Thank you for using Coastal Home Inspections for your inspection needs. I appreciate your business.
The following written report is prepared for the sole, confidential and exclusive use of the client(s) named above. It is designed to highlight major and significant defects observed on the day of the inspection, not minor or cosmetic ones (although these will be noted when observed as a courtesy). The report is intended as a general guide to help you evaluate the home. Read your entire Home Inspection Report before purchasing the property, paying close attention to all items noted on the report and to any exclusions and limitations listed. Any items noted that require further evaluation, any items not accessible or able to be located during the inspection and any items listed under the Visual Obstructions and Exclusions section should be investigated or evaluated before you purchase the home. I recommend that any needed repairs be made by a licensed, qualified contractor.
Your Home Inspection Report represents my good-faith opinions on the subjects listed within on the day of the inspection - no guarantee or warranty is either expressed or implied. Hidden or concealed defects are not included in this report. This report is not an insurance policy. Please be sure to read the entire report thoroughly and call promptly with any questions or concerns. This report shall supersede any written or verbal communication and comments made prior to providing the written report.
Best Wishes,
Reza Limonadi AIA
Registered California Architect, Licensed General Contractor, Certified Building Inspector
Coastal Home Inspections
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor Defect | Correction likely involves only a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Serviceable | Item or component is in servicable condition |
 | Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Inspector's name: Reza Limonadi AIA
Structures inspected: Single Family Detached
Age of building: 33 Years
Inspection Fee: $300
Present during inspection: Property owner(s)
Occupied: Yes
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Foundation type: Slab on grade
1)

Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Evaluating for the presence of lead and/or asbestos is not included in this inspection.
2)
This structure has most of its major components in a good serviceable condition and mostly it passed the inspection.
Footing material: Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Wood panels, Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Wood panel, Glass panel
3)

One small hornet, bee and/or wasp nests was found. These can pose a safety hazard. Nest(s) should be removed as necessary.

Photo 18
|
4)
One or more downspouts are dented, damaged and/or crushed. This can restrict the water flow and result in clogging and overflowing gutters. Water may accumulate around the structure's foundation. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Damaged downspouts should be repaired or replaced as necessary, and by a qualified contractor if necessary.

Photo 9
Barried downspout.
|

Photo 24
Dented down spout.
|
5)
Seal pipe peneteration into the stucco finish, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

Photo 16
|

Photo 17
|

Photo 19
|
6)
Soil is in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.

Photo 4
|

Photo 6
|
7)
Refinish, seal and maintaine exterior wood finishes around the structure.
8)
There are some loose landscape bricks in the front yard planter that need to be reset.

Photo 8
|
9)
Side gate is showing some rusty spots, and should be refinished and sealed to prevent further damage.

Photo 10
|
10)
Master bedroom patio has a crack in its elastomeric flooring that needs to be resealed before causing damage.

Photo 33
|
11)
Wooden side fences are sitting directly on dirt and are covered with ivy on some sections. It is recommended that exterior wood be lifted away from dirt to protect against moisture and damage, and for ivy to be removed to prevent dryrot and insect infestation.

Photo 21
|

Photo 22
|

Photo 23
|
12)
Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
13)
Refinish stucco on the rear of the planter. A cosmetic condition.

Photo 20
|
Roof inspection method: Viewed from ground with binoculars
Roof type: Gable
Roof covering: Clay tile
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
14)

One or more roofing tiles are chipped and/or cracked. Tiles should be replaced as necessary.

Photo 35
|

Photo 36
|
15)
Roof is in a serviceable condition.
16)
Because of the roof covering type, the inspector was unable to traverse the roof without damage and wasn't able to fully evaluate the entire roof.
17)


One or more garage electric receptacles appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all garage receptacles, except for one for use with a refrigerator or freezer, have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

Photo 40
|

Photo 44
|
18)
Garage side entrance door is showing signs of deterioration and should be repaired or replaced by a qualified contractor.

Photo 13
|

Photo 14
|
19)
Seal opening in the exhaust duct in the garage.

Photo 43
|
20)
Much of the garage, including areas around the interior perimeter and in the center are excluded from this inspection due to lack of access from stored items.

Photo 45
|
Inspection method: Viewed from hatch
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass roll or batt
21)
No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
22)

Photo 39
|
Primary service type: Underground
Primary service overload protection type: Fuses
Service amperage (amps): 125
Service voltage (volts): 120/240
Location of main service switch: Side of structure
Main disconnect rating (amps): 125
Smoke detectors present: Yes
23)

Photo 11
|

Photo 12
|
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
24)
A water heater is installed over finished living spaces and has no catch pan and drain installed. Recommend having a qualified contractor install a catch pan and drain to prevent water damage to finished interior spaces below if/when the water heater develops a leak or is drained.

Photo 42
|
25)
Water heater is in a serviceable condition.

Photo 41
|
Estimated age: 4 to 5 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Natural Gas
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: Trane
Filter location: In return air duct above furnace
26)
Furnace and the condenser are both in a serviceable condition.

Photo 15
|

Photo 38
Attic Furnace.
|
Water pressure (psi): 50 Psi
Location of main water meter: By the side walk
Location of main fuel shut-off: Side of Structure
Water service: Public
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
27)

Copper water supply pipes in homes built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Evaluating for the presence of lead in this structure is not included in this inspection.
28)
This laundry is plumbed for gas and is wired for electrical dryer.
29)
Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
Fireplace type: Metal prefabricated
Chimney type: Masonry
30)
Both fireplaces are in a serviceable condition.

Photo 28
|

Photo 29
|
31)


One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

Photo 25
|

Photo 26
|

Photo 27
|
32)

The dishwasher drain line is not configured with a "high loop" or "air gap". A high loop is created by routing the drain line up to the bottom surface of the counter top above, and securely fastening it to that surface. It is meant to prevent water from siphoning out of the dishwasher, and to prevent water from the sink drain or food disposal from entering the dishwasher. Some dishwashers have a built-in high loop where one is not required to be configured in the drain line. The clients should try to determine if a high loop is required for this brand and model of dishwasher (review installation instructions, etc.). If one is required, or it cannot be determined if one is not required, then a qualified contractor should install a high loop as per standard building practices.
Also, no "air gap" is installed. Air gaps are another device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.
33)


One of the Master Bathroom's ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.

Photo 37
|
34)

Down stairs bathroom exhaust fans is very noisy . A qualified contractor should evaluate and replace the fan(s) or make repairs as necessary.
35)
Close all openings into the drywall system to prevent entry of insects into the wall cavities.

Photo 31
|
36)

An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
37)


Some ceiling areas in this structure have "popcorn" textured surfaces possibly installed prior to 1979. This material may contain asbestos, which is a known carcinogen and poses a health hazard.
In most cases, when the material is intact and in good condition, keeping it encapsulated with paint and not disturbing it may reduce or effectively eliminate the health hazard. If the client wishes to remove the material, or plans to disturb it through remodeling, they should have it tested by a qualified lab and/or consult with a qualified industrial hygienist or asbestos abatement specialist. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/453.html
38)
Some areas by the bar has been modified without modifying the flooring. A cosmetic condition.

Photo 30
|
This inspection meets or exceeds the Standards of Practice for the InterNational Association of Certified Home Inspectors (NACHI). It is intended as a general guide to help you make an evaluation as to the overall condition of the home. It is not intended to place a value on the home nor make any representation as to the advisability of purchase. It is not a guarantee or warranty. It is not an insurance policy.
The report reflects the opinion of the inspector(s), based upon visual impressions of conditions that existed at the time of inspection. The inspection is not intended to be technically exhaustive or to imply that every component in the home was inspected. No disassembly of equipment, opening of walls, moving of furniture or stored items was performed or is allowed by state requirements. All components which were concealed or obscured from observation at the time of inspection (including those concealed by clutter and stored items) are necessarily excluded from the report. Unless noted otherwise the house exterior was inspected from the ground. Only a representative sampling of parts and components (windows, electrical outlets, roof shingles, exterior wall trim and cladding, etc.) were examined and are within the scope of this inspection. Unless noted otherwise roofs and roofing materials are inspected from the ground with binoculars, from the roof edge when possible or from windows overlooking the roof.
Environmental hazards are not within the scope of the inspection and are excluded from the report. Any hazards noticed while performing the building inspection will be listed in the "Possible Environmental Hazards" section for your convenience so you can have them further investigated by an expert. These hazards include but are not limited to radon gas, carbon monoxide, lead and lead paint, buried storage tanks, asbestos, vermiculite, urea formaldehyde, and mold. Also excluded from the report are heating system heat exchangers, pools, hot tubs, spas, fountains, exterior lighting, water wells, zoning ordinances, intercoms, playground equipment, sports courts, elevators, outbuildings, septic tanks and sewage systems, water treatment equipment, security systems, sprinkler systems (both fire and lawn), bridges (over culverts, streams, ponds, etc.), generators, greenhouses, and central vacuum systems. Condo common areas are excluded. This is not an inspection for insects (including wood destroying), rodents birds, or other infestations. Reinspections or additional testing is not included and will incur an additional fee if needed. No warranty or guaranty of the home or components is implied by Coastal Home Inspections.
This inspection report is not a compliance inspection for any government codes or regulations, nor as a property or land survey. The types of water supply (public supply or private well) and waste disposal (public sewer or private septic system) cannot be accurately determined by a home inspection and were not part of your home examination. I recommend you check with your local City or other source of building records / permits to verify your type of system before purchase.