Monarch Beach, California
Inspector: Reza Limonadi AIA

 

Property Inspection Report

Client(s):  Mr. & Mrs. Home Buyer
Property address:  789 New Lane
Nice City, California
Inspection date:  Thursday, February 20, 2014

This report published on Tuesday, April 29, 2014 9:41:04 AM PDT

Thank you for using Coastal Inspections for your inspection needs. I appreciate your business.

The following written report is prepared for the sole, confidential and exclusive use of the client(s) named above. It is designed to highlight major and significant defects observed on the day of the inspection, not minor or cosmetic ones (although these will be noted when observed as a courtesy). The report is intended as a general guide to help you evaluate the home. Read your entire Home Inspection Report before purchasing the property, paying close attention to all items noted on the report and to any exclusions and limitations listed. Any items noted that require further evaluation, any items not accessible or able to be located during the inspection and any items listed under the Visual Obstructions and Exclusions section should be investigated or evaluated before you purchase the home. I recommend that any needed repairs be made by a licensed, qualified contractor.

Your Home Inspection Report represents my good-faith opinions on the subjects listed within on the day of the inspection - no guarantee or warranty is either expressed or implied. Hidden or concealed defects are not included in this report. This report is not an insurance policy. Please be sure to read the entire report thoroughly and call promptly with any questions or concerns. This report shall supersede any written or verbal communication and comments made prior to providing the written report.

Best Wishes,

Reza Limonadi AIA
Registered California Architect
Licensed General Contractor
Certified Building Inspector
Certified Mold and Asbestos Inspector
Coastal Inspections


Inspector Introduction

Reza Limonadi AIA is an InterNACHI Certified Inspector for existing and new residential & commercial buildings under ASHI or CREIA & ASTM standards, Registered State of California Architect with over 20 years of experience in the construction of commercial, industrial and residential buildings, Licensed General Building Contractor (CSLB) specializing in residential constructions and renovations, Certified Residential and Commercial Mold Inspector, Certified Asbestos Building Inspector (EPA-HUD), and Indoor Air Quality inspector.
I have over 30 years cumulative experience in general building design and construction, residential and commercial property inspections, and environmental assessments and remediation (mold, asbestos, lead, radon, and indoor air quality). In addition, I am an active member of American Institute of Architects (AIA), InterNACHI, and International Association of Certified Indoor Air Consultants.
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeFuture improvementsRecommended correction for future improvements
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeServiceableItem or component is in serviceable condition
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces and chimneys
Kitchen
Bathrooms
Interior rooms


General information
Return to table of contents

Inspector's name: Reza Limonadi AIA
Structures inspected: Single Family Detached
Inspection Fee: $
Payment method: Invoiced
Present during inspection: Client(s), Contractor(s), Realtor(s)
Occupied: Yes
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Foundation type: Slab on grade
The following items are excluded from this inspection: Security system, Irrigation system, Central vacuum system, Playground equipment, Low voltage outdoor lighting, Water filtration system, Water softener system, Built-in sound system, Intercom system, Fire suppression system
Note: This is a visual non invasive inspection that does not cover items that are not visible to the inspector at the time of inspection. This inspection is limited to the major components of the structure only. All components outside of the building envelope are excluded from this inspection unless noted otherwise. Please refer to the excluded items in this section of the report for an itemized list of items that are not covered in this inspection. Furthermore, this inspection is not meant to include cosmetic concerns, although they may be included in the report.
1) This structure is in an overall good condition with no deferred maintenance issues or concerns, and is in a good overall structural condition, with no signs of settlement or stress cracks visible, except as noted in this report.
Photo
Photo 1-1
 


Exterior
Return to table of contents

Foundation material: Poured in place concrete
Wall covering: Stucco
Driveway material: Poured in place concrete, Porous pavers
Sidewalk material: Poured in place concrete, Poured in place concrete aggregate
Exterior door material: Solid core wood
2) One or more flights of stairs with more than two risers have no handrail installed. This is a safety hazard. Install graspable handrails that a hand can completely encircle for support per standard building practices.
Photo
Photo 2-1
Photo
Photo 2-2

3) Cracks, deterioration and/or damage were found in areas of the stucco siding. Evaluate and make repairs as necessary.
Photo
Photo 3-1
Photo
Photo 3-2
Photo
Photo 3-3
Photo
Photo 3-4
Photo
Photo 3-5
Photo
Photo 3-6

4) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested. This is a safety hazard due to the risk of shock. Evaluate and repair as necessary.
Photo
Photo 4-1
 

5) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
Photo
Photo 5-1
Photo
Photo 5-2
Photo
Photo 5-3
Photo
Photo 5-4
Photo
Photo 5-5
Photo
Photo 5-6
Photo
Photo 5-7
Photo
Photo 5-8

6) Cracks were found in concrete driveway, patio or sidewalk sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
Photo
Photo 6-1
Photo
Photo 6-2
Photo
Photo 6-3
Photo
Photo 6-4
Photo
Photo 6-5
 

7) This sprinkler system, their timing devices, and other low voltage components are beyond the scope of this inspection. These systems are beyond the building envelope and mostly are installed after the original construction by homeowners and or their contractor. Furthermore, these systems are not a major component of the building system and are excluded from this inspection. Evaluate for proper operation as necessary.
Photo
Photo 7-1
Photo
Photo 7-2
Photo
Photo 7-3
Photo
Photo 7-4
Photo
Photo 7-5
 

8) Other comments and concerns.
Photo
Photo 8-1
Crack in one front yard exterior masonry wall
Photo
Photo 8-2
Exterior faucet, the sink and drainage have not been installed yet
Photo
Photo 8-3
The barbecue igniters did not function adequately when tested
Photo
Photo 8-4
Fridge was not on when inspected
Photo
Photo 8-5
Rusty metal railing parts
Photo
Photo 8-6
Photo
Photo 8-7
Photo
Photo 8-8
One side access gate is stuck and inoperable
Photo
Photo 8-9
Repair one exterior stair handrail picket
Photo
Photo 8-10
Repair one exterior stair handrail connection to the wall

9) This structure displays excellent conditions throughout its exterior portion with no differed maintenance items and no major concerns, except as noted in this report.
Photo
Photo 9-1
Photo
Photo 9-2


Roof
Return to table of contents

Roof inspection method: Viewed from ground, Viewed from windows
Roof type: Cross gable
Roof covering: Concrete tile
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
10) Because of the roof covering and the visibility of the roof from the ground, the inspector did not traverse the roof and wasn't able to fully evaluate the entire roof.
Photo
Photo 10-1
 

11) Roof seems to be in serviceable condition viewed from the ground, and /or the windows. Attic space showed dry conditions with no signs of previous water damage visible.
Photo
Photo 11-1
Photo
Photo 11-2
Photo
Photo 11-3
Photo
Photo 11-4
Photo
Photo 11-5
Photo
Photo 11-6
Photo
Photo 11-7
Photo
Photo 11-8
Photo
Photo 11-9
Photo
Photo 11-10


Garage
Return to table of contents


12) There are hairline cracks in garage's concrete slab. These cracks are not structural and are of a cosmetic nature. Recommend sealing all cracks to prevent entry of moisture and to prevent further damage.
Photo
Photo 12-1
Photo
Photo 12-2

13) Because of birds being stored in the garage, the garage vehicular door could not be operated for an evaluation and is exempt from this inspection. Evaluate as necessary for proper functionality.
Photo
Photo 13-1
Photo
Photo 13-2
Photo
Photo 13-3
 

14) Other comments and concerns.
Photo
Photo 14-1
Garage attic access hatch could not be accessed for an evaluation. This area is exempt from this inspection
Photo
Photo 14-2
Some windows could not be accessed for an evaluation
Photo
Photo 14-3
Fire suppression system did not get evaluated and is exempt from this inspection
Photo
Photo 14-4
The water softener did not get evaluated and is exempt from this inspection

15) The door separating the garage and the living spaces is in a good working condition. This is a fire rated partition that is meant to stop and slow the spread of fire from the garage to the living areas. This door has all the needed elements such as a self closing device, fully gasketed construction and a solid core material.
Photo
Photo 15-1
Photo
Photo 15-2

16) This garage is in a good overall condition with all components functioning correctly, except as noted in this report.
Photo
Photo 16-1
Photo
Photo 16-2
Photo
Photo 16-3
Photo
Photo 16-4


Attic
Return to table of contents

Inspection method: Viewed from hatch
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass roll or batt
17) Recessed "can" lights are installed in the ceiling below the attic. The inspector was unable to find a label or markings that indicated if these lights are designed to be in contact with insulation, and one or more lights are in contact with insulation. This is a possible fire hazard. Further evaluation should be performed to determine if these lights are rated for contact with insulation. If they aren't, or if their rating can't be determined, insulation should be moved, and wells or barriers should be installed or repaired as necessary to keep the insulation away from these lights.
Photo
Photo 17-1
Attic space in the casita
 

18) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
Photo
Photo 18-1
 

19) No insulation is installed over the attic access hatches. Recommend installing insulation above hatch for better energy efficiency.
Photo
Photo 19-1
Photo
Photo 19-2
Photo
Photo 19-3
 

20) Attic is in a good overall condition that displays adequate ventilation, proper insulation and adequate protection of all components routed through. It also displays a structural condition that is proper, secure and safe. There are no signs of excessive movement, lack of support or improper modifications to the structural components of this building.
Photo
Photo 20-1
Photo
Photo 20-2
Photo
Photo 20-3
Photo
Photo 20-4
Photo
Photo 20-5
Photo
Photo 20-6

21) The attic area was viewed from the access hatch. Areas beyond the inspectors visual range in the attic space are not covered in this report. Intent of this inspection is to get a sense of the house's structural make-up and stability. This inspection is not a complete attic inspection and in the case that a complete visual inspection is necessary, your inspector will inform you.
22) Ceiling insulation is missing in some areas. Recommend installing insulation where missing for better energy efficiency.
Photo
Photo 22-1
Photo
Photo 22-2
Photo
Photo 22-3
Photo
Photo 22-4
Photo
Photo 22-5
 


Electric service
Return to table of contents

Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 400
Service voltage (volts): 120/240
Location of main service panel: Side YardPantry
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Copper
Main disconnect rating (amps): 200
Solid strand aluminum branch circuit wiring present: No
23) Labels for the breakers in the sub-service panel is missing, unreadable or incomplete. Recommend installing, updating or correcting the labels as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.
Photo
Photo 23-1
Photo
Photo 23-2

24) The electrical service panel is in serviceable condition having all needed components, and is adequate for the size of the structure.
Photo
Photo 24-1
Photo
Photo 24-2
Photo
Photo 24-3
Photo
Photo 24-4
Photo
Photo 24-5
Photo
Photo 24-6
Photo
Photo 24-7
Photo
Photo 24-8
Photo
Photo 24-9
 


Water heater
Return to table of contents

Estimated age: 2004
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 30
Manufacturer: Bradford White
Note: Our inspection of major systems is limited to the normal operating functions of items listed. Independent evaluations including adequate sizing is not within the scope of this report. If such evaluation is required, we suggest contacting appropriate specialists.
25) There are non compatible metal connection used in this water heaters plumbing connections. Replace with similar metal connections to avoid corrosion and damage to the piping system.
Photo
Photo 25-1
Casita water heater
Photo
Photo 25-2
Casita water heater

26) Other comments and concerns.
Photo
Photo 26-1
The water circulation pump and timer did not get evaluated and are exempt from this inspection
 

27) Water heaters are in serviceable condition, providing adequate hot water and displaying all essential components such as appropriate seismic straps, and drain lines for their pressure relief valves.
Photo
Photo 27-1
Casita water heater
Photo
Photo 27-2
Casita water heater
Photo
Photo 27-3
Casita water heater
Photo
Photo 27-4
Casita water heater
Photo
Photo 27-5
Photo
Photo 27-6
Photo
Photo 27-7
 

28) A permanently installed insulated jacket is installed on the water heater. It obscures the manufacturer's information label and most of the water heater. The inspector was unable to fully evaluate the water heater.
Photo
Photo 28-1
 


Heating and cooling
Return to table of contents

Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: Carrier
Filter location: In return air duct below furnace
Note: Our inspection of major systems is limited to the normal operating functions of items listed. Independent evaluations including the adequacy/inadequacy of heating and cooling systems (such as adequate sizing of the units, cracked heat exchangers, air conditioning pressure tests, etc.) water flow (such as gallons per minute), electrical amperage/voltage adequacies are not within the scope of this report. If such detailed information is required, we suggest contacting appropriate specialists.
29) The outside condensing unit is not securely connected to a base or to the concrete decking beneath. Damage may occur if the unit shifts due to vibration. Evaluate and repair as necessary so the unit is secure to its base.
Photo
Photo 29-1
Casita condenser
 

30) Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.
Photo
Photo 30-1
Casita heat pump unit
Photo
Photo 30-2
Photo
Photo 30-3
Photo
Photo 30-4
Photo
Photo 30-5
 

31) Other comments and concerns.
Photo
Photo 31-1
Cut back all vegetation which are in direct contact with the Casita's condenser unit
 

32) Condenser units are equipped with adequate electrical shut off switches.
Photo
Photo 32-1
Casita condenser's shut off switch
Photo
Photo 32-2

33) Temperatures
Photo
Photo 33-1
Heater reached above 100 f in heating mode (upper level)
Photo
Photo 33-2
A/C reached below 50 f in cooling mode (upper level)
Photo
Photo 33-3
Heater reached above 100 f in heating mode (lower level)
Photo
Photo 33-4
A/C reached below 50 f in cooling mode (lower level)
Photo
Photo 33-5
Heater reached above 100 f in heating mode (casita)
Photo
Photo 33-6
A/C reached below 50 f in cooling mode (casita)
Photo
Photo 33-7
62 f ambient temperature
 

34) Furnaces are all in serviceable condition, providing adequate heat to the living areas when their controls were operated.
Photo
Photo 34-1
Photo
Photo 34-2
Photo
Photo 34-3
Casita ceiling mounted heat pump unit
 

35) Condensing units are in serviceable condition, providing needed thermal exchange to supply the living areas with cool air, when their controls were operated.
Photo
Photo 35-1
Photo
Photo 35-2
Photo
Photo 35-3
Casita condenser
 


Plumbing and laundry
Return to table of contents

Water Pressure: 45 psi
Location of the main water shut off valve: Side Yard, Garage
Location of main water meter: Sidewalk
Location of main fuel shut-off: Side Yard
Visible fuel storage systems: No
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
36) The washing machine is installed over finished flooring inside living space and has no catch pan or drain installed. These are not commonly installed, but they are recommended to prevent water damage to finished interior spaces below if or when the washing machine leaks, overflows or is drained. Recommend having a qualified contractor install both a catch pan and drain.
Photo
Photo 36-1
 

37) Adequate water pressure is supplied to this structure @ 45 Psi
Photo
Photo 37-1
 

38) This laundry area is in an overall good condition with no signs of deferred maintenance, and its components in a functioning state, except as noted in this report.
Photo
Photo 38-1
 

39) There is an adequate water pressure regulator installed on the main water line entering this structure.
Photo
Photo 39-1
Casita's unit
Photo
Photo 39-2

40) Neither the clothes washer nor the dryer were operated or evaluated. They are excluded from this inspection.
Photo
Photo 40-1
 

41) This Laundry room supports a gas only dryer. The client should be advised that an electric dryer unit will not work in this laundry room layout without an electrical modification.
Photo
Photo 41-1
 

42) Main water shut off valve to the residence.
Photo
Photo 42-1
Casita's shut off valve
Photo
Photo 42-2

43) Gas meter and gas valve for this property.
Photo
Photo 43-1
Photo
Photo 43-2


Fireplaces and chimneys
Return to table of contents

Fireplace type: Metal prefabricated
Chimney type: Framed over metal exhaust
Fuel Type: Gas and wood burning
44) Add a damper stop to prevent full closure of the fireplace damper. This will prevent build-up and allow ventilation of natural gases in case of any leaks in the gas supply system inside the fireplace.
Photo
Photo 44-1
Photo
Photo 44-2

45) Other comments and concerns.
Photo
Photo 45-1
One fireplace electric flame spreader did not get evaluated and is exempt from this inspection
 

46) Fireplace(s) in this structure are in serviceable condition with all parts functioning properly, except as noted in this report. There are no signs of deferred maintenance present.
Photo
Photo 46-1
Photo
Photo 46-2
Photo
Photo 46-3
Photo
Photo 46-4

47) There is no fire spreader pipe installed in one fireplace, but the unit has gas connection and control. Gas connection can not be evaluated without a spreader installed, and is exempt from this inspection.
Photo
Photo 47-1
 


Kitchen
Return to table of contents

Note: Inspection of kitchen components is limited to built-in gas or electric appliances and plumbing systems, if power is supplied. These items are tested under normal operating conditions. Extensive evaluations, such as calibration of timers, heat settings and temperature probes on cooking appliances are not within the scope of this report. Note: Due to the inaccessibility of the dishwasher components, we can do no more than operate under normal operating procedures. Dishwashers can fail at any time due to their complexity. Our review is to determine if the system is free of leaks and excessive corrosion. Shutoff valves and angle stops under kitchen or bathroom sinks and toilets are not turned or tested during the inspection due to the possibility of leaking. We suggest all shutoff valves or angle stops be turned regularly to ensure free movement in case of emergency.
48) Water leaked from the dishwasher's air gap device when it was operated. Debris may be clogging the drain line or the garbage disposal drain plug has not been punched yet (on new units). A qualified plumber or appliance repair technician should evaluate and repair as necessary.
Photo
Photo 48-1
 

49) The microwave oven appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, the microwave oven should be replaced, or a qualified appliance technician should evaluate and repair.
Photo
Photo 49-1
 

50) The kitchen sink drain has an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 50-1
Photo
Photo 50-2

51) Other comments and concerns.
Photo
Photo 51-1
Loose water filtration faucet
Photo
Photo 51-2
Ice / water dispenser did not get evaluated and is exempt from this inspection
Photo
Photo 51-3
Seal openings inside the kitchen sink cabinet giving access to concealed areas
 

52) This kitchen is in an overall good condition, with no signs of deferred maintenance issues or major concerns, except as noted in this report.
Photo
Photo 52-1
Photo
Photo 52-2


Bathrooms
Return to table of contents


53) There was no hot water connection in one bathroom faucet when inspected. Valves might be shut off preventing water flow to this faucet. Turning on water valves is not a part of this inspection since leaks might get started as a result. Turn on valves as needed for a full evaluation of the faucet.
Photo
Photo 53-1
Casita's bathroom faucet
 

54) One or more sink stopper mechanisms are missing, or need adjustment or repair. Stopper mechanisms should be installed where missing and/or repairs should be made so sink stoppers open and close easily.
Photo
Photo 54-1
Casita's sink
 

55) One or more bathtub drains are clogged or drain slowly. Drain(s) should be cleared as necessary.
Photo
Photo 55-1
Casita's bathtub
 

56) Other comments and concerns.
Photo
Photo 56-1
Minor mirror deterioration
Photo
Photo 56-2
Minor mirror deterioration
Photo
Photo 56-3
One bathroom's door frame has been broken around the lockset and this door can not latch as a result
Photo
Photo 56-4
Missing tile finish in one bathroom
Photo
Photo 56-5
Seal gaps and cracks
Photo
Photo 56-6
Fasten one loose shower control handle

57) Bathrooms in this buildings are all in a good overall condition displaying proper plumbing connections, adequate ventilation, and necessary electrical components such as GFCI outlets close to the sink. There are no signs of deferred maintenance, excessive moisture, or other related issues of concern, except as noted in this report.
Photo
Photo 57-1
Photo
Photo 57-2
Photo
Photo 57-3
Photo
Photo 57-4
Photo
Photo 57-5
Photo
Photo 57-6
Photo
Photo 57-7
Photo
Photo 57-8
Photo
Photo 57-9
 


Interior rooms
Return to table of contents


58) One or more smoke alarms are damaged, deteriorated and/or missing from their mounting brackets. Damaged and/or missing smoke alarms should be replaced as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html
Photo
Photo 58-1
Photo
Photo 58-2

59) A carbon monoxide detector is required on every floor of your home, including the basement. A detector should be located within 10 feet of each bedroom door and there should be one near or over any attached garage. Each detector should be replaced every five to six years.

Proper placement of a carbon monoxide (CO) detector is important. If you are installing only one carbon monoxide detector, the Consumer Product Safety Commission (CPSC) recommends it be located near the sleeping area, where it can wake you if you are asleep. Additional detectors on every level and in every bedroom of a home provides extra protection against carbon monoxide poisoning.

Homeowners should remember not to install carbon monoxide detectors directly above or beside fuel-burning appliances, as appliances may emit a small amount of carbon monoxide upon start-up. A detector should not be placed within fifteen feet of heating or cooking appliances or in or near very humid areas such as bathrooms.
60) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html
Photo
Photo 60-1
 

61) Lock mechanisms on one or more windows does not pull the window panel close enough for the lock to engage. Repairs should be made so that windows lock and unlock easily.
Photo
Photo 61-1
Photo
Photo 61-2

62) One or more doors will not latch when closed. Repairs should be made such as aligning strike plates with latch bolts and/or replacing locksets to have doors latch properly when closed.
Photo
Photo 62-1
One upper level bathroom
 

63) Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.
Photo
Photo 63-1
Photo
Photo 63-2
Photo
Photo 63-3
Photo
Photo 63-4
Photo
Photo 63-5
 

64) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.
Photo
Photo 64-1
Photo
Photo 64-2
Photo
Photo 64-3
Photo
Photo 64-4

65) There are cracked and or broken tiles in this structure that indicate presence of slab cracks under the tiled finish flooring. This is a sign of possible settlement or other factors resulting in structural movement. The cracks are minor in their appearance with no signs of major concerns.
Photo
Photo 65-1
Photo
Photo 65-2
Photo
Photo 65-3
Photo
Photo 65-4
Photo
Photo 65-5
Photo
Photo 65-6
Photo
Photo 65-7
 

66) Interior spaces in this building are in an overall good condition with no signs of deferred maintenance or other areas of concern, except as noted in this report. However, this house was occupied with furniture present during the inspection. Furniture and stored items does not allow a full visual access to all parts of the structure. Conditions, problems or flaws can be missed as a result.
Photo
Photo 66-1
Photo
Photo 66-2
Photo
Photo 66-3
Photo
Photo 66-4

67) Due to stored items and furniture around the house, the inspector could not access and test all the windows to evaluate functionality. Evaluate as needed to assure proper functionality.
Photo
Photo 67-1
Photo
Photo 67-2

68) There are water stains on the interior finishes of this structure indicating a past water intrusion and possible damage. All stains are dry currently, and the client should evaluate and repair as necessary.
Photo
Photo 68-1
Casita
Photo
Photo 68-2
Upper level
Photo
Photo 68-3
One upper level patio door allows water penetration from underside of its panels
 

69) Other comments and concerns.
Photo
Photo 69-1
Broken shades
Photo
Photo 69-2
One loose weatherstripping on an upper level patio door
Photo
Photo 69-3
Minor window screen tears
Photo
Photo 69-4
Photo
Photo 69-5
Photo
Photo 69-6
Bent screen frame
Photo
Photo 69-7
A section of the master bedroom's closet shelf and pole has collapsed
Photo
Photo 69-8
Photo
Photo 69-9
Some switches did not operate any fixtures
Photo
Photo 69-10
Tighten one loose door handle
Photo
Photo 69-11
Sound system and their components did not get evaluated and are exempt from this inspection
Photo
Photo 69-12
Refinish rusty parts on all metal railings
Photo
Photo 69-13
One lockset did not retract
Photo
Photo 69-14
One upper level patio door sill has been taped up to prevent water infiltration
Photo
Photo 69-15
Minor drywall cracks are not a structural concern
Photo
Photo 69-16

70) Upon occupancy, assure that there is a working smoke detector in every level, every bedroom, and all hallways leading to the bedrooms, located on the highest point on the ceiling. Furthermore, assure that there is a functional carbon monoxide detector on each level, located low on the wall for best detection. Replace all batteries in all detectors upon residency to assure proper protection and life safety.


This inspection meets or exceeds the Standards of Practice for the InterNational Association of Certified Home Inspectors (NACHI). It is intended as a general guide to help you make an evaluation as to the overall condition of the home. It is not intended to place a value on the home nor make any representation as to the advisability of purchase. It is not a guarantee or warranty. It is not an insurance policy.

The report reflects the opinion of the inspector(s), based upon visual impressions of conditions that existed at the time of inspection. The inspection is not intended to be technically exhaustive or to imply that every component in the home was inspected. No disassembly of equipment, opening of walls, moving of furniture or stored items was performed or is allowed by state requirements. All components which were concealed or obscured from observation at the time of inspection (including those concealed by clutter and stored items) are necessarily excluded from the report. Unless noted otherwise the house exterior was inspected from the ground. Only a representative sampling of parts and components (windows, electrical outlets, roof shingles, exterior wall trim and cladding, etc.) were examined and are within the scope of this inspection. Unless noted otherwise roofs and roofing materials are inspected from the ground with binoculars, from the roof edge when possible or from windows overlooking the roof.

Environmental hazards are not within the scope of the inspection and are excluded from the report. Any hazards noticed while performing the building inspection will be listed in the "Possible Environmental Hazards" section for your convenience so you can have them further investigated by an expert. These hazards include but are not limited to radon gas, carbon monoxide, lead and lead paint, buried storage tanks, asbestos, vermiculite, urea formaldehyde, and mold. Also excluded from the report are heating system heat exchangers, pools, hot tubs, spas, fountains, exterior lighting, water wells, zoning ordinances, intercoms, playground equipment, sports courts, elevators, outbuildings, septic tanks and sewage systems, water treatment equipment, security systems, sprinkler systems (both fire and lawn), bridges (over culverts, streams, ponds, etc.), generators, greenhouses, and central vacuum systems. Condo common areas are excluded. This is not an inspection for insects (including wood destroying), rodents birds, or other infestations. Reinspections or additional testing is not included and will incur an additional fee if needed. No warranty or guaranty of the home or components is implied by Coastal Home Inspections.

This inspection report is not a compliance inspection for any government codes or regulations, nor as a property or land survey. The types of water supply (public supply or private well) and waste disposal (public sewer or private septic system) cannot be accurately determined by a home inspection and were not part of your home examination. I recommend you check with your local City or other source of building records / permits to verify your type of system before purchase.