Home inspection report by Certified Inspections
Client(s): Mr & Mrs Jones-Smith
Property address: 1234 Oak Anytown USA
Inspection date: Thurs, June 07, 2007
This report published on 6/11/2007 10:50:37 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major defectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Crawl space
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 001
Structures inspected: Home & Garage
Type of building: Single family
Age of building: !968
Time started: 1:00 pm
Time finished: 3:30
Payment method: check
Present during inspection: Client(s)
Occupied: No
Weather conditions: Clear
Temperature: Hot
Ground condition: Dry
Front of structure faces: South
Main entrance faces: South
Foundation type: Crawlspace
The following items are excluded from this inspection: Private sewage disposal system, Shed, Low voltage outdoor lighting, Water softener system Ventless fireplace


1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
2) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
     
    Exterior Return to table of contents
    Footing material: Poured in place concrete
    Foundation material: Concrete block
    Apparent wall structure: Wood frame
    Wall covering: Vinyl
    Driveway material: Asphalt
    Sidewalk material: Paving stones, Gravel
    Exterior door material: Solid core steel
    3) One or more large trees on the property may be likely to fall on the structure, and are a potential safety hazard. Recommend consulting with a qualified arborist to determine if tree(s) need to be removed and/or pruned.
    4) One or more outdoor electric receptacles appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all outdoor receptacles have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 11  
    GFCI outlet needed,Cpvc piping used for conduit,weather tight connector needed where conduit enters box

    Photo 27  
    Cpvc used,GFCI needed ,box not weather tight,temp.lighting should be removed or hard wired.

    5) Non-metallic sheathed wiring is routed in one or more areas so it is subject to damage, such as on wall or ceiling surfaces. The insulation can be damaged by objects coming in contact with it and/or it being repeatedly moved. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary. For example, rewire using conduit, or re-routing through wall cavities.

    Photo 20  
    Taped wire connection

    Photo 21  
    Wire and box not rated to be exposed to elements

    6) Flexible lamp or appliance cord is being used for permanent wiring in one or more areas. This wiring is not intended to be used as permanent wiring, and poses a safety hazard of shock and fire. A qualified electrician should evaluate and make repairs as necessary.

    Photo 27  
    Cpvc used,GFCI needed ,box not weather tight,temp.lighting should be removed or hard wired.
     

    7) Propane tank(s) are less than 10 feet from the structure. This is a safety hazard. The client(s) should consult with the property owner(s) and/or propane supplier, and have tank(s) moved as necessary, at least 10 feet from the structure.

    Photo 22  
    Tank to close to home
     

    8) One or more exterior electric receptacles aren't waterproof or rated for use in wet areas. This is a safety hazard due to the risk of shock and fire. Repairs should be made as necessary, and by a qualified electrician if necessary, so all exterior receptacles are waterproof as per standard building practices.

    Photo 27  
    Cpvc used,GFCI needed ,box not weather tight,temp.lighting should be removed or hard wired.
     

    9) One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

    Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079

    Photo 16  
    Plumbing exposed: freezing possible
     

    10) One or more hornet, bee and/or wasp nests were found. These can pose a safety hazard. Nest(s) should be removed as necessary. ON DECK
    11) Water supply pipes are routed outside and are subject to freezing. If unable to determine if shut-off valve(s) exist, or if none do, then a qualified plumber should evaluate and install interior shut-off valves as necessary to prevent pipes from freezing and bursting.

    Photo 16  
    Plumbing exposed: freezing possible
     

    12) Wood is split and starting to deteriorate on deck roof structure

    Photo 12  
    wood is deterorating needs mointured
     

    13) Gray water pipe appears to terminate in woods behind home: Gray water is that from a washing machine and or sink. Grey water pipes are not allowed in this county. Client should ask home owner if this is a grey water pipe and if it is should have grey water source terminate into septic tank by a qualified tech.

    Photo 17  
    Gray water pipe????
     

    14) The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope 1 Inch fall off per Foot for 6 feet
    15) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least 10 feet away from the structure to soil that slopes down and away from the structure.

    Photo 8  
    Extension needs to be installed,should terminate at least 10ft
     

    16) One or more gutters are missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install gutters and downspouts where missing. Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.

    Photo 18  
    Missing gutter at garage
     

    17) Roofing on deck was installed improper,needs to run vertical,water can not run off run properly
    18) One or more moderate cracks (1/8 inch to 3/4 inch) were found in the foundation. These may be a structural concern, or an indication that settlement is ongoing. The client(s) should consider hiring qualified contractors and/or engineers as necessary for further evaluation. Such contractors may include:

  • Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
  • Masonry contractors who repair and/or replace brick veneer
  • Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
  • Structural engineers who determine if repairs are necessary, and prescribe those repairs

    At a minimum, recommend sealing cracks to prevent water infiltration. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
    19) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
    20) Recommend cleaning deck(s) and treating with a preservative claiming to waterproof, block ultraviolet light, and stop mildew. Consumer Reports recommends these products:

  • Cabot Decking Stain and PTW Stain
  • Olympic Water Repellent Deck Stain
  • Thompson's House and Deck Stain
  • Wolman PTW Deck Stain
  • Akzo Sikkens Cetol DEK
  • Benjamin Moore Moorwood Clear Wood Finish
  • DAP Woodlife Premium
  • Olympic Natural Look Protector Plus

    Photo 13  
    Decking lacks any type of wood treatment
     

    21) One or more sections of foundation and/or exterior walls are excluded from this inspection due to lack of access from vegetation, debris and/or stored items.
    22)   wood exposed to elements under sliding door and above crawlspace vent,will rot and deteriorate. Wood under door needs flashing installed,wood used for shim above vent needs removed and mortar or other approved material be installed

    Photo 9  
    Shim added above vent:

    Photo 10  
    Wood exposed to elements
     
    Roof Return to table of contents
    Roof inspection method: Traversed
    Roof type: Gable
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 10 yrs
    Gutter & downspout material: Aluminum
    Roof ventilation: Adequate
    23) Sagging in roof where older roof meets newer roof. Newer roof is of poor construction, A qualified roofing contractor needs to evaluate this part of roof.

    Photo 4  
    Dip in roof where newer additon was added

    Photo 28  
    2X4 rafters & plywood supports

    24) Caulking and tar around roof vents. This could be trouble spots in the future.Needs to be monitor and maintain

    Photo 6  
    Chaulking type material around vent
     

    25) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.
    26) Some shingles have been replaced,attic could not be enter under this part of roof to check for active leaks.No active leak evidence in interior of home.

    Photo 3  
    Replaced shingles
     

    27)   Nails driven thru top of shingles in couple places, Qualified roof contractor needs to evaluate

    Photo 7  
    Nail in shingle
     
     
    Garage Return to table of contents

    28) Sub panel has oversized breakers and double tapped at breakers this is a safety hazard that could lead to injury and/or death,A qualified electrician needs to be called.Client called electrician while inspector was on premises and schedule a appointment.

    Photo 19  
    Wrong breaker size. Double tap wires
     

    29) Non-metallic sheathed wiring is routed in one or more areas so it is subject to damage, such as on wall or ceiling surfaces. The insulation can be damaged by objects coming in contact with it and/or it being repeatedly moved. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary. For example, rewire using conduit, or re-routing through wall cavities. Detached garage has unfinished walls this concern can be fixed with finished walls installed.
    30) Temp. wiring leading to flower garden near garage is being plugged in inside garage, GFCI is not installed,improper wire used and non-weathertight box being used.Safety:this concern can lead to injury or death,qualified electrician needs to evaluate.

    Photo 20  
    Taped wire connection

    Photo 21  
    Wire and box not rated to be exposed to elements

    31) Garage lacks gutters: water can cause damage to footer and slab,gutters should be installed and terminate at least 10 ft from garage and home.

    Photo 18  
    Missing gutter at garage
     
     
    Attic Return to table of contents
    Inspection method: Partially traversedOlder part of home was not accessible
    Roof structure type: Trusses, Rafters
    Ceiling structure: Trusses, Ceiling beams
    Insulation material: Cellulose loose fill
    Insulation depth: 6"
    32) Wire splices are exposed due to not being contained in a covered junction box. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes with cover plates where needed to contain wiring splices.
    33) Rafters were constructed of 2X4's at newer addition of home,Roof was sagging
    A qualified roof contractor should evaluate.

    Photo 4  
    Dip in roof where newer additon was added

    Photo 28  
    2X4 rafters & plywood supports

    34) The ceiling insulation's R rating is significantly less than what's recommended for this area. Recommend having a qualified contractor install additional insulation as per standard building practices for better energy efficiency.
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 100
    Service voltage (volts): 120/240
    Location of sub panels: In closet off kitchen,Garage,Back room behind familyroom.
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Copper
    System ground: Ground rod(s) in soil
    Main disconnect rating (amps): 100
    Branch circuit wiring type: Non-metallic sheathed
    Smoke detectors present: Yes
    35) The electrical systems has many safety issues, A qualified electrician should evaluate and repair.
    36) The service drop wires are less than three feet above one or more sections of roof with a slope of 3/12 (three inches vertical for every 12 inches horizontal) or more. This is a safety hazard for shock since people on the roof may come into contact with the service drop wires. The utility company and/or a qualified electrician should evaluate and repair as necessary.

    Photo 5  
    Service line less then 3ft of roof
     

    37) One or more wires in the main service panel appear to be undersized for their overcurrent protection devices (circuit breakers or fuses). This is a safety hazard due to the risk of fire. A qualified electrician should evaluate and repair as necessary.

    Photo 19  
    Wrong breaker size. Double tap wires
     

    38) One or more overcurrent protection devices (circuit breakers or fuses) are "double tapped", where 2 or more wires are clamped in a terminal designed for only one wire. This is a safety hazard since the bolt or screw may tighten securely against one wire, but leave others loose. Arcing, sparks and fires may result. A qualified electrician should evaluate and repair as necessary.

    Photo 19  
    Wrong breaker size. Double tap wires
     

    39) Neutral and equipment ground conductors are combined at one or more sub-panels. This should only occur in the main service panel, and is a safety hazard due to the risk of shock. Neutral conductors should be attached to a "floating" neutral bar not bonded to the panel, while grounding conductors should be attached to a separate grounding bar bonded to the sub panel. A qualified electrician should evaluate and repair as necessary.
    40) Kitchen ,Bathrm & outside outlets lack GFCI's. This inspector recommends GFCI's at all wet areas due to possible shock hazards.
    41) Temp.lighting is being used for over sink lighting,Perminate lighting should be installed. A qualified electrician should evaluate and repair.

    Photo 23  
    Gfci needed: above sink light needs perminate wiring
     

    42) CPVC piping being used for conduit(not rated for this use).Conduit must be secured not just laid on ground,Have qualified electrician evaluate and repair.

    Photo 14  
    Cpvc used for conduit and must be secured
     

    43) The main service panel cover is missing or not installed. Exposed, energized wiring and equipment exists as a result and is a safety hazard due to the risk of shock. The panel cover should be reinstalled or replaced, and by a qualified electrician if necessary. SUB-PANEL NEXT TO MAIN PANEL
    44) Extension cord being used for refridge.Fire hazard,remove cord and plug into outlet.

    Photo 24  
    Extension cord used for refridg.
     
     
    Water heater Return to table of contents
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 40
    Manufacturer: A.O. Smith
    Model: 125698766
    45) CPVC piping is being used for conduit,CPVC is not rated for this use, A qualified
    electrcian should evaluate and repair.

    Photo 25  
    Cpvc used for conduit
     

    46) The estimated useful life for most water heaters is 8 to 12 years. The inspector was unable to determine the age of the water heater due to the manufacturer's label being obscured, no serial number being visible, or the serial number not clearly indicating the age. The clients should be aware that this water heater may be near, at, or beyond its useful life and may need replacing at any time. Recommend attempting to determine the water heater's age, and budgeting for a replacement if necessary.
     
    Heating and cooling Return to table of contents
    Estimated age: 19 yrs (tag on A/C)
    Primary heating system energy source: Electric
    Primary heat system type: Forced air
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Sheet metal ducts
    Model: Kenmore
    Filter location: In return air duct below furnace
    Last service date: Tech. was servicing as home was being inspected
    47) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceeded this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

    Photo 15  
    A/C date 6/1988
     

    48) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    49) Service tech was called in by client and was present while home was being inspected.
     
    Plumbing and laundry Return to table of contents
    Water pressure (psi): 48 psi
    Location of main water meter: In front yard
    Water service: Public
    Supply pipe material: Copper
    Vent pipe material: Not visible
    Drain pipe material: Plastic
    50) Recommend having the septic tank inspected. Recommend having the tank pumped if it was last pumped more than 3 years ago.
    51) The inspector was not able to find the main water shut-off valve. The client(s) should consult with the property owner(s) to determine if a shut-off valve exists, find it themselves, or hire a qualified plumber if necessary to find it. If no shut-off valve is found for the structure, then recommend having a qualified plumber install one to more easily allow the water supply to be turned off in the event of an emergency, such as when a supply pipe bursts.
    52) Due to lack of accessibility of the crawlspace much of the plumbing was not inspected.
    53) Shut off valves were not installed at sinks supply lines!!
     
    Crawl space Return to table of contents
    Inspection method: Partially traversed
    Insulation material underneath floor above: None visible
    Pier or support post material:
    Beam material: Built up wood
    Floor structure above: Solid wood joists
    Vapor barrier present: No
    54) No insulation is installed under the floor in the crawl space. Recommend that a qualified contractor install R19 or better (6" thick fiberglass batt) insulation under the floor for better energy efficiency.
    55) No vapor barrier is installed. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified contractor should install a vapor barrier. Standard building practices require the following:

  • The soil below the vapor barrier should be smooth and free from sharp objects.
  • Seams should overlap a minimum of 12 inches.
  • The vapor barrier should lap up onto the foundation side walls.

    Better building practices require that:

  • Seams and protrusions should be sealed with a pressure sensitive tape.
  • The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.
    56) Band board has Some Wood destroying insect damage,appears to be old. Termite treatment papers were found in home by client.Inspector advised client to contact company to get information on past treatment. Some repairs where done to shore up floor support.

    Photo 26  
    Old wood destroying insect(WDI) damage and repair
     

    57) Some crawl space areas were inaccessible due to low height (less than 18 inches), ductwork or pipes blocking, standing water, and/or stored items. These areas are excluded from this inspection.
     
    Kitchen Return to table of contents

    58) One or more electric receptacles and/or the boxes they are installed in are loose and/or not securely anchored. Wire conductors may be damaged due to repeated movement and/or tension on wires, or insulation may be damaged. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary.
    59) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 23  
    Gfci needed: above sink light needs perminate wiring
     

    60) One or more cabinets are not securely fastened to the wall. This is a safety hazard due to the risk of the cabinet(s) falling. A qualified contractor should evaluate and repair as necessary.
    61) Drawers between sink and stove come in contact with each other not allowing one drawer not to open.
    62) Drawers are difficult to open and close in one or more cabinets. A qualified contractor should evaluate and repair as necessary.
    63) No range hood is installed over the range or cook top. Ventilation and/or lighting may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor install a vented and lighted range hood, with the exhaust fan configured so as to vent outdoors.
     
    Bathrooms Return to table of contents

    64) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    65) Door stop needed:Mirror is behind door and can be damage by door.
    66)   Tub faucet is loose,A qualified plumber should evaluate and repair.
     
    Interior rooms Return to table of contents

    67) One or more ceiling fans are installed less than seven feet from the floor below. This is a safety hazard. A qualified contractor should evaluate and repair as necessary. For example, remove fans, or move them as necessary to maintain a seven foot clearance below. Ideally ceiling fans should be installed at least eight to nine feet above the floor for optimal air flow.
    68) An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    69) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    70)   Ventless fireplace appears to be heat source for newer addition of home, Fireplace was not inspected.
     