Website: http://InspectingTheUnexpected.com
Email: Bill@InspectingtheUnexpected.com
Phone: (205) 567-7803
FAX: (205) 567-7803
629 Valley View Lane
Remlap, AL 35133
Inspector: William Corbett
|
Property Inspection Report |
| Client(s): |
Ashley Hammond |
| Property address: |
165 Village Trace Drive Springville, AL 35146 |
| Inspection date: |
Monday, February 08, 2010 |
This report published on 2/8/2010 6:44:16 PM CST
View summary page
This report is the exclusive property of Magic City Inspections and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
This report includes both a DETAIL SECTION and a SUMMARY SECTION. You may select to view and or print in either mode or both. Many areas of this inspection report will contain hyperlinks which will direct you to expert informative details on a subject of concern.
Please understand that all homes, regardless of their age, have some number of defects or issues to address or monitor. Home inspection reports by nature focus on defects and thus may seem negative in tone. Many or even most features of this property may be in excellent condition and of high quality and may have been deemed "adequate or acceptable" for purposes of this report. Therefore, many of the 545 plus items from the inspectors field notes list that were inspected/viewed or considered and were deemed adequate or acceptable, may not be specifically commented on in the written report. This is not meant to downplay this property's assets, but rather to focus attention on alerting you to the potentially important issues. These are those specific areas that need attention, evaluation, maintenance, or those items which may create safety concerns or possible major or costly repair and replacement expense.
This report will also contain items to alert or advise you of common things which a homeowner may want or need to know. These may include information on specific location of meters, shut-off switches, turn-off valves and other data which will help the owner better understand the items, systems or mechanics of the home.
This inspection complies with the National Association of Certified Home Inspectors' (NACHI) "Standards of Practice" and " Codes of Ethics"and in most cases meets or exceeds most other American and National standards of practice. These standards list items to be described in this report and items to be observed or evaluated during an inspection. Cosmetic items such as nicked or damaged molding, trim, interior paint or carpet issues are generally not a major concern of this report and may be excluded from this report.
Our report contains valuable information that is for your analysis now, as well as, specific maintenance details and reference information that will prove important to you for years to come.
Thank you for choosing, Magic City Inspections. You will benefit from the diligent approach taken in inspecting your property. This should assist you in getting the maximum return from your investment with the least amount of worry.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor defect | Correction only involves a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Monitor | Recommend monitoring in the future |
 | Comment | For your information |
Structural Pest Inspection Concerns
Concerns relating to the structural pest inspection are shown as follows:
 | Infestation | Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) |
 | Damage | Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) |
 | Conducive conditions | Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Report number: 10020801
Time started: 8:20
Time finished: 11:45
Present during inspection: Client
Client present for discussion at end of inspection: Yes
Weather conditions: Clear, Recent rain
Temperature: Cold
Ground condition: Damp
Inspection fee: 299.00
Payment method: Check
Type of building: Single family
Buildings inspected: 165 Village Trace Drive Springville, AL 35146
Age of building(s): 2008
Occupied: No
1)
Evidence of rodent infestation was found in the form of trails in insulation in one or more areas including the attic. Recommend consulting with the property owner about this. A qualified person should make repairs to seal openings in the structure, set traps, and clean rodent waste as necessary. Recommend following guidelines in these Center for Disease Control articles:
http://www.cdc.gov/rodents/prevent_rodents/seal_up.htm
http://www.cdc.gov/rodents/prevent_rodents/trap_up.htm
http://www.cdc.gov/rodents/prevent_rodents/clean_up.htm
2)
The natural gas service was turned off. As a result, some appliances such as water heater(s), forced air furnace(s), gas fireplace(s), stove(s), range(s) and/or gas supply lines weren't fully evaluated. The inspector was unable to test for gas leaks.

Photo 20
|
|
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Condition of retaining walls: Appeared serviceable
Retaining wall material: Block
Site profile: Moderate slope
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Condition of decks, porches and/or balconies: Appeared serviceable
Condition of guardrails: Appeared serviceable
Deck, porch and/or balcony material: Wood
Condition of exterior stairs: Appeared serviceable
Condition of handrails: Appeared serviceable
Exterior stair material: Wood
3)


Bench seating was permanently installed at some sections of guardrails with drop-offs higher than 30 inches. This is a safety hazard due to the risk of falling when someone (especially children) is standing on the seating. Recommend having a qualified person evaluate and repair as necessary to eliminate the fall hazard. For example, by removing or moving the seating, or extending the guardrail height.
4)

Flashing was missing from above one or more deck ledger boards. This can cause moisture to accumulate between the ledger board(s) and the building. Rot may result in this area and cause the ledger board fasteners to fail. The deck may separate from the building in this event and poses a significant safety hazard. A qualified contractor should install flashing above ledger board(s) where necessary. For more information on installing deck ledger boards visit:
http://www.hometime.com/Howto/projects/decks/deck_4.htm
And for more information on building safe decks in general, visit: http://www.thisoldhouse.com/toh/knowhow/exteriors/article/0,16417,212625,00.html

Photo 25
|
|
5)

One or more retaining walls higher than three feet were found on this property and guardrails or barriers were missing. This is a safety hazard due to the risk of falling. At a minimum, the client should be aware of this hazard, especially when children are present. Ideally a qualified contractor should install adequate guardrails or make modifications to existing barriers as necessary above retaining walls higher than 3 feet to eliminate fall hazards. Dense shrubbery or vegetation may be acceptable as a barrier, but only when mature enough to be effective.

Photo 33
|
|
6)
The perimeter grading sloped towards the building in one or more areas. This can result in water accumulating around the building foundation. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Photo 21
|
|
7)
Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.
8)
Minor cracks, settlement, heaving and/or deterioration were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Vinyl, Brick veneer
Condition of foundation and footings: Appeared serviceable
Foundation type: Unfinished basement
Foundation material: Poured in place concrete
Footing material: Poured in place concrete
Anchor bolts for seismic reinforcement: Installed
Anchor bolts for seismic reinforcement were observed at: Slab perimeter
Shear panels for seismic reinforcement: Not determined
Condition of floor substructure: Appeared serviceable
Pier or support post material: Steel
Beam material: Built up wood
Floor structure: Solid wood joists
Condition of the basement: Appeared serviceable
9)


Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains at support post bases, efflorescence on the foundation etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client should review any disclosure statements available and ask the property owner about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in basements include:
Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
Improving perimeter grading
Repairing, installing or improving underground footing and/or curtain drains
Ideally, water should not enter basements, but if water must be controlled after it enters the basement, then typical repairs include installing a sump pump.

Photo 36
|
|
10)

Some sections of siding and/or trim were loose, substandard. A qualified person should evaluate and repair, replace or install as necessary.

Photo 23
|

Photo 27
|

Photo 28
|
|
11)

Minor cracks or deterioration were found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.

Photo 14
|
|
12)

One or more exhaust duct end caps were damaged. Their purpose is to prevent unconditioned air from entering the building, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and may pose a fire hazard. A qualified person should evaluate and repair as necessary.

Photo 31
|
|
13)

One or more nuts on seismic reinforcement hardware such as sill plate anchor bolts or hold-downs were loose. A qualified person should evaluate and repair as necessary, and as per standard building practices.

Photo 38
|
|
14)
Gaps existed at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

Photo 29
|
|
15)
Caulk was missing around windows, around doors, at siding butt joints, at siding-trim junctions, at wall penetrations. A qualified person should repair or replace as necessary. For more information, visit:
http://www.reporthost.com/_docs/FPL_Caulking_Ins_Outs.pdf

Photo 13
|

Photo 15
|

Photo 22
|

Photo 40
|
16)
The exterior finish in some areas was failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.

Photo 35
|
|
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Roof type: Hipped
Age of roof surface(s): 2008+/-
Source for building age: Property listing
Roof inspection method: Viewed from ground with binoculars
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Condition of attic: Appeared serviceable
Attic inspection method: Partially traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Ceiling insulation material: Fiberglass loose fill
Ceiling insulation depth: 10"+/-
Ceiling insulation rating: R-30+/-
Vapor retarder: None visible
Roof ventilation: Appears serviceable
17)


Recessed "can" lights were installed in the ceiling below the attic. The inspector was unable to find a label or markings that indicated if these lights are designed to be in contact with insulation, and one or more lights are in contact with insulation. This is a possible fire hazard. Further evaluation should be performed, by a qualified contractor if necessary, to determine if these lights are rated for contact with insulation. If they aren't, or if their rating can't be determined, insulation should be moved, and wells or barriers should be installed or repaired as necessary to keep the insulation away from these lights.

Photo 53
|
|
18)

Roof repairs were needed because some composition shingles had the following conditions: nail pops, lifting. Leaks may occur as a result. A qualified contractor should evaluate and repair as necessary.

Photo 18
|

Photo 19
|
19)

Extensions such as splashblocks or drain pipes for many downspouts were missing, poorly sloped, substandard. Water may accumulate around the building foundation as a result. A qualified person should evaluate and repair, replace or install as necessary

Photo 12
|

Photo 16
|

Photo 24
|
|
20)
No insulation was installed at the attic access hatch. Recommend installing insulation at hatch for better energy efficiency. For more information, visit:
http://www.reporthost.com/_docs/atticaccess.pdf

Photo 55
|
|
21)

Stains were visible on the roof structure in one or more areas. These areas were dry at the time of the inspection. The stains may be caused by a past leak. Recommend asking the property owner about past leaks. The client should monitor these areas in the future, especially after heavy rains, to determine if active leaks exist. If leaks are found, a qualified contractor should evaluate and repair as necessary.

Photo 54
|
|
22)
Because of the roof configuration, weather, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
Type: Attached, Garage
Condition of garage: Appeared serviceable
Type of garage: Solid core, Metal
Condition of garage vehicle door(s): Appeared serviceable
Garage vehicle door type: Sectional
Number of vehicle doors: 2
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: Adequate
23)


The garage-dwelling door didn't latch when it closed. This door is intended to prevent vehicle fumes from entering living spaces and to slow the spread of fire from the garage to living spaces. A qualified person should evaluate and make repairs as necessary.

Photo 42
|
|
24)
One or more automatic vehicle door openers couldn't be fully evaluated because they were disconnected.
25)
Minor cracks, heaving and/or settlement were found in one or more sections of slab floors.
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Underground
Number of service conductors: 4
Service voltage (volts): 120
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Aluminum
Main disconnect rating (amps): 200
System ground: Ground rod(s) in soil
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Basement
Location of main disconnect: Breaker at top of main service panel
Branch circuit wiring type: Nonmetallic sheathed, Copper, Aluminum multi
Condition of branch circuit wiring: Serviceable
Solid strand aluminum branch circuit wiring present: None visible
Condition of smoke detectors: Appeared serviceable
Smoke detectors present: Yes
Carbon monoxide detectors present: Yes
Smoke detector power source: Hard wired
26)


One or more connections with aluminum wires in panel #A lacked anti-oxidant paste. Oxidation usually occurs without it, and may result in poor connections, overheating, and possibly fires. A qualified electrician should evaluate and apply anti-oxidant paste as necessary.
27)


Non-metallic sheathed wiring was routed in one or more areas so it is subject to damage, such as on wall or ceiling surfaces. The insulation can be damaged by objects coming in contact with it and/or it being repeatedly moved. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary. For example, rewire using conduit, or re-routing through wall cavities.

Photo 30
|
|
28)


Some wiring was loose, unsupported, or inadequately supported. Standard building practices require non-metallic sheathed wiring to be trimmed to length, attached to runners or to solid backing with fasteners at intervals of 4-1/2 ft. or less. Fasteners should be installed within 12 inches of all enclosures. A qualified, licensed electrician should evaluate and repair as necessary. For example, trim wire to length and/or install staples as needed.
29)


One or more sections of wiring that weren't terminated were found. This is a potential safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary. For example, cutting the wire to length and terminating the wire with wire nuts in a securely anchored, covered, properly sized junction box.

Photo 32
|
|
30)


Some receptacles were broken, damaged. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair or replace as necessary.

Photo 46
|

Photo 52
|
31)

Some cover plates on switch boxes were missing. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary.

Photo 44
|
|
32)

One or more wall-mounted exterior light fixtures had wiring that's subject to water intrusion due to caulk not being installed around the light fixture's back plate. Caulk should be applied around the perimeter of back plates where missing. A gap should be left at the bottom for condensation to drain out.

Photo 26
|

Photo 34
|
33)

One or more electric receptacles appeared to have no power. Recommend asking the property owner about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Photo 47
|
|
34)
Some light fixtures were inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner. Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Location of main water meter: Front lawn
Location of main water shut: Garage
Water service: Public
Service pipe material: Plastic
Condition of supply lines: Appeared serviceable
Supply pipe material: Polyethylene
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
35)

One or more outside faucets were missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the building. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.
Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079
36)

One or more sections of water supply pipes were loose or had substandard support. A qualified person should evaluate and repair as necessary, and as per standard building practices.

Photo 10
|
|
37)

Water supply lines were damaged in one or more areas. A qualified plumber should evaluate and repair as necessary.

Photo 37
|
|
38)

Recommend having the septic tank inspected. Recommend having the tank pumped if it was last pumped more than 3 years ago.
39)
No expansion tank was installed on this structure's water supply system. Expansion tanks are recommended when a property is on a public water supply system and the property's water system is "closed" via a pressure reducing valve (PRV), check valve, or backflow preventer. No room for expansion of water exists in this type of system. Thermal expansion occurs when water is heated during non-use periods. In a closed system with no provision for expansion, its effects may include:
Backflow into the water main
Damage to water heater connections, gas water heater flue tubes and pumps serving washers and dishwashers
Leaking faucets
"Weeping" of water through the water heater temperature-pressure relief (TPR) valve
Noisy water hammer in the pipes.
Expansion tanks can eliminate these problems by giving water a place to go when thermal expansion occurs. When a water heating cycle ends, or when any fixture is opened within the system, the impact of thermal expansion is reduced, and water drains out of the expansion tank back into the system. Recommend having a qualified plumber install an expansion tank as per standard building practices.

Photo 11
|
|
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition of water heater: Appeared serviceable
Type: Tank
Estimated age: 2008
Energy source: Electricity
Capacity (in gallons): 50
Manufacturer: Rheem
40)

This water heater was not fully evaluated because the following condition(s) existed: water service turned off. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the appliance is operable. Note that as per the standards of practice for NACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to operate shut-off valves, pilot lights or overcurrent protection devices, or any controls other than "normal controls".
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition of heating system: Appeared serviceable
Location of heating system: Attic
Heating type: Forced air, Heat pump
Fuel type: Electric
Manufacturer: Trane
Condition of burners: Appeared serviceable
Condition of distribution system: Appeared serviceable
Distribution system: Ducts and registers
Condition of controls: Appeared serviceable
Condition of air filters: Required repair, replacement and/or evaluation (see comments below)
Location of air filters: Behind return air grill
41)

The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
42)
One or more air filters were dirty. A qualified person should replace filter(s) as necessary. Filters should be checked monthly and maintained as necessary in the future.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
Condition of cooling system and/or heat pump: Required repair, replacement and/or evaluation (see comments below)
Type: Split system, Heat pump
Estimated age: 2008
Approximate tonnage: 4 ton
Manufacturer: Trane
Condition of distribution system: Appeared serviceable
Condition of controls: Appeared serviceable
Condition of air filters: Appeared serviceable
Location of air filters: Behind return air grill
43)

The pad for the heat pump was not level. This unit requires adequate support. The compressor may be damaged if this unit is tilted ten or more degrees. The pad should elevate the unit above the soil to prevent corrosion too. A qualified contractor should evaluate and repair as necessary.

Photo 17
|
|
44)
The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
Location #A: Living room
Fireplace type: Prefabricated
Fuel type: Natural gas
45)
The gas fireplace at location #A was not fully evaluated because of the following conditions: gas supply turned off. As per the Standards of Practice for both the National Association of Certified Home Inspectors (NACHI) and the American Society of Home Inspectors (ASHI) the inspector does not operate gas shut off valves or light pilot lights during inspections.
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Electric
Condition of built: Appeared serviceable
46)

The range can tip forward, and no anti-tip bracket appeared to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit http://www.hgtv.com/hgtv/remodeling/article/0,1797,HGTV_3659_2017492,00.html

Photo 50
|
|
47)

The dishwasher drain line was not configured with a "high loop" or "air gap". A high loop is created by routing the drain line up to the bottom surface of the counter top above, and securely fastening it to that surface. It is meant to prevent water from siphoning out of the dishwasher, and to prevent water from the sink drain or food disposal from entering the dishwasher. Some dishwashers have a built-in high loop where one is not required to be configured in the drain line. The client should try to determine if a high loop is required for this brand and model of dishwasher (review installation instructions, etc.). If one is required, or it cannot be determined if one is not required, then a qualified contractor should install a high loop as per standard building practices.
Also, no "air gap" was installed. Air gaps are another device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client should consult with a qualified contractor to determine if an air gap should be installed.

Photo 3
|
|
48)
Shelving or other components were missing from one or more cabinets. Missing shelving and/or components should be replaced, and by a qualified contractor if necessary.

Photo 49
|
|
49)
The dishwasher wasn't securely attached to the counter above. Fasteners were missing. A qualified person should repair as necessary.

Photo 2
|
|
50)
Some cabinet surfaces, drawers and/or doors showed moderate damage.

Photo 48
|
|
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Hall bath
Location #B: Master bath
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: No
240 volt receptacle for laundry equipment present: Yes
51)

Moderate deterioration or damage was found in the tiled shower enclosure, including cracked grout. A qualified contractor should evaluate and repair as necessary. Note that damage to the wall or other structures behind this tile may be found upon further evaluation, and additional repairs may be needed.

Photo 4
|
|
52)
The sink drain stopper mechanism at location #B was inoperable. A qualified person should repair or replace as necessary.
53)
Caulk was missing by the wall, fixtures at the bathtub at location #A, B. A qualified person should repair as necessary.

Photo 7
|

Photo 8
|
54)
Caulk was substandard around the shower fixtures, enclosure at location #B . A qualified person should repair as necessary.

Photo 5
|

Photo 6
|
55)
The equipment for the jetted tub at location #B was inaccessible (no access hatch, permanently installed hatch, etc.). The inspector was unable to evaluate the jetted tub equipment.

Photo 9
|
|
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Metal
Condition of exterior entry doors: Appeared serviceable
Condition of interior doors: Appeared serviceable
Type of windows: Vinyl, Multi, Single hung
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall
Condition of ceilings: Appeared serviceable
Flooring type or covering: Wood, Tile
56)

Handrails at one or more flights of stairs were missing. This is a safety hazard. Standard building practices require that handrails be:
Installed at stairs with three or more risers
Sized and shaped so your hand can encircle them
Permanently and securely attached, and able to withstand a 200 pound force in any direction at any point
Continuous and extend for the entire flight of the stairs
Located between 30 and 38 inches above the leading edge of the stair treads
A qualified person should repair, replace or install as necessary and as per standard building practices.

Photo 43
|
|
57)

The front door's doorbell appeared to be inoperable. A qualified person should evaluate and repair as necessary.
58)

Some windows that were built to open were difficult to open and close. A qualified person should evaluate and repair as necessary.

Photo 39
|
|
59)
Glass in some windows was cracked or broken. A qualified contractor should replace glass where necessary.

Photo 41
|
|
60)
Trim was damaged, deteriorated in some areas. A qualified person should repair as necessary.

Photo 45
|
|
61)
Wood flooring in some areas was significantly worn, deteriorated or damaged. A qualified contractor should refinish wood flooring as necessary.

Photo 51
|
|
62)
Minor cracks and/or holes were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
Thank you for allowing Magic City Inspection Services, LLC the opportunity to inspect and report on your home. We appreciate your business.
To prepare this report, a visual inspection was made of the visible and accessible areas of the structures on property.
This report is for your exclusive use in determining the physical condition of the property inspected. Although a thorough inspection of the property was made, we wish to CAUTION you that conditions may change and equipment may become defective. The report should not be construed as a guarantee or warranty of the premises or equipment, or of future uses thereof. The section (2) of our SERVICE AGREEMENT, entitled "Standards of Practice of the National Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm", provides additional details. PLEASE READ IT CAREFULLY!
THE INSPECTION, BY NECESSITY, DEALS WITH AN EXISTING STRUCTURE THAT MAY HAVE OLDER TYPES OF PLUMBING OR WIRING. ALTHOUGH THE SYSTEMS DID MEET REQUIREMENTS AT THE TIME THEY WERE INSTALLED, IT IS VERY PROBABLE THAT THEY WOULD NOT MEET PRESENT STANDARDS.
A good example of this situation is the current requirement for Ground Fault Interrupter (GFI) circuits in kitchens, bathrooms, garages, basements, and for outdoor outlets. To determine the Durability and Serviceability of the components of the home for this report, the current requirements were not applied in these types of circumstances.
“Too many” numbered items in the property report doesn’t necessarily mean that there are “too many” problems; it only means that there is site-specific information that needs to be conveyed to you to protect your interests—from safety, maintenance, and financial standpoints. Often, what looks like a serious defect can be corrected at minimal expense. On the other hand, sometimes a trivial-sounding item can be very expensive to repair, or not repairing it could result in significant property deterioration, injury, or death, usually because of additional problems related to the so-called trivial item. If you have any questions or concerns, though, please always feel free to contact me directly.