Website: http://www.corehomeinspections.com
Email: coreinspector282@yahoo.com
Phone: (405) 408-2944
1631 N. Orchard Terrace 
Mustang, OK 73064
Inspector: Billy Clark

 

Home Inspection Report
Client(s): John Doe
Property address: 1234 Nowhere Dr.
Anywhere, OK 54321
Inspection date: Monday, November 07, 2005
This report published on 11/7/2005 4:27:43 PM CST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.


How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
SafetyPotential safety hazard 
Major defectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a licensed technician 
CommentFor your information 
Concern items are sorted by the types listed above.  Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms


General information Return to table of contents  
Report number: 11072005-345
Structures inspected: 1234 Nowhere Dr. Anywhere, OK 54321
Type of building: Single family
Age of building: 1975
Property owner's name: John and Salley Deere
Time started: 3:00 p.m.
Time finished: 5:15 p.m.
Inspection Fee: $545.00
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm, 80 degrees
Ground condition: Dry
Front of structure faces: South
Main entrance faces: South
Foundation type: Slab on grade
The following items are excluded from this inspection: Private sewage disposal system, Water filtration system, Built-in sound system, Sport court
1) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygenists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
  •  
    Exterior Return to table of contents  
    Footing material: Poured in place concrete
    Foundation material: Poured in place concrete
    Apparent wall structure: Wood frame
    Wall covering: Brick veneer, Wood siding
    Driveway material: Poured in place concrete
    Sidewalk material: Poured in place concrete
    Exterior door material: Solid core wood, Glass panel
    2) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

    Photo 1  
     
     
    Roof Return to table of contents  
    Roof inspection method: Traversed
    Roof type: Gable
    Roof covering: Asphalt shingles
    Estimated age of roof: 12 yrs.
    Gutter & downspout material: Aluminum
    Roof ventilation: Adequate
    3) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.
     
    Garage Return to table of contents  
    4) Flexible lamp or appliance cord is being used for permanent wiring in one or more areas. This wiring is not intended to be used as permanent wiring, and poses a safety hazard of shock and fire. A qualified electrician should evaluate and make repairs as necessary.
     
    Attic Return to table of contents  
    Inspection method: Traversed
    Roof structure type: Trusses
    Ceiling structure: Ceiling beams
    Insulation material: Fiberglass loose fill
    Insulation depth: 8 inches
    Insulation estimated R value: R-30
    5) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    6) Ceiling insulation is missing in some areas. Recommend installing insulation where missing for better energy efficiency.

    Photo 3  
     
    7) Some attic areas were inaccessible due to stored items, lack of permanently installed walkways, the possibility of damage to loose fill insulation, and/or low height. These areas are excluded from this inspection.
     
    Electric service Return to table of contents  
    Primary service type: Underground
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 150
    Service voltage (volts): 120/240
    Location of main service switch: Garage
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Copper
    System ground: Copper
    Main disconnect rating (amps): 150
    Branch circuit wiring type: Non-metallic sheathed
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: Yes
    8) One or more ground fault circuit interrupter (GFCI) breakers in the main service panel would not trip when tested. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs and/or replace circuit breakers as necessary.
     
    Water heater Return to table of contents  
    Estimated age: 8 yrs.
    Type: Tank
    Energy source: Electric
    Capacity (in gallons): 50
    Manufacturer: Bradford White
    Water temperature (degrees Fahrenheit): 115
    9) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    10) Water stains were found below the water heater. This may be a sign that the water heater is failing. A qualified plumbing contractor should evaluate and replace or repair the water heater if necessary.
    11) No water supply shut-off valve is visible for the water heater. A shut-off valve allows the supply to the water heater to be turned off when the water heater needs repair or replacement, while allowing the remainder of the plumbing system to be operable (toilets, sinks, etc.). Recommend having a qualified, licensed plumbing contractor determine if a water supply shut-off valve exists, and install one if it is missing.

    Photo 7  
     
     
    Heating and cooling Return to table of contents  
    Estimated age: 20 yrs.
    Primary heating system energy source: Natural gas
    Primary heat system type: Forced air, Up draft, Standard efficiency
    Primary A/C energy source: Electric
    Primary Air conditioning type: N/A
    Distribution system: Sheet metal ducts
    Manufacturer: Bryant
    Filter location: In return air duct above furnace
    Last service date: Unknown
    12) The estimated useful life for forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    13) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
     
    Plumbing and laundry Return to table of contents  
    Water pressure (psi): 65 psi
    Location of main water shut-off valve: Front yard
    Location of main water meter: Front yard
    Location of main fuel shut-off: Back yard
    Visible fuel storage systems: Gas
    Water service: Public
    Service pipe material: Not visible
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Not visible
    Fireplaces, woodstoves and chimneys Return to table of contents  
    Fireplace type: Masonry with metal liner
    Chimney type: Masonry
    Kitchen Return to table of contents  
    14) The dishwasher is excessively noisy. A qualified appliance technician should evaluate and repair as necessary, or the dishwasher should be replaced.
    15) The range hood fan is inoperable. A qualified contractor should evaluate and repair or replace the fan or the range hood as necessary.
    16) One or more stove top burners are inoperable. A qualified appliance technician should evaluate and repair as necessary.
     
    Bathrooms Return to table of contents  
    17) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    18) One or more exhaust fans is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary.

    Photo 6  
     
    19) One or more faucets leak or drip when turned off. A qualified plumber should evaluate and repair as necessary.

    Photo 4  
     
     
    Interior rooms Return to table of contents  
    20) Relatively few electric receptacles are installed in one or more interior rooms. This can result in "octopus" wiring with extension cords, which is a fire hazard. A qualified electrician should evaluate and install additional receptacles as necessary and as per standard building practices.
    21) An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    22) The doorbell appears to be inoperable. Recommend having a qualified electrician evaluate and repair as necessary.
    23) Seals between double-pane glass in one or more windows appear to have failed based on condensation or stains between the panes of glass. A qualified contractor should evaluate and replace glass where necessary.

    The client(s) should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too.

    Photo 5  
     
     
    Thank you for choosing CORE Home Inspections. "Committed to excellence"