Property Inspection Report
Client(s): Sample01
Property address: FL 32322
Inspection date: 4/22/2011
This report published on Tuesday, May 31, 2011 3:13:10 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Electric service
Water heater
Heating and Cooling
Plumbing and laundry
Crawl space
Kitchen
Master Bathroom
Second Bathroom
Master Bedroom
Second Bedroom
Living Room
 
General information Return to table of contents
Report number: 042211-01
Inspector's name: Karen Kotowski, Mark Rocha
Structures inspected: Mobile home, shed
Type of building: Manufactured home
Age of building: 1970
Property owner's name: Sample, Joe
Time started: 9:30 a.m.
Time finished: 11:45 a.m.
Payment method: Invoiced
Occupied: No
Weather conditions: Clear
Temperature: Warm 70 degrees
Ground condition: Damp
Front of structure faces: South, West
Main entrance faces: South, West
Foundation type: Crawlspace
1) There are several trim and finish pieces missing throughout the home. These should be repaired by a qualified contractor. This is mostly a cosmetic issue.
2) There is a swale along the road and the lot slopes south to north and toward the buillding. Recommend monitoring to ensure crawl space does not flood during storms.
3) There are numerous dead branches overhead. Recommend trimming to prevent damage by falling..
4) There is a power pole that terminates in the side yard along street. Recommend removal for aesthetic and tripping hazard issues.
 
Exterior Return to table of contents
Footing material: None
Foundation material: Concrete block
Apparent wall structure: Wood frame
Wall covering: Vinyl
Driveway material: Dirt
Sidewalk material: None
Exterior door material: Metal with 1 glass light
5) One or more sets of stairs are wobbly. A qualified contractor should evaluate and repair as necessary, such as installing additional supports and/or diagonal bracing.
6) Newel cap at left side post on the deck stairs is loose. This is a safety hazard. A qualified contractor should make repairs as necessary.
7) Spacing where posts on deck meet the house exceed the 4 inches allowed by code. Recommend closing gap as small children can get caught.
8) There is a steel shed (approx 8x10) on slab. Shed appears to be at end of useful life. The bottom of the side panels is rusting. Recommend removal or replacement.
9) Siding shows signs of mildew. Recommend power washing.
10) Recommend cleaning deck(s) and treating with a preservative claiming to waterproof, block ultraviolet light, and stop mildew. Consumer Reports recommends these products:

  • Cabot Decking Stain and PTW Stain
  • Olympic Water Repellent Deck Stain
  • Thompson's House and Deck Stain
  • Wolman PTW Deck Stain
  • Akzo Sikkens Cetol DEK
  • Benjamin Moore Moorwood Clear Wood Finish
  • DAP Woodlife Premium
  • Olympic Natural Look Protector Plus
    11) The exterior paint finish on the front door is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices. Door aslo noted as inoperable in report section - living room.
    12) One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.
     
    Roof Return to table of contents
    Roof inspection method: Viewed from eaves on ladder
    Roof type: Gable
    Roof covering: Asphalt shingles
    Estimated age of roof: Unknown
    Gutter & downspout material: None
    Roof ventilation: Adequate
    13) Roof appears newer, however there is extensive evidence of water intrusion within the home. Recommend evaluation by a qualified roofer.
    14) Debris such as leaves, needles, seeds, etc. have accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 200
    Service voltage (volts): 120/240
    Location of main service switch: Outside on pole - Square D manufacturer, locked, not accessible
    Location of sub panels: Laundry Room - Thomas and Betts manufacturer
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Copper
    Main disconnect rating (amps): 200
    System ground: Ground rod(s) in soil
    Branch circuit wiring type: Copper
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: No
    15) One or more clamps that secure the electric service's grounding electrode conductor(s) to the grounding rod(s) appear to be missing. Grounding may be inadequate as a result and may be a safety hazard for shock. A qualified electrician should evaluate and repair as necessary.
    16) The service drop wires are in contact with trees or vegetation. Recommend having a qualified tree service company or arborist prune or remove trees as necessary to prevent straining or abrading the service drop wires.
    17) Recommend GFCI circuit be installed in second bathroom. None currently installed.
    18) Recommend AFCI breakers for sleeping areas. None are currently installed.
     
    Water heater Return to table of contents
    Estimated age: 1997
    Energy source: Electricity
    Capacity: 30 Gallon
    Manufacturer: State
    Model: SCI 30 1 HMS960 EQ
    19) Evidence of wood destroying organisms at hot water heater access panel. Recommend evaluation by a WDO firm.
    20) The water heater was functioning at the time of the inspection. The estimated life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
     
    Heating and Cooling Return to table of contents
    Estimated age: Mid 90's
    Primary heating system energy source: Electric
    Primary heat system type: Heat pump
    Primary A/C energy source: Electric
    Primary Air conditioning type: Heat pump
    Distribution system: Not visible. Covered within insulation
    Manufacturer: GMC compressor
    Model: CK36-18 compressor, heat pump unit unknown
    Filter location: In return air duct above furnace
    Last service date: Unknown
    21) The estimated useful life for most heat pumps is 15 to 20 years. This heat pump appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future. Rust is evident on the unit and unit was inoperable from thermostat.
    22) The outside condensing unit is not level. Damage may occur if it is more than ten degrees off from level. Weeds should be cleaned up around the unit and a qualified contractor should evaluate and make repairs as necessary, such as replacing the pad that the condensing unit is installed on.
    23) No filter is visible for the heating/cooling system. As a result, unfiltered air will flow through the system, and the heating/cooling equipment life and the indoor air quality may be reduced. Correctly sized filter(s) should be installed. If necessary, guides or retaining devices should be installed or repaired so filter(s) are securely anchored and gaps around edges are minimized.
    24) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
    25) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    26) Vegetation such as trees, shrubs and/or vines are too close to the outdoor condensing unit. Standard building practices require that there be at least 12 inches of clearance on all sides and at least four to six feet above. Inadequate clearances around the condensing unit can result in reduced efficiency, increased energy costs and/or damage to equipment. Vegetation should be pruned and/or removed as necessary to maintain these clearances.
    27) The heat and A/C were tested and are functioning. There is air flow to all rooms. Recommend adjustment to the fins in the vents to improve overall distribution and comfort if required after occupying.
     
    Plumbing and laundry Return to table of contents
    Water pressure (psi): Good
    Location of main water shut-off valve: Street
    Location of main water meter: Unknown
    Water service: Public
    Service pipe material: Not visible
    Supply pipe material: PVC
    Vent pipe material: Galvanized steel
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    28) Active leaks were found at the kitchen sink. Leaks are evident at the hot water stem at the handle, the cold water connection below the countertop and the drain at the right sink, below the sink. A qualified plumber should evaluate and repair as necessary.

    29) The toilet in the second bath requires the handle to be held continuously in order to flush. Recommend replacement as the porcelain on the unit is in poor condition overall. It will, however, function "as-is".
    30) The inspector was not able to find the water meter. Recommend that the client(s) attempt to find the water meter by consulting with the property owner(s), searching for it themselves, or consulting with the local water municipality. It is especially important to find the meter if no main shut-off valve is found because the meter may be the only way to turn off the water supply in the event of an emergency, such as when a supply pipe bursts.
    31) No washer or dryer is installed. They are excluded from this inspection. Dryer was observed to vent to outside below deck.
    32)   The drain at the shower in the master bath is sluggish. Recommend cleaning and/or evaluation by a plumber.
     
    Crawl space Return to table of contents
    Inspection method: Partially traversed
    Insulation material underneath floor above: Fiberglass roll or batt
    Pier or support post material: Concrete block
    Beam material: Steel
    Floor structure above: Solid wood joists
    Vapor barrier present: Yes
    Hurricane Tie-downs: Hurricane tie-downs were observed..
    33) The master bath toilet area has a missing floor section. The floor is cut away in this area. The toilet and plumbing should be evaluated for current leaks. Joists should be checked and the floor, insulation and vapor barrier repaired or replaced.
    34) Evidence of prior water intrusion was found in one or more sections of the crawl space. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:

  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.
    35) Insulation under the floor in the crawlspace is damaged, deteriorated, or has fallen down under the master bathroom. A qualified contractor should make repairs as necessary to restore the insulation to its original rating.
     
    Kitchen Return to table of contents

    36) Ground fault circuit interrupter (GFCI) electric receptacles to the left of the sink did not trip when tested. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    37) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    38) The range hood fan is inoperable. A qualified contractor should evaluate and repair or replace the fan or the range hood as necessary. Range hood was observed to vent to the outside.
    39) One or more stove top burners are inoperable. A qualified appliance technician should evaluate and repair as necessary.
    40) The dining area wall has been patched at the rear of the house. This should be monitored to verify that there are no wood destroying organisms or water intrusion during storms and repaired if required.
    41) Shelving or other components are missing from one or more cabinets. The drawer slides do not work and the middle drawer of the base cabinet to the left of the sink is missing. Missing shelving and/or components should be replaced, and by a qualified contractor if necessary.
    42) Pantry door is broken.
    43) One or more windows is missing a screen and/or window catch.
    44) One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary.
    45) Refrigerator shows signs of rust on outside and needs a good cleaning. It is an older unit that you may consider replacing in the near future.
    46) Sink stoppers are missing.
     
    Master Bathroom Return to table of contents

    47) The bathroom floor has a large hole in front of the toilet and rotted wood. Recommend repair by a qualified contractor. The plumbing should be evaluated after the water is turned on to verify the leak is repaired.
    48) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    49) One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary. Fixture glass globe is missing. Consider replacing fixture.
    50) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring.
    51) Window screen is missing.
    52) Door is missing between bedroom and bathroom.
    53) Sink shows evidence of a leaking stem on the cold water side. Should be evaluated and repaired by a qualified contractor if leak is evident after water is turned on.
     
    Second Bathroom Return to table of contents

    54) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    55) One or more toilet bowls, tanks and/or lids are cracked or broken. A qualified plumber should replace the toilet(s), tank(s) and/or lid(s) as necessary.
    56) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring. Also floor is crowned and slopes towards bedroom.
    57) Tub surround is cracked.
    58) Stains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary.
    59) Light fixture is missing globe.
    60) Sink is missing stopper.
     
    Master Bedroom Return to table of contents

    61) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    62) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    63) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    64) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor. Doors to closet and kitchen do not close.
    65) One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary. Globe is missing from light. Flourescent light bulb needs to be replaced in closet.
     
    Second Bedroom Return to table of contents

    66) Stains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary.
    67) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    68) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    69) One or more doors have no lockset installed. Locksets should be installed where missing.
    70) Carpeting is soiled and/or stained and damaged. Recommend replacing.
    71) There is a hole in the wall and evidence of repairs on the window wall. These should be monitored to make sure there is no water intrusion or wood destroying organism present and repaired if required.
    72)   No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html
     
    Living Room Return to table of contents

    73) The cover plate is missing from the electric box high on the wall at the door. Covers are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    74) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    75) One or more deadbolt mechanisms are inoperable or difficult to operate. A qualified contractor should evaluate and repair as necessary.
    76) Floor is crowned in the middle. This is somewhat common in mobile homes of this age, however, a qualified contractor should evaluate and make repairs as necessary.
    77) One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary. Glass globe is missing on fan.
    78) The front exterior entrance door is damaged and inoperopable and should be repaired or replaced by a qualified contractor.
    79) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring. This area has vinyl tiles installled.
    80) Trim is damaged and/or deteriorated in one or more areas. Recommend having a qualified contractor replace or repair trim as necessary.
     

    Photo 1  
    Slope of property from swale

    Photo 2  
    Broken pantry door

    Photo 3  
    Second Bedroom hole in wall and patch below windows

    Photo 4  
    Non-working and missing drawers

    Photo 5  
    Front view of home

    Photo 6  
    Electrical service pole

    Photo 7  
    Storage shed

    Photo 8  
    Wobbly back stairs

    Photo 9  
    Compressor with vegetation

    Photo 10  
    Front stairs wobbly

    Photo 11  
    Front door - non-working, paint peeling

    Photo 12  
    Unused power pole

    Photo 13  
    Space between post on deck and home exceeds 4"

    Photo 14  
    Grounding rod terminated with pipe clamp

    Photo 15  
    Electrical wiring passing thru tree

    Photo 16  
    Second Bath floor

    Photo 17  
    Second Bathroom broken toilet

    Photo 18  
    Second Bath cracked tub surround

    Photo 19  
    Master Bath hole in floor

    Photo 20  
    Master Bath vinyl tile floor

    Photo 21  
    Master Bedroom missing door

    Photo 22  
    Dining Area patched wall

    Photo 23  
    Second Bedroom broken door

    Photo 24  
    Second Bedroom

     