Complete Home Inspection LLC

Website: http://www.yourcompletehomeinspection.com
Company email: ron@yourcompletehomeinspection.com
Inspector's email: completehomeinspec@yahoo.com
Company phone: (574) 904-4459
Inspector's phone: (574) 904-1304
P.o. Box 1061 
New Carlisle, IN 46552
Inspector: Ron Colpitts
HI00800074

  

Property Inspection Report
Client(s): Jay Foldenauer
Property address: 612 Whisperind Blvd.
LaPorte, Indiana 46350
Inspection date: 4/8/2010
This report published on Monday, April 12, 2010 6:19:02 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Crawl space
Bathrooms
Interior rooms
 
General information Return to table of contents
Inspector: Ron Colpitts
Type of building: Single family
Age of building: 2 Years
Time started: 3:30 pm
Time finished: 5:00 pm
Inspection Fee: 200.00
Payment method: Check
Present during inspection: Client(s)
Occupied: No, but furnishings and stored items are present
Weather conditions: Rain
Temperature: Cold
Ground condition: Wet
Front of structure faces: South
Main entrance faces: South
Foundation type: Crawlspace
Inspector: Ron Colpitts
Type of building: Single family
Age of building: 2 Years
Time started: 3:30 pm
Time finished: 5:00 pm
Inspection Fee: 200.00
Payment method: Check
Present during inspection: Client(s)
Occupied: No, but furnishings and stored items are present
Weather conditions: Rain
Temperature: Cold
Ground condition: Wet
Front of structure faces: South
Main entrance faces: South
Foundation type: Crawlspace
1) Many wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items. Many areas couldn't be evaluated.

Photo 13  

Photo 15  
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stone veneer, Vinyl
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
2) Gaps exist at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

Photo 4  
 

3) One or more outside faucets aren't anchored securely to the structure's exterior. Fasteners should be installed or replaced as necessary so faucets are securely anchored to prevent stress on plumbing supply lines and possible leaks.The faucet was very loose when the inspector installed the water pressure gage on the west side towards the front of the house.
4) One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.The yard light did not come on when the inspector tried to override the photo cell.
5) The substructure of the deck is excluded from the inspection due to limited access because of the low height.

Photo 5  
 
 
Roof Return to table of contents
Roof inspection method: Viewed from eaves on ladder
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 2 Years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
 
Garage Return to table of contents

6) The vehicle door has an electric opener installed, and the manual lock mechanism on the door hasn't been disabled. Damage or injury may occur if the vehicle door opener is operated with the manual lock engaged. A qualified contractor should disable or remove the lock mechanism. For more information on garage door safety issues, visit: http://www.cpsc.gov/cpscpub/pubs/523.html or http://www.ohdstl.com/safety.html

Photo 12  
 

7) Much of the garage, including areas around the interior perimeter and in the center are excluded from this inspection due to lack of access from stored items.

Photo 6  

Photo 7  
 
Attic Return to table of contents
Inspection method: Not inspected
Inspection method: Traversed
Insulation material: Mineral wool loose fill
8) No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
9) The attic access hatch was inaccessible due to stored items, debris, or the hatch being permanently closed. The inspector was unable to evaluate the attic, and it's excluded from this inspection. Recommend moving items or modifying hatch(es) as necessary to allow periodic evaluation of attic spaces.Will inspect at a later date when items are moved.

Photo 8  
 

10)   Attc views

Photo 24  

Photo 25  

Photo 26  

Photo 27  
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: In the garage on the east wall
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Aluminum
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Smoke detectors present: Yes
11)   View of electrical panel.

Photo 11  
 
 
Water heater Return to table of contents
Estimated age: 2 Years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: Bradford White
Model: MI40T6FBN 40
12)   View of water heater in garage closet

Photo 10  
 
 
Heating and cooling Return to table of contents
Estimated age: 2 Years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Natural Gas
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts
Manufacturer: Goodman
Model: GCH90703BXAB
Filter location: In return air duct above furnace
13) Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.
14) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
15)   Some construction debris was found in the furnace recommend having the furnace cleaned and seviced by a qualified heating contractor

Photo 9  
 
 
Plumbing and laundry Return to table of contents
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Location of main water meter: crawl space on front wall
16) The inspector was not able to find the main water shut-off valve. The client(s) should consult with the property owner(s) to determine if a shut-off valve exists, find it themselves, or hire a qualified plumber if necessary to find it. If no shut-off valve is found for the structure, then recommend having a qualified plumber install one to more easily allow the water supply to be turned off in the event of an emergency, such as when a supply pipe bursts.
17) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
18) The inspector was unable to test the sump pump for one or more reasons (no source of water, appeared unsafe, no power, etc.). The sump pump was not fully evaluated.No access to crawl space
19)   Water pressure gage taken from faucet on the outside of the house on the west side.

Photo 3  
 

20)   view of water meter and main water shutoff

Photo 19  
 
 
Crawl space Return to table of contents
Inspection method: Not inspected
Inspection method: Traversed
Insulation material underneath floor above: None visible
Pier or support post material: Wood
Beam material: Laminated wood
Floor structure above: Engineered wood joists
Vapor barrier present: Yes
21) Evidence of prior water intrusion was found in one or more sections of the crawl space. For example, sediment stains on the vapor barrier or foundation, and/or efflorescence on the foundation. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.

    Photo 21  
     

    22) The vapor barrier is in poor condition. For example, installed in a substandard way, large areas of exposed soil, cuts or tears in the plastic, significant amounts of sediment on top, etc. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified contractor should replace the vapor barrier. Standard building practices require the following:

  • The soil below the vapor barrier should be smooth and free from sharp objects.
  • Seams should overlap a minimum of 12 inches.
  • The vapor barrier should lap up onto the foundation side walls.

    Better building practices require that:

  • Seams and protrusions should be sealed with a pressure sensitive tape.
  • The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.

    Photo 20  
     

    23)   Crawl space was not inspected as inspector could not find access most likely due to stored items recommend asking home owner to reveal crawl space access and inspectior will come out to inspect
    24)   Entry to crawl space is in the front bedroom

    Photo 17  
     

    25)   The main drain line from the kitchen sink has had a section cut out and drain water is running down the wall and on the ground. This was verified by having an individule run water from the sink. Recommend having a qualified plumber repair the damage.

    Photo 22  

    Photo 23  

    26)   Unsupported copper pipe leading to outside hose bib recommend having a qualified plumber install required supports

    Photo 18  
     
     
    Bathrooms Return to table of contents

    27)   Coultered marble top is loose in main bath
    28)   Hole in the wall from what appears to be a missing towl bar.

    Photo 14  
     
     
    Interior rooms Return to table of contents

    29) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

    Photo 16  
     

     
    The inspection and report will be preformed according to the Standards of the American Society of Home Inspectors (ASHI) the terms in this agreement shall have the same meaning given to them in the ASHI standards. A copy of the ASHI standards will be provided at the client’s request. Visit www.ashi.org for further information.