Cottages & Castles Home Inspection, Inc.
Website: http://www.reporthost.com/cottagesandcastles
Email: cottages-castles@comcast.net
Phone: (847) 973-2504
FAX: (847) 973-2508
508 Deer Run
Spring Grove, Illinois 60081
Inspector: Brian Flynn Ill Lic No:0002955
|
HOME INSPECTION REPORT |
| Client(s): |
Brian & Kim Flynn |
| Property address: |
508 Deer Run Spring Grove Ill. 60081 |
| Inspection date: |
Friday January 27, 2006 |
This report published on 1/28/2006 2:51:45 PM CST
View summary page
Illinois License No: 050.0002955
Thank you for allowing Cottages & Castles Home Inspection the opportunity to conduct a professional inspection of your prospective new home.
The inspection and report are performed and prepared for the sole, confidential and exclusive use and possession of the Client(s) only. Information from this report is not for use or to be relied upon by any third party. Receipt of this report by any purchasers of the property (other than the above listed Client) is strictly prohibited. Duplication by any means is prohibited without prior written permission from Cottages & Castles Home Inspection.
Inspectors are generalists, not acting as experts in any craft or trade, and are conducting what is essentially a visual inspection. Home Inspectors generally know something about everything and specialize in little. If your inspector recommends consulting specialists or experts, you the Client agree to do so at your own expense. Because such qualified personnel are experts, it is possible that they will discover additional problems that a home inspector cannot.
This should be expected, as an example, if it is discovered that one electrical receptacle has reversed polarity, the odds dictate that others may exist in areas we could not access.
It is recommended that any deficiencies and the components/systems related to these deficiencies noted in this report be evaluated/inspected and repaired as needed by a licensed contractor/professional prior to the close of escrow.
This is the report of a visual inspection of the readily accessible areas of this home, in accordance with the terms and conditions contained within the Home Inspection Agreement, and within the Standards of Practice listed at http://www.nachi.org/sop.htm as well as the licensing standards set forth by the State of Illinois. These standards list items to be described in this report and items to be observed or evaluated during a home inspection.
Home inspection reports generally focus on defects and may seem negative in tone. Some features of this property may be in excellent condition and of high quality but have not been included in the report. This is not meant to downplay this property's assets, but to focus on alerting you to potentially costly problems.
Maintenance and other items may be discussed, but they are not a part of our inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind.
NACHI STANDARDS of PRACTICE
Table of Contents
1. Definitions and Scope.
2. Standards of Practice
2.1. Roof
2.2. Exterior
2.3. Basement, Foundation, Crawlspace & Structure
2.4. Heating
2.5. Cooling
2.6. Plumbing
2.7. Electrical
2.8. Fireplace
2.9. Attic & Insulation
2.10. Doors, Windows & Interior
3. Limitations, Exceptions & Exclusions
4. Glossary of Terms
1. Definitions and Scope
1.1. A Home inspection is a non-invasive visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to or during the inspection process.
I. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection and not the determination of future conditions.
II. A home inspection will not reveal every problem that exists or ever could exist, but only those material defects observed on the day of the inspection.
1.2. A Material defect is a problem with a residential real property or any portion of it that would have a significant adverse impact on the value of the property or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect.
1.3. An Inspection report shall describe and identify in written format the inspected systems, structures, and components of the dwelling and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals.
2. Standards of Practice
2.1. Roof
I. The inspector shall inspect from ground level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other roof penetrations.
E. The general structure of the roof from the readily accessible panels, doors or stairs.
II. The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces.
E. Inspect antennae, lightning arresters, or similar attachments.
2.2. Exterior
I. The inspector shall inspect:
A. The flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs, porches, railings, eaves, soffits, fascias, grading, and walkways.
C. And report as in need of repair any spacings between intermediate balusters, spindles, or rails for steps, stairways, balconies, and railings that permit the passage of an object greater than four inches in diameter.
D. The vegetation, surface drainage and retaining walls when these are likely to adversely affect the building.
E. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not visible or readily accessible from the ground.
C. Inspect geological, geotechnical, or hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged glass.
2.3. Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or indications of active water penetration by probing a representative sampling of structural components where deterioration is believed to be present or where clear indications of deterioration are present.
F. And report any general indications of foundation movement that are observed, such as but not limited to sheetrock cracks, brick cracks, out-of-square door frames or floor slopes.
II. The inspector is not required to:
A. Enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector in his or her opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or adequacy of foundation bolting, bracing, joists or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.
2.4. Heating
I. The inspector shall inspect:
A. The heating system and describe the energy source and heating method using normal operating controls.
B. And report as in need of repair electric furnaces which do not operate.
C. And report if inspector deemed the furnace inaccessible.
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues or chimneys, fire chambers, the heat exchanger, the humidifier or dehumidifier, the electronic air filter, solar heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system.
D. Light pilot flames.
E. Activate heating, heat pump systems, or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment using normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system.
B. Inspect window units, through-wall units, or electronic air filters.
C. Operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit or when other circumstances are not conducive to safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration, heat anticipation or automatic setbacks or clocks.
E. Examine electrical current, coolant fluids or gasses, or coolant leakage.
2.6. Plumbing
I. The inspector shall:
A. Inspect the main water shut off valve.
B. Inspect the water heating equipment, including combustion air, venting, connections, energy sources, seismic bracing, and verify the presence or absence of temperature-pressure relief valves and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all fixtures and faucets.
F. Inspect the drain, waste and vent systems, including all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps testing sumps with accessible floats.
I. Inspect and describe the water supply, drain, waste and main fuel shut-off valves, as well as the location of the water main and main fuel shut-off valves.
J. Inspect and determine if the water supply is public or private.
K. Inspect and report as in need of repair deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies in installation and identification of hot and cold faucets.
M. Inspect and report as in need of repair mechanical drain-stops that are missing or do not operate if installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes that have cracks in the ceramic material, are improperly mounted on the floor, leak, or have tank components which do not operate.
II. The inspector is not required to:
A. Light pilot flames.
B. Determine the size, temperature, age, life expectancy or adequacy of the water heater.
C. Inspect interiors of flues or chimneys, water softening or filtering systems, well pumps or tanks, safety or shut-of valves, floor drains or sprinkler systems.
D. Determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply.
E. Determine the water quality or potability or the reliability of the water supply or source.
F. Open closed plumbing access panels.
G. Inspect clothes washing machine connections.
H. Operate any main, branch or fixture valve except fixture faucets and hose faucets attached to the building.
I. Test shower pans, tub and shower surrounds or enclosures for leakage.
J. Evaluate the compliance with local or state conservation or energy standards, or the proper design or sizing of any water, waste or venting components, fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices.
L. Determine whether there are sufficient clean-outs for effective cleaning of drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Excavate or otherwise uncover the private sewage system or its components to determine size, adequacy or efficiency.
O. Inspect water treatment systems or water filters.
P. Inspect pressure pumps or bladder tanks.
Q. Evaluate time to obtain hot water at fixtures, or perform testing of any kind to water heater elements.
R. Evaluate or determine the adequacy of combustion air.
S. Test, operate, open or close Watts 210 valves and/or TPR valves.
T. Examine ancillary systems or components, such as, but not limited to, those relating to solar water heating, hot water circulation.
2.7. Electrical
I. The inspector shall inspect:
A. The service line.
B. The meter box.
C. The main disconnect.
D. And determine the service amperage.
E. Panels, breakers and fuses.
F. The grounding.
G. The bonding.
H. A representative sampling of switches, receptacles, light fixtures, and test all GFCI receptacles and GFCI circuit breakers observed and deemed to be GFCI's during the inspection.
I. And report the presence of solid conductor aluminum branch circuit wiring if readily visible.
J. And report on any GFCI-tested receptacles in which power is not present, polarity is incorrect, the receptacle is not grounded, is not secured to the wall, the cover is not in place, the ground fault circuit interrupter devices are not properly installed or do not operate properly, or evidence of arcing or excessive heat is present.
K. The service entrance conductors and the condition of their sheathing.
L. The ground fault circuit interrupters with a GFCI tester.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need of repair deficiencies in the integrity of the insulation, drip loop, or separation of conductors at weatherheads and clearances.
II. The inspector is not required to:
A. Insert any tool, probe or device into the main or sub-panels.
B. Operate electrical systems that are shut down.
C. Remove panel covers or dead front covers if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service if not visibly labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems or branch circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring or any time-controlled devices.
L. Verify the continuity of the connected service ground.
M. Inspect private or emergency electrical supply sources, including but not limited to generators, windmills, photovoltaic solar collectors, or battery or electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct drop voltage calculations.
P. Determine the accuracy of breaker labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close the damper door if readily accessible and operable.
B. Hearth extensions and other permanently installed components.
C. And report as in need of repair deficiencies in the lintel, hearth and material surrounding the fireplace, including clearance from combustible materials
II. The inspector is not required to:
A. Inspect the vent system.
B. Inspect the interior of the chimney or flue, fire doors or screens, seals or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion make up devices.
I. Inspect heat distribution assists whether gravity controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or remove any component.
2.9. Attic, Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
II. The inspector is not required to:
A. Enter the attic or unfinished spaces that are not readily accessible or where entry could cause damage or pose a safety hazard to the inspector in his or her opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the surface finish or weather seal on or around access panels and covers.
E. Identify the composition or the exact R-value of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation/wrapping of pipes, ducts, jackets, boilers, and wiring.
2.10. Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative number of doors and windows.
B. Inspect the walls, ceilings, steps, stairways, and railings.
C. Inspect garage doors and garage door openers by operating first by remote (if available) and then by the installed automatic door control.
D. And report as in need of repair any installed electronic sensors that are not operable or not installed at proper heights above the garage door.
E. And report as in need of repair any door locks or side ropes that have not been removed or disabled when garage door opener is in use.
F. And report as in need of repair any windows that are obviously fogged or display other evidence of broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in locations subject to human impact.
D. Inspect security components.
E. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or firewall compromises.
F. Move furniture, stored items, or any coverings like carpets or rugs in order to inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed in the garage except as otherwise noted.
J. Verify or certify safe operation of any auto reverse or related safety function of a garage door.
K. Operate or evaluate security bar release and opening mechanisms, whether interior or exterior, including compliance with local, state, or federal standards.
L. Operate any system, appliance or component that requires the use of special keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles or signal lights.
N. Determine leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed pool/spa or self-contained equipment.
U. Come into contact with any pool or spa water in order to determine the system structure or components.
V. Determine the adequacy of spa jet water force or bubble effect.
W. Determine the structural integrity or leakage of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically exhaustive.
II. An inspection will not identify concealed or latent defects.
III. An inspection will not deal with aesthetic concerns or what could be deemed matters of taste, cosmetic, etc.
IV. An inspection will not determine the suitability of the property for any use.
V. An inspection does not determine the market value of the property or its marketability.
VI. An inspection does not determine the advisability or inadvisability of the purchase of the inspected property.
VII. An inspection does not determine the life expectancy of the property or any components or systems therein.
VIII. An inspection does not include items not permanently installed.
IX. These Standards of Practice apply only to homes with four or fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments.
B. The condition of any component or system that is not readily accessible.
C. The service life expectancy of any component or system.
D. The size, capacity, BTU, performance, or efficiency of any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement of any system or component.
G. Future conditions.
H. The compliance with codes or regulations.
I. The presence of evidence of rodents, animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including, but not limited to, the presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance with manufacturer installation or any information included in the consumer protection bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of how much it will cost to run any given system.
II. The inspectors are not required to operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use of normal operating controls.
E. Any shut off valve.
F. Any electrical disconnect or over current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar equipment.
III. The inspectors are not required to:
A. Move any personal items or other obstructions, such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any system or component.
C. Enter or access any area which may, in the opinion of the inspector, to be unsafe or risk personal safety.
D. Enter crawlspaces or other areas that are unsafe or not readily accessible.
E. Inspect underground items such as, but not limited to, underground storage tanks or other indications of their presence, whether abandoned or actively used.
F. Do anything which, in the inspector's opinion, is likely to be unsafe or dangerous to the inspector or others or damage property, such as, but not limited to, walking on roof surfaces, climbing ladders, entering attic spaces or negotiating with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit housing.
I. Inspect intercoms, speaker systems, radio-controlled, security devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service other than home inspection.
M. Research the history of the property, report on its potential for alteration, modification, extendibility, or its suitability for a specific or proposed use for occupancy.
N. Determine the age of construction or installation of any system structure, or component of a building, or differentiate between original construction or subsequent additions, improvements, renovations or replacements thereto.
O. Determine the insurability of a property.
4. Glossary of Terms
4.1. Accessible: Can be approached or entered by the inspector safely, without difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or enable systems, equipment, or devices to become active by normal operating controls. Examples include turning on the gas or water supply valves to the fixtures and appliances and activating electrical breakers or fuses.
4.3. Adversely Affect: Constitute, or potentially constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices, installed or free-standing, including but not limited to: Carbon monoxide detectors, flue gas and other spillage detectors, security equipment, ejector pumps and smoke alarms.
4.5. Appliance: A household device operated by use of electricity or gas. Not included in this definition are components covered under central heating, central cooling or plumbing.
4.6. Architectural Service: Any practice involving the art and science of building design for construction of any structure or grouping of structures and the use of space within and surrounding the structures or the design, design development, preparation of construction contract documents, and administration of the construction contract.
4.7. Component: A permanently installed or attached fixture, element or part of a system.
4.8. Condition: The visible and conspicuous state of being of an object.
4.9. Crawlspace: The area within the confines of the foundation and between the ground and the underside of the lowest floor structural component.
4.10. Decorative: Ornamental; not required for the operation of essential systems and components of a home.
4.11. Describe: Report in writing a system or component by its type, or other observed characteristics, to distinguish it from other components used for the same purpose.
4.12. Determine: To arrive at an opinion or conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or remove any component, device or piece that would not typically be opened, taken apart or removed by an ordinary occupant.
4.14. Engineering Service: Any professional service or creative work requiring engineering education, training, and experience and the application of special knowledge of the mathematical, physical and engineering sciences to such professional service or creative work as consultation, investigation, evaluation, planning, design and supervision of construction for the purpose of assuring compliance with the specifications and design, in conjunction with structures, buildings, machines, equipment, works or processes.
4.15. Enter: To go into an area to observe all visible components.
4.16. Evaluate: To assess the systems, structures or components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the structure or wall rests; usually masonry, concrete, or stone, and generally partially underground.
4.19. Function: The action for which an item, component, or system is specially fitted or used or for which an item, component or system exists; to be in action or perform a task.
4.20. Functional: Performing, or able to perform, a function.
4.21. Home Inspection: The process by which an inspector visually examines the readily accessible systems and components of a home and operates those systems and components utilizing these Standards of Practice as a guideline.
4.22. Household Appliances: Kitchen and laundry appliances, room air conditioners, and similar appliances.
4.23. Inspect: To visually look at readily accessible systems and components safely, using normal operating controls and accessing readily accessible panels and areas.
4.24. Inspected Property: The readily accessible areas of the buildings, site, items, components, and systems included in the inspection.
4.25. Inspector: One who performs a real estate inspection.
4.26. Installed: Attached or connected such that the installed item requires tool for removal.
4.27. Material Defect: Refer to section 1.2.
4.28. Normal Operating Controls: Devices such as thermostats that would be operated by ordinary occupants which require no specialized skill or knowledge.
4.29. Observe: To see through visually directed attention.
4.30. Operate: To cause systems to function or turn on with normal operating controls.
4.31. Readily Accessible: An item or component is readily accessible if, in the judgment of the inspector, it is capable of being safely observed without movement of obstacles, detachment or disengagement of connecting or securing devices, or other unsafe or difficult procedures to gain access.
4.32. Recreational Facilities: Spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment or athletic facilities.
4.33. Report: A written communication (possibly including digital images) of any material defects seen during the inspection.
4.34. Representative Number: A sufficient number to serve as a typical or characteristic example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged, inactive, not in service, not operational, etc.
4.37. Structural Component: A component which supports non-variable forces or weights (dead loads) and variable forces or weights (live loads).
4.38. System: An assembly of various components to function as a whole.
4.39. Technically Exhaustive: A comprehensive and detailed examination beyond the scope of a real estate home inspection which would involve or include, but would not be limited to: dismantling, specialized knowledge or training, special equipment, measurements, calculations, testing, research, analysis or other means.
4.40. Unsafe: A condition in a readily accessible, installed system or component which is judged to be a significant risk of personal injury during normal, day-to-day use. The risk may be due to damage, deterioration, improper installation or a change in accepted residential construction standards.
4.41. Verify: To confirm or substantiate.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
 | Safety | Poses a risk of injury or death |
 | Major defect | Correction likely involves a significant expense |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor defect | Correction likely involves only a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Comment | For your information |
Concern items are sorted by the types listed above. Click here for a glossary of building construction terms. Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Table of Contents
General information
Exterior
Roof
Attached garage
Electric service
Water heater
Heating and air conditioning
Attic
Plumbing and laundry
Basement
Fireplaces and solid fuel burning appliances
Crawl space
Well
Interior rooms
Structures inspected: Home & Detached Shed
Time started: 1:45 Pm
Time finished: 4:35 Pm
Inspection Fee: $355.00
Present during inspection: Owner
Occupied: Yes
Age of building: 13 years
Type of building: Single family
Weather conditions: Partly cloudy
Temperature: Cool 37 Degrees
Ground condition: Frozen
Main entrance faces: North
Foundation type: Unfinished basement, Crawlspace
The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court
 |
1) Numerous wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items, preventing a full evaluation of some areas.
|
Footing material: Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Wood clapboard
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel, Glass panel
   |
2) Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is not adequate and should be updated. Recommend either removing extension cords or having a qualified, licensed electrician evaluate and make modification as necessary. For example, install additional circuits and/or electric outlets.
|
  |
3) One or more trip hazards were found in the driveway due to cracks and/or settlement. Recommend having a qualified paving contractor repair or replace driveway section(s) as necessary to eliminate trip hazards.
|
  |
4) One or more exterior electric receptacles are being used for appliances or systems that are constantly in use, and are not equipped with "in-use" receptacle covers for wet locations. This is a safety hazard due to the risk of shock and fire. "In use" covers should be installed where necessary.
|
 |
5) One or more large trees are very close the foundation. Tree roots can cause significant structural damage to foundations. Recommend having a qualified tree service company remove trees as necessary to prevent damage to the structures foundation.
|
 |
6) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structures foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend making repairs as necessary such as repairing or installing splash blocks or tie-ins to underground drain lines so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
|
 |
7) Minor cracks (1/8" or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration. Numerous products exist to seal such cracks including: Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example. Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example. Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
|
 |
8) Soil is in contact with or less than 6" from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Recommend grading soil as necessary so there's at least 6" of space between the siding and trim and the soil below.
|
 |
9) Vegetation (trees, shrubs and/or vines) are in contact with the structures exterior. This is a conducive condition for wood destroying insects and organisms. Vegetation can serve as a conduit for insects and may retain moisture against the exterior after it rains. Recommend pruning or removing vegetation as necessary so there's at least a one foot gap between all vegetation and the structures exterior.
|
 |
10) Minor cracks were found in the driveway. These are only a cosmetic concern and no action is recommended.
|
 |
11) Minor cracks were found in the sidewalk. These are only a cosmetic concern and no action is recommended.
|
  |
12) One or more composition shingles are damaged, deteriorated and/or missing, and should be replaced. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary.
|
  |
13) Roofing nails in one or more areas have loosened or backed out. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails and applying sealant.
|
Roof inspection method: Viewed from eaves on ladder, Viewed from ground with binoculars
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 13 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
 |
14) The siding on one or more exterior walls above lower roof section(s) is in contact with or has less than a 1" gap between it and the roof surface below. A gap of at least 1" is recommended so water isn't wicked up into the siding from the shingles below, and also to provide room for additional layers of roofing materials when the current roof fails. Recommend having a qualified contractor make repairs (trim siding) so at least a 1" gap exists between the siding and the roofing below where necessary.
|
 |
15) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris is more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Recommend pruning trees so they're at least 10 feet above roof, or don't overhang the roof.
|
   |
16) Evidence of "light to moderate" rodent infestation was found in one or more areas. The Center for Disease Control (CDC) defines this as less than 20 feces per square foot. Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.
Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hanta virus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The clients may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygenist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).
|
  |
17) The garage-house door isn't equipped with an automatic door closing device such as sprung hinges. This door should close and latch automatically to prevent vehicle fumes from entering living spaces and/or to slow the spread of fire from the garage to living spaces. A device should be installed so this door closes and latches automatically.
|
 |
18) The interior perimeter of the garage is excluded from this inspection due to lack of access from stored items.
|
Inspection method: Traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass roll or batt
Insulation depth: 10"
Insulation estimated R value: 30
   |
19) Combustibles such as wood or insulation are in contact with or less than one inch from chimney or gas flue pipes in one or more areas. This is a fire hazard. A qualified contractor should evaluate and make repairs or modifications as necessary so minimum clearances to combustibles are maintained around all chimney and flue pipes as per the manufacturer's specifications.
|
   |
20) Recessed "can" lights are installed in the ceiling below the attic. The inspector was unable to find a label or markings that indicated if these lights are designed to be in contact with insulation, and one or more lights are in contact with insulation. This is a possible fire hazard. Further evaluation should be performed, by a qualified contractor if necessary, to determine if these lights are rated for contact with insulation. If they aren't, or if their rating can't be determined, insulation should be moved, and wells or barriers should be installed or repaired as necessary to keep the insulation away from these lights.
|
 |
21) One or more exhaust fans have no duct and terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should install ducts and vent caps as necessary and as per standard building practices so exhaust air is vented outside. Better building practices call for R8 rated insulation on these ducts.
|
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120-240
Location of main service panel: center of north wall in basement
Location of main disconnect: Breaker at top of main service panel
Service conductor material: Copper
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes
Estimated age: 13 years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Brand & model: RHEEM 21v40-7
Water temperature (degrees Fahrenheit): 130 degrees
  |
22) Hot water temperature greater than 120 degrees Fahrenheit. Recommend adjusting thermostat so water temperature doesn't exceed 120 degrees to avoid scalding danger. For more information on scalding dangers, visit http://www.tap-water-burn.com/
|
  |
23) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older. Recommend budgeting for a replacement in the near future.
|
Heating system energy source: Natural gas
Heat system type: Forced air, High efficiency, Gas fireplace or stove
A/C energy source: Electric
Air conditioning type: Split system
Distribution system: Sheet metal ducts
Brand & model: Tempstar NUG100DH11
Filter location: At the base of the furnace
   |
24) Because of the age and/or condition of this furnace, recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
|
  |
25) The estimated useful life for forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time.
|
  |
26) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to be approaching this age and may need replacing at any time.
|
  |
27) Last service date of this system is more than one year ago or is unable to be determined. Recommend asking seller when it was last serviced. If unable to determine or if more than one year ago, recommend that this system be inspected, cleaned, serviced and repaired if necessary by a qualified heating and cooling technician. Recommend that this servicing be made annually in the future or as recommended by the heating and cooling contractor.
|
 |
28) Recommend that this system be inspected, cleaned, serviced and repaired if necessary by a qualified heating and cooling technician annually in the future.
|
 |
29) This system is equipped with mechanical pleated filter(s). Recommend replacing them every 7 to 12 months in the future if the thermostat's fan position is set to "Auto", or monthly if it's set to "On".
|
 |
30) Outdoor air temperature below 60 degrees Fahrenheit, unable to operate and/or fully evaluate cooling system.
|
Inspection method: Partially traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglas roll or batt
   |
31) Recessed "can" lights are installed in the ceiling below the attic. The inspector was unable to find a label or markings that indicated if these lights are designed to be in contact with insulation, and one or more lights are in contact with insulation. This is a possible fire hazard. Recommend trying to determine if these lights are rated for contact with insulation. If they aren't, or if their rating can't be determined, recommend repairing or installing barriers to keep insulation away from these lights and moving or removing insulation as necessary.
|
 |
32) One or more exhaust fan ducts terminate in attic rather than at a vent cap in the roof or exterior wall. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should make repairs as necessary, such as installing vent cap(s) where necessary and securely attaching the duct(s), so the exhaust air is vented outside.
|
 |
33) No weatherstrip is installed around the attic access hatch. Recommend installing weatherstrip around hatch to prevent heated interior air from entering attic.
|
  |
34) One or more active leaks were found in drain and/or waste pipes or fittings. A qualified plumber should evaluate and repair as necessary.
|
Location of main water shut-off valve: northeast side of east wall in basement
Location of main fuel shut-off: northeast side of north exterior wall at gas meter
Water service: Private
Service pipe material: Copper
Supply pipe material: plastic
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
  |
35) The clothes dryer is equipped with a plastic (vinyl) or foil, accordion-type, flexible duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. The flexible plastic or foil type duct can more easily trap lint and is more susceptible to kinks or crushing, which can greatly reduce the airflow. Recommend replacing the duct with a rigid or corrugated semi-rigid metal duct. Most manufacturers specify the use of a rigid or corrugated semi-rigid metal duct, which provides maximum airflow. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
|
   |
36) Water pressure is below 40 psi, but the flow appeared to be adequate. 40-80 psi is considered to be the normal range for water pressure in a home. The inspector performed a "functional flow test" during the inspection, where multiple fixtures are run simultaneously, and found there to be adequate flow. For example, the shower flow didn't decrease significantly when the toilet was flushed.
If the client finds the flow to be inadequate, recommend having a qualified plumber evaluate and repair as necessary. Installing a pressure boosting system is one possible solution. For information on these systems, visit: http://www.low-water-pressure.com/
|
  |
37) Recommend having septic tank inspected. Recommend pumping tank if last pumped more than 3 years ago.
|
Pier or support post material: Steel
Beam material: Steel
Floor structure above: Solid wood joists
   |
38) Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is not adequate and should be updated. Recommend either removing extension cords or having a qualified, licensed electrician evaluate and make modification as necessary. For example, install additional circuits and/or electric outlets.
|
   |
39) Evidence of "light to moderate" rodent infestation was found in one or more areas. The Center for Disease Control (CDC) defines this as less than 20 feces per square foot. Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.
Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hanta virus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The clients may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygenist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).
|
Fireplace type: Metal prefabricated
Chimney type: Metalflue insert
   |
40) A significant amount of creosote (1/8" or more) visible in fireplace flue. Recommend cleaning, inspection and repairs if necessary by a qualified chimney service contractor.
|
 |
41) One or more refractory panels (the 1" thick fireproof panels lining the fireplace walls) are cracked and need repairing. Recommend patching cracks with a high temperature resistant refractory mortar or sealant available at hardware stores. Recommend monitoring the refractory panels in the future. This type of repair will likely need repeating. Recommend replacing refractory panels if cracks exceed 1/4" in width, if surface pitting becomes extensive and deeper than 3/16", or if any piece of the refractory larger than 2"(51 mm) in radius and 3/16" deep becomes dislodged.
|
 |
42) Significant amounts of ashes, wood and/or debris are in the fireplace. The inspector was unable to fully evaluate it.
|
Inspection method: Traversed
Floor structure above: Solid wood joists
   |
43) Evidence of "light to moderate" rodent infestation was found in one or more areas. The Center for Disease Control (CDC) defines this as less than 20 feces per square foot. Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.
Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hanta virus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The clients may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygenist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).
|
| |
44) crawlspace has concrete floor & is heated , rim joist is insulated
|
Location of well equipment: northeast side of east wall in basement
Location of tank shut off valve: northeast side of east wall in basement
  |
45) The well casing is less than 12" above the ground. Recommend grading soil so there's at least 12" from the top of the well casing to the ground to reduce the chance of contaminants entering the well.
|
  |
46) Recommend having the well water tested for bacteria by a qualified lab.
|
  |
47) The estimated life for a submersible pump is 20 years. This well pump may be nearing the end of its estimated useful life. The clients should be aware that this pump may need replacing at any time.
|
  |
48) Handrail(s) are missing from one or more flights of stairs with more than two risers. This is a safety hazard. Recommend having a qualified contractor install graspable handrails that your hand can completely encircle at stairs with more than two risers where missing.
|
  |
49) The doorbell appeared to be inoperable at the time of inspection. Recommend that a qualified electrician evaluate and repair as necessary.
|
  |
50) Walking on some sections of the floor results in squeaking or creaking noises. This is usually the result of substandard construction practices where the subfloor decking isn't adequately fastened (insufficient glue) to the framing below. In most cases, this is an annoyance only rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on there being finished hardwood floors, carpeting over the subfloor, and/or clear access to the underside of the subfloor. Recommend having a qualified contractor evaluate and repair as necessary.
|
 |
51) Screen(s) missing in one or more windows. Window(s) may not provide ventilation during months when insects are active. Recommend installing screens.
|
 |
52) Screen(s) torn in one or more windows. Window(s) may not provide ventilation during months when insects are active. Recommend repairing or replacing screens.
|
 |
53) No exhaust fan is installed in the laundry room. This can lead to excessive accumulation of moisture. Recommend having a qualified contractor install an exhaust fan with a timer, duct and vent cap as per standard building practices in the laundry room.
|
 |
54) Fixtures such as door stops, towel bars and/or toilet paper holders are missing and damaged or deteriorated in one or more areas. Recommend having a qualified contractor install fixtures where missing and replace or repair fixtures as necessary.
|
 |
55) Minor cracks found in ceiling. These are only a cosmetic concern. No action is recommended.
|
 |
56) Minor cracks found in walls. These are only a cosmetic concern. No action is recommended.
|
  |
57) Based on the age of this structure and the appearance of existing smoke alarms, the alarms may be older than 10 years old. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA. For more information, visit this article: NFPA urges replacing home smoke alarms after 10 years.
|
  |
58) An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
|
  |
59) Lamp holders or light fixtures with fully or partially exposed bulbs are installed in one or more closets. This is a safety hazard due to the risk of fire. Flammable stored items may come into contact with hot bulbs, and hot fragments from broken bulbs may fall on combustible materials. Standard building practices require closet lighting to use fluorescent light fixtures, or to use fully enclosed incandescent fixtures. Installing a compact fluorescent lamp in a lamp holder is not an acceptable practice. A qualified electrician should replace closet lights as necessary and as per standard building practices.
|
  |
60) Gaps larger than four inches were found in one or more guardrails. This is a safety hazard, especially for small children. A qualified contractor should make modifications as necessary so gaps in guardrails do not exceed four inches. For example, installing additional balusters or railing components.
|
Thank You for allowing Cottages & Castles provide you with this report, I trust that the information outlined will be beneficial. If you have any questions regarding portions of this report, Please feel free to contact me at 1-847-973-2504