View as PDF


CSI Inspection Services

Website: http://www.csihomeinspect.com
Email: csi4inspect@gmail.com
Phone: (909) 732-4824
2798 Shepherd Ln 
San Bernardino, Ca. 92407
Inspector: Frank Bua

 

Property Inspection Report
Client(s): Jesus & Sara Mendoza
Property address: 30300 Pechanga Pkwy
Temecula, Ca 92592
Inspection date: 3/30/2011
This report published on Tuesday, April 05, 2011 9:12:17 PM PDT

View summary page

Your Home Inspection is an objective, visual analysis of the condition the property, and will help you to make an informed decision regarding the home you are purchasing. A Home Inspection is a "SNAP-SHOT IN TIME" showing you the condition of the property at the time of the inspection. Major & minor repairs are identified as well as many positive aspects of the property plus some of the maintenance that may be necessary to keep it in good and functioning condition. Cosmetic conditions are identified for information purposes only, as a courtesy, or if relevant to a repair.
Thank-you for the opportunity to Inspect your Home. Frank Bua-CSI Inspection Services

General Comment: Home was built in 1988 and was in good structural condition. Mechanically, electrical, HVAC were in good condition. Otherwise there were no major defects. Some minor repairs and maintenance were found in various areas. The pool and systems need to be maintained, due to excessive algae. Overall a very nice Home. See full report for more info.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
ReplaceRecommend replacement 
Repair/ReplaceRecommend repairing or replacing 
Repairs Needed.Recommend repair 
MaintainEvaluate, maintain, or repair as needed 
CosmeticRepair or Maintain as desired. 
EvaluateRecommend furthur evaluation 
ServiceableItem or component appears to be in serviceable or working condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
Re-inspection Tuesday 4/5/2011
General Information
Quick Look Index
Plumbing
Electric service
Heating and Cooling
Water Heater
Exterior / Foundation
Exterior/General
Roof
Attic
Garage
Fireplaces, and Chimneys
Grounds
Interior/General
Laundry
Kitchen
Master Bath
Bath 2
Bath 3
Master Bedroom 1
Bedroom 2
Bedroom 3
Living Room
Dining Area
Misc Interior and Halls
Swimming Pool
Swimming Pool Conditions & Equiptment
 
Re-inspection Tuesday 4/5/2011 Return to table of contents

1) Serviceable, Comment - A Re-inspection was was performed on Tuesday 4/5/2011. Water service was turned on. NOTE: Water service was off at the time of the original inspection. Water related fixtures and appliances were re-evaluated. Report was modified to reflect current status of the home, with the Water Service on. No water related issues were determined.

Photo 87  
 
 
General Information Return to table of contents
Report number: 03301101
Time started: 11pm
Time finished: 130pm
Inspector: Frank Bua
Client present for discussion at end of inspection: Yes
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Inspection fee: $225
Payment method: Check
Buildings inspected: 1289 SF SFR W/2 CAR GAR
Age of building(s): 1988
Front of building faces: East
Occupied: No
 
Quick Look Index Return to table of contents

2) Safety, Comment - Top 3 Concerns. See (Section) for more detailed info.

Photo 42  
(Interior General) Smoke Detectors Missing

Photo 59  
(Garage) Firedoor is not self closing.

Photo 27  
(Exterior/General) Loose electrical cable
 
 
Plumbing Return to table of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Water pressure (psi): 80
Location of main water shut-off valve: Left side of Entry
Location of main water meter: Parkway
Location of main fuel shut-off: Gas Meter Right side of Garage
Water service: Public, Private
Service pipe material: Copper
Supply pipe material: Copper, Polybutylene
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
3) Evaluate, Serviceable - Water Shutoff Valve

Photo 4  
 

4) Evaluate, Serviceable - Gas Meter

Photo 12  
 

5) Serviceable - Water Meter. Service was on at time of re-inspection.

Photo 87  
 
 
Electric service Return to table of contents
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Condition: Appeared serviceable
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 100
Service voltage (volts): 120/220
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Copper
System ground: Concrete encased electrode
Main disconnect rating (amps): 100
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
6) Serviceable - Main Service Panel

Photo 11  
 
 
Heating and Cooling Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition: Required repair, replacement and/or evaluation (see comments below)
Estimated age: 1988
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
A/C Manufacturer: Rheem
Model: RAFD-042JBS
Furnace Manufacturer: Rheem
Model: RGDD-08NE
7) Maintain - Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary. Retainer wire may need repair.

Photo 16  
 

8) Serviceable - Furnace

Photo 15  
 

9) Serviceable - A/C Condenser Unit

Photo 83  
 
 
Water Heater Return to table of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition: Appeared serviceable
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: General Electric
Model: SG40T12AVH00
Location of water heater: Garage
Water temperature (degrees Fahrenheit): Normal
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
10) Serviceable - Water Heater

Photo 14  
 

11) Comment - The seller of any real property containing a water heater must certify in writing to a prospective buyer that the water heater has been braced, anchored or strapped to resist falling or horizontal movement due to earthquake motion. The minimum standard for this security is set forth in the California Plumbing Code, which may be more restrictively amended by local or municipal code or ordinance. The certification can be included with the Homeowner’s Guide to Earthquake Safety, in the Real Estate Purchase Contract or Receipt for Deposit, or with the Real Estate Transfer Disclosure Statement.
 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs, exterior stucco and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Wood, Stucco
Condition of foundation and footings: Appeared serviceable
Foundation type: Slab on grade
Foundation material: Poured in place concrete
Footing material: Poured in place concrete
Condition of concrete slab floor(s): Appeared serviceable
12) Maintain, Cosmetic - Some of the painted surfaces in various areas on the back side of the Fascia boards were peeling/failing.

Photo 77  

Photo 78  

13) Maintain, Cosmetic - The stucco appears to have been painted. Touch-up may be required in some areas.

Photo 5  
 

14) Serviceable - Exterior Views

Photo 2  

Photo 85  
 
Exterior/General Return to table of contents

15) Safety, Evaluate - A section of wiring was not terminated. it appeared to be a connection for a portable spa. This is a potential safety hazard due to the risk of shock. Recommend disconnecting at the service panel if not used or terminating in a junction box.

Photo 27  
(Exterior/General) Loose electrical cable
 
 
Roof Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Age of roof surface(s): 1988
Roof inspection method: Partially traversed, Viewed from eaves on ladder
Condition of metal and/or tile roof surface materials: Appeared serviceable Minor Repairs
Metal, tile or panel roof surface material: Concrete tile
Condition of exposed flashings: Appeared serviceable
16) Maintain, Serviceable - Roof Views. There were a few cracked and chipped tiles noted. None that appeared to be causing any leak conditions. Repair or replace as required or desired.

Photo 75  

Photo 81  

Photo 67  

Photo 68  

Photo 69  

Photo 70  

Photo 71  

Photo 72  

Photo 74  

Photo 82  
 
Attic Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Inspection method: Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass roll or batt
Insulation depth: 6"
Insulation estimated R value: R19
17) Maintain, Serviceable - Attic Views. Storage boards were in an impractical location. Recommend removing.

Photo 44  

Photo 45  

18) Serviceable - Attic Access was located in the upstairs hall.

Photo 41  
 
 
Garage Return to table of contents
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
Type: Attached
Condition of Firedoor: Repairs Needed
Type of door: Metal
Condition of Exterior Door: Appeared serviceable
Type of door: Solid core
Condition of garage vehicle door(s): Appeared serviceable
Garage vehicle door type: Sectional
Condition of automatic opener(s): Appeared serviceable
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: Exists
Receptacles Condition: Serviceable
Switches Condition: Serviceable
Lighting Condition: Serviceable
19) Safety, Repair/Replace, Evaluate - The self-closing device on the garage-dwelling door is missing. This door is intended to prevent vehicle fumes from entering living spaces and to slow the spread of fire from the garage to living spaces. A qualified person should evaluate and make repairs as necessary.

Photo 59  
(Garage) Firedoor is not self closing.
 

20) Replace - Broken switch plate was noted by side door.

Photo 76  
 

21) Serviceable - Garage Door

Photo 86  
 

22) Serviceable - Garage Door Opener

Photo 13  
 

23) Serviceable - Garage View

Photo 43  
 
 
Fireplaces, and Chimneys Return to table of contents
Condition of fireplaces, stoves: Appeared serviceable
Fireplace type: Metal prefabricated
Chimney type: Metal
24) Serviceable - Fireplace

Photo 61  
 

25) Serviceable - Chimney

Photo 73  
 
 
Grounds Return to table of contents
Limitations: Some amount of cracking is normal in concrete slabs, exterior stucco and foundation walls due to shrinkage and drying. The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood
Site profile: Minor slope
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable Maintain
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
26) Maintain, Serviceable - Backyard Patio Cover. Painted finish has signs of moderate wear and tear and weathering.
See termite report if available for any wood repairs required or recommended.

Photo 79  

Photo 80  

27) Serviceable - Driveway

Photo 3  
 

28) Serviceable - Yard Views

Photo 1  

Photo 24  

29) Serviceable - Front yard Arbor patio

Photo 6  
 
 
Interior/General Return to table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Metal
Condition: Appeared serviceable
Condition of interior doors: Appeared serviceable
Type of windows: Aluminum
Condition of Windows: Appeared serviceable Varies
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall
Condition of ceilings: Appeared serviceable
Flooring type or covering: Carpet, Laminate
Receptacles Condition: Serviceable
Switches Condition: Serviceable
Lighting Condition: Serviceable
Condition of smoke detectors: Required repair, replacement and/or evaluation (see comments below)
Smoke detectors present: No
Smoke detector power source: Hard wired
30) Safety, Repair/Replace - Smoke detectors were missing from bedrooms, from hallways leading to bedrooms, on one or more levels. Additional smoke detectors should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, in each bedroom, and one each level of the building. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html

Photo 42  
(Interior General) Smoke Detectors Missing
 

31) Repair/Replace, Evaluate - Seals between multi-pane glass in some windows appear to have failed based on condensation or stains between the panes of glass. The view through the window may be obscured. Evaluate and replace glass where necessary.

The client should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too.

Photo 28  
 

32) Repairs Needed. - Patio door screen had minor damage.

Photo 65  
 

33) Maintain, Cosmetic - Carpeting in many areas had was stained. Recommend professional cleaning or replace as desired or required.

Photo 46  

Photo 66  

34) Maintain - Front Entry
1. The weatherstrip around the was damaged, deteriorated.
2. Screen Door screening had minor damage.

Photo 7  

Photo 8  

Photo 9  

Photo 10  
 
Laundry Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: Yes
220 volt receptacle for laundry equipment present: Yes
Receptacles Condition: Serviceable
35) Serviceable - Laundry

Photo 58  
 
 
Kitchen Return to table of contents
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of garbage disposal: Appeared serviceable
Condition of dishwasher: Serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Natural gas
Condition of built: Appeared serviceable
Switches Condition: Serviceable
Receptacles Condition: Serviceable
GFI Protected: No
Lighting Condition: Serviceable
36) Cosmetic, Evaluate - Stain on the laminated flooring at the refrigerator was noted.

Photo 55  
 

37) Serviceable - Sink Area

Photo 52  
 

38) Serviceable - Undersink area and Plumbing

Photo 53  
 

39) Serviceable - Garbage Disposal

Photo 54  
 

40) Serviceable - Stove

Photo 49  
 

41) Serviceable - Microwave

Photo 50  
 

42) Serviceable - Dishwasher

Photo 51  
 

43) Comment - Kitchen View. Recommend Replacing standard outlets with ground fault circuit interupter (GFCI) type. These type of outlets were not required when this home was built. All receptacles within six feet six inches of a sink should have GFCI protection.

Photo 63  
 
 
Master Bath Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Condition of counters: Appeared serviceable
Condition of cabinets: Repiars Needed
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Switches Condition: Serviceable
Receptacles Condition: Serviceable
GFI Protected: Yes
Lighting: Serviceable
44) Repairs Needed., Serviceable - Vanity.
1. Center top drawer guide was damaged.
2. Sink Pop-ups were inoperable or damaged

Photo 29  

Photo 33  

Photo 88  

Photo 89  

45) Serviceable - Tub/Shower

Photo 30  

Photo 31  

46) Serviceable - Toilet

Photo 32  
 
 
Bath 2 Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Switches Condition: Serviceable
Receptacles Condition: Serviceable
GFI Protected: Yes
Lighting Condition: Serviceable
47) Maintain, Serviceable - Tub/Shower. Maintain caulking around spout and control valve.

Photo 37  

Photo 38  

48) Serviceable - Vanity

Photo 47  
 

49) Serviceable - Toilet

Photo 48  
 
 
Bath 3 Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Serviceable
Condition of toilets: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Switches Condition: Serviceable
Receptacles Condition: Serviceable
GFI Protected: Yes
Lighting Condition: Serviceable
50) Serviceable - Vanity

Photo 56  
 

51) Serviceable - Toilet

Photo 57  
 
 
Master Bedroom 1 Return to table of contents
Smoke Detector: No
52) Repairs Needed. - Closet doors were off track and need repairs

Photo 35  
 

53) Serviceable - Master Bedroom

Photo 34  
 
 
Bedroom 2 Return to table of contents
Smoke Detector: No
54) Serviceable - Bedroom 2

Photo 39  
 
 
Bedroom 3 Return to table of contents
Smoke Detector: No
55) Serviceable - Bedroom 3

Photo 40  
 
 
Living Room Return to table of contents

56) Serviceable - Living Room

Photo 60  
 
 
Dining Area Return to table of contents

57) Serviceable - Dining Area

Photo 62  
 
 
Misc Interior and Halls Return to table of contents

58) Serviceable - Halls

Photo 36  
 

59) Serviceable - Stairs

Photo 64  
 
 
Swimming Pool Return to table of contents

60) Maintain, Serviceable - The pool appeared to be in generally good condition. It had a pebble bottom finish. Algae was present likely due to lack of chlorine. See below for more info.

Photo 17  
 
 
Swimming Pool Conditions & Equiptment Return to table of contents
Limitations: The following items are not included in this inspection: swimming pool bodies; equipment on timers, remote controls or sensors; underground or concealed piping; motorized covers; waterfalls and related equipment; Ozone generators; ultraviolate light systems; filter backflushing mechanisms. Any comments made regarding these items are as a courtesy only. Note that the inspector does not disassemble filters, remove pool covers, nor determine if swimming pool bodies, filters or skimmers leak, nor determine if swimming pool bodies are level.
Water level: Full
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood
Condition of body: Appeared serviceable
Body type: Below ground ~
Body material: Plaster-Gunite ~ Pebble Bottom
Condition of deck: Appeared serviceable
Deck material: Concrete, Stone
Coping material: Stone, Concrete
Condition of pumps, lines and valves: Appeared serviceable
Water is refilled through: Not determined
Types of pumps installed: Circulation
Line material: PVC
Condition of heater and related equipment: N/A
Condition of filter and related equipment: Maintain
Filter type: Cartridge
Filter air relief valve installed: Yes
Filter pressure gauge installed: Yes
Filter pressure at time of inspection (psi): 40
Condition of skimmers: Appeared serviceable
Condition of electrical equipment: Appeared serviceable
Location of electrical disconnect: In main service panel, In sub-panel at equipment
Type of wiring: Liquid Tite Flex
61) Repairs Needed., Maintain, Evaluate - Filter.
1. The reading at the cartridge filter's pressure gauge was relatively high. (40lbs). Cartridge filters should be cleaned when the pressure gauge reads 8 lbs or more above the clean, starting pressure (after cleaning or replacing cartridge). A qualified person should clean or replace cartridge(s) as necessary, and make repairs if necessary.
2. Leaks or evidence of leaks were found at the filter gasket, O-ring. A qualified contractor should evaluate and repair as necessary.

Photo 19  

Photo 22  

62) Maintain, Evaluate - Algae was present on the pool surface. It's best to prevent algae from growing in the first place, but once it does, typical remedies include:

  • Balancing the water, especially the pH.
  • Checking the filter system and maintaining if necessary (backwash or replace medium, clean or replace cartridge, etc.)
  • Running the filter system continuously until the water clears
  • "Shocking" the pool with hypochlorite
  • Brushing the walls and floor of the pool
  • Draining the pool (in extreme cases)
  • Applying an algaecide

    The presence of algae may indicate lack of chlorine or filter system needs maintaining. or both. Recommend consulting with a pool specialist if needed. For more information, visit:
    http://www.poolcenter.com/algae.htm

    Photo 26  
     

    63) Evaluate - Auto Chlorinator was empty.

    Photo 20  
     

    64) Serviceable - Circulation Pump

    Photo 18  
     

    65) Serviceable - Electrical Control Panel.

    Photo 21  
     

    66) Comment - Equipment view. See above items.

    Photo 25  
     

    67) Comment - Unknown type of pool equiptment was noted. Buyer may want to inquire with owner or pool specialist for more info

    Photo 23  
     

     
    General Disclaimer: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components.