaluate.

Photo 44
|
|
34)
The bracket that attaches the dishwasher to the underside of the countertop is loose, missing or installed in a substandard way. Repairs should be made as necessary, such as installing or reinstalling the bracket, and by a qualified contractor if necessary.
35)
Food disposal rubber throat insert missing.

Photo 34
|
|
36)
The oven light is inoperable. Recommend replacing bulb or having repairs made if necessary by a qualified appliance technician.
37)
One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
38)
One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.

Photo 36
|
|
39)

Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.

Photo 39
On back deck
|
|
40)
One or more windows that were built to open, will not open, or open only minimally due to their being painted shut, damaged and/or deteriorated in some way. Repairs should be made as necessary, and by a qualified contractor if necessary so windows open fully, and open and close easily.

Photo 37
|
|
41)
Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.

Photo 38
at deck
|
|
42)
Front entry door will not latch when closed. Recommend a qualified contractor to repair.

Photo 46
|
|
Sig.
Thank you for your business.