HOME ANALYSIS REPORT | |
| Client(s): | Sebastian Pleau |
| Property address: | 3068 Walker St Cardinal Ont |
| Inspection date: | 6/10/2010 |
This report is the exclusive property of Charles W. Boyd Home Inspection Services and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
| Safety | Poses a risk of injury or death | |
| Major Defect | Correction likely involves a significant expense | |
| Repair/Replace | Recommend repairing or replacing | |
| Repair/Maintain | Recommend repair and/or maintenance | |
| Maintain | Recommend ongoing maintenance | |
| Evaluate | Recommend evaluation by a specialist | |
| Monitor | Recommend monitoring in the future | |
| Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp| General Information | Return to table of contents |
![]() Photo 87 |
![]() Photo 88 Older floor tile in one bedroom noted, these could possibly contain asbestos. Care should be taken if removal is in the future.
|
![]() Photo 89 |
![]() Photo 60 |
![]() Photo 61 |
![]() Photo 69 |
![]() Photo 70 |
![]() Photo 120 Wood stove not hooked up during inspection, recommend removal from basement all together
|
![]() Photo 122 |
| Grounds | Return to table of contents |
![]() Photo 51 Trip hazard in front walkway
|
![]() Photo 52 Interlock in walkway has settled, could be removed and re-installed with proper packing of soil and sand base
|
![]() Photo 23 Some deck boards are beginning to rot on the ends,
|
![]() Photo 24 Deck is not in grat condition however it could be saved with some work, bracing and some paint would help it last a few more years
|
![]() Photo 18 Needs landscaping in most areas around house, negative slope will direct water toward foundation causing erosion, possibly water into basement.
|
![]() Photo 7 Vegetation is close to foundation, should be at least 1 foot away
|
![]() Photo 9 View across front, building sits square with no visible leaning or racking
|
![]() Photo 10 |
![]() Photo 20 |
![]() Photo 25 |
| Exterior / Foundation | Return to table of contents |
![]() Photo 8 Vinyl siding is in very good condition with only a couple of minor crack as shown.
|
![]() Photo 19 Basement windows are old, good condition for their age and very inefficient. Recommend budget for replacement windows in the future
|
| Roof / Attic | Return to table of contents |
![]() Photo 47 Standing water in gutters, slopes to corner with no downspout
|
![]() Photo 43 |
![]() Photo 44 Standing water in gutters, recommend a good cleaning and check to see if enough slope.
|
![]() Photo 48 |
![]() Photo 45 3 roof vents and 2 gable vents appear to be well ventilated, cannot verify if soffit vents are active as there is no attic access
|
![]() Photo 46 |
| Electric | Return to table of contents |
![]() Photo 4 Hot neutral reversed in outside recepticle, recommend replace with GFCI outlet and correct polarity
|
| Plumbing / Fuel Systems | Return to table of contents |
![]() Photo 117 No wate meter installed
|
![]() Photo 118 This would be your main water shut off
|
![]() Photo 119 Older galvanized or possibly lead service pipes from town water.
|
| Water Heater | Return to table of contents |
![]() Photo 114 |
| Heating | Return to table of contents |
![]() Photo 113 Furnace burners have yellowish flame, indicates cleaning and service needed
|
| Fireplaces / Stoves / Chimneys | Return to table of contents |
![]() Photo 35 |
![]() Photo 36 |
![]() Photo 37 |
![]() Photo 38 |
![]() Photo 39 Chimney is in poor condition, recommend repairs by qualified mason before next heating season
|
![]() Photo 40 |
| Kitchen | Return to table of contents |
![]() Photo 53 |
![]() Photo 54 |
![]() Photo 55 |
![]() Photo 56 Gas stove unplugged on arrival. Client chose to plug in and test and was satisfied that stove is working properly
|
![]() Photo 59 |
| Bathrooms / Laundry / Sinks | Return to table of contents |
| Interior Rooms / Areas | Return to table of contents |
![]() Photo 121 Water stains on basement ceiling tiles, no plumbing above this area, recommend evaluation when tiles are removed to see why stains are present.
|
![]() Photo 67 Large gap below front door.
|
![]() Photo 68 |
| Structural Pest Findings | Return to table of contents |
| Please read: | Return to table of contents |