Brown Home Inspections


321 Serene Hills, Hattiesburg, MS 39402
Inspector: Jason Brown

Property Inspection Report
Client(s): Chester Moore
Property address: 19 Chandelier
Hattiesburg, MS
Inspection date: 10/21/2011
This report published on Friday, October 21, 2011 4:56:08 PM CDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage / Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
 
General Information Return to table of contents
Time started: 10:00 AM
Time finished: 12:30 PM
Inspector: Jason Brown
Present during inspection: Client, Property owner
Client present for discussion at end of inspection: Yes
Weather conditions: Partly cloudy
Temperature: Cool
Ground condition: Dry
Inspection fee: 300
Payment method: Check
Buildings inspected: Single Family Home and Boat House
Age of building(s): 15+ years
Source for building age: Inspector's estimate
Front of building faces: East
Occupied: Yes
1) Many wall and floor surfaces were obscured by furniture, stored items and couldn't be fully evaluated.
 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Site profile: Minor slope
Driveway material: Asphalt
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Tile
Condition of decks, porches and/or balconies: Appeared serviceable
Condition of exterior stairs: Appeared serviceable
2) The perimeter grading sloped towards the building in one or more areas. This can result in water accumulating around the building foundation. The client should monitor this area at the north side of the house and may consider additional drainage methods.

Photo 6  
 

3) Sidewalks and/or patios had deterioration in one or more areas. A qualified contractor should evaluate and repair or replace sections as necessary.

Photo 39  

Photo 46  

4) One or more deck, patio and/or porch covers were damaged, deteriorated. A qualified person should evaluate and repair or replace as necessary, and as per standard building practices. Location Boathouse.

Photo 29  
 

5) One or more decks, porches and/or balconies were deteriorated, with loose fasteners or decking boards. A qualified person should evaluate and repair or replace as necessary. Boathouse

Photo 19  
 

6) Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from building exteriors. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and building exteriors.

Photo 1  

Photo 37  

7) Soil and water was in contact with or close to wooden deck substructure components of the boathouse. This is a conducive condition for wood destroying organisms. Standard building practices require the following clearances to soil below:

  • 12 inches below beams
  • 18 inches below joists
  • 6 inches below support post bases

    Soil should be graded and/or removed to maintain these clearances if possible. Otherwise, installing products such as borate based Impel rods may help to prevent infestation and damage. For more information, visit:
    http://www.google.com/search?q=impel+rods

    Photo 20  
     

    8) Wooden deck, porch and/or balcony surfaces, railings, built in seating should be cleaned and sealed by a qualified person. Some wood replacement will be necessary.

    Photo 28  
     

    9) Trees were in contact with or were close to the building in one or more areas. Damage may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
    10) Minor cracks, settlement, heaving and/or deterioration were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

    Photo 40  
     

    11) Most areas of the deck boat house substructure were inaccessible due to lack of access from Water. These areas couldn't be evaluated and are excluded from the inspection.
     
    Exterior / Foundation Return to table of contents
    Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
    Condition of wall covering: Appeared serviceable
    Apparent wall structure: Wood frame
    Wall covering: Stucco, Brick veneer
    Condition of concrete slab floor(s): Appeared serviceable
    12) Some sections of siding and/or trim were damaged. A qualified person should evaluate and repair, replace or install siding or trim as necessary.

    Photo 17  
     

    13) Rot or water damage was found at one or more sections of window sills, window frames, soffits, fascia. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced.

    Photo 11  

    Photo 34  

    Photo 38  

    Photo 42  

    Photo 43  

    Photo 44  

    Photo 45  

    Photo 68  

    14) Unlined planters should be removed. These can be a conduit for insects or moisture damage.

    Photo 10  
     

    15) Gaps existed at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

    Photo 8  

    Photo 14  

    16) Stucco siding should be evaluated and repaired as needed.

    Photo 41  
     

    17) Additional electrical, plumbing, and carpentry type repairs will be needed to repair doors, railing, fixtures, cabinets at the boathouse.

    Photo 22  

    Photo 23  

    Photo 24  

    Photo 26  

    18) Caulk was missing, deteriorated in some areas. For example, around windows. A qualified person should repair or replace as necessary. For more information, visit:
    http://www.reporthost.com/_docs/FPL_Caulking_Ins_Outs.pdf

    Photo 18  
     

    19) The exterior finish in some areas was failing, incomplete and/or substandard. A qualified contractor should prep and paint or stain areas as needed and as per standard building practices.

    Photo 13  
     

    20) Some exterior wall sections were obscured by vegetation and couldn't be fully evaluated.
     
    Roof / Attic Return to table of contents
    Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
    Condition of roof structure: Appeared serviceable
    Roof type: Hipped
    Age of roof surface(s): 3-5 years
    Source for building age: Inspector's estimate
    Roof inspection method: Partially traversed
    Condition of exposed flashings: Appeared serviceable
    Condition of attic: Appeared serviceable
    Attic inspection method: Traversed
    Roof structure type: Rafters
    Ceiling structure: Ceiling beams
    Ceiling insulation material: Fiberglass loose fill, Fiberglass roll or batt
    Ceiling insulation depth: 10 inches
    Ceiling insulation rating: 20
    Roof ventilation: Appears serviceable
    21) Many wood shakes were damaged or deteriorated, were missing or loose. Leaks may occur as a result. A qualified contractor should evaluate and repair as necessary. Location Boathouse

    Photo 32  
     

    22) Debris such as leaves, needles, seeds, etc. had accumulated on the roof. This is a conducive condition for wood destroying organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.

    Photo 35  

    Photo 4  

    23) Trees were overhanging roof and were within 10 feet of roof vertically. This is a conducive condition for wood destroying organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.

    Photo 36  
     

    24) Because of the roof configuration, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
     
    Garage / Carport Return to table of contents
    Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
    Type: Attached
    Condition of detached garage or carport structure: Appeared serviceable
    Condition of garage: Appeared serviceable
    Type of garage: Solid core, Glass
    Condition of garage floor: Appeared serviceable
    Condition of garage interior: Appeared serviceable
    25) Lighting at garage needs replacement bulbs or new fixtures.

    Photo 33  
     
     
    Electric Return to table of contents
    Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
    Electric service condition: Appeared serviceable
    Primary service type: Underground
    Condition of main service panel: Not determined
    Location of sub-panel #B: Interior
    Location of sub-panel #C: Boat house
    Location of main disconnect: Not determined
    26) One or more circuit breakers in panel #C were damaged. A qualified electrician should evaluate and replace circuit breakers or make repairs as necessary. This panel was arcing at inspection.

    Photo 30  
     

    27) Substandard wiring was found in the boathouse area. For example, vermin damage. This is a safety hazard. A qualified electrician should evaluate and repair as necessary and as per standard building practices. Location: boathouse

    Photo 25  
     

    28) One or more receptacles were broken, damaged. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair or replace as necessary. Location Boathouse

    Photo 21  
     

    29) One or more electric receptacles at the kitchen, bathroom(s), laundry room boat house had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
    http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf

    Photo 53  
     

    30) Some light fixtures were missing, damaged, deteriorated, loose, substandard. A qualified person should evaluate and repair or replace as necessary. Location Boathouse and rear patio

    Photo 12  

    Photo 27  

    31) The cover to panel #C was missing or not installed. This is a safety hazard for shock. A qualified person should replace missing components as necessary.
    32) Dryer outlet in laundry should be properly secured to the wall in this area.

    Photo 51  
     

    33) Some receptacle cover plates were missing. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary. Location kitchen sink

    Photo 47  
     

    34) One or more exterior receptacle covers were broken. This poses a safety hazard for shock. A qualified person should replace covers where necessary.

    Photo 3  

    Photo 9  

    35) The boat lift at the boat house is deteriorated. This fixture should be evaluated, repaired, and replaced if necessary by a qualified repair person.

    Photo 31  
     

    36) The legend for overcurrent protection devices (breakers or fuses) in panel #B was missing. Recommend installing, updating or correcting the legend as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.

    Photo 64  
     

    37) Electric panel(s) at location #A were not opened and fully evaluated due to the following conditions: panel locked. Recommend that repairs, modifications and/or cleanup be performed as necessary so panels can be opened and fully evaluated.

    Photo 15  
     

    38) Some bulbs in light fixtures were missing, inoperable. As a result, some light fixtures couldn't be fully evaluated. Recommend replacing bulbs to fully evaluate fixtures where necessary.

    Photo 50  
     
     
    Plumbing / Fuel Systems Return to table of contents
    Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
    Condition of service and main line: Appeared serviceable
    Condition of supply lines: Appeared serviceable
    Condition of drain pipes: Not determined
    Condition of waste lines: Not determined
    39) The sewage ejector pump was inoperable. A qualified contractor should evaluate and repair or replace as necessary. The test switch for this pump did not function at inspection. This pump and septic system should be evaluated and repaired by a licensed plumber.

    Photo 16  
     

    40) The sewer pump for the boat house was not functioning at inspection. The septic system for the boat house should be fully evaluated by a licensed plumber.
     
    Water Heater Return to table of contents
    Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
    Condition of water heater: Appeared serviceable
    Type: Tank
    Estimated age: 15 years est
    Energy source: Natural gas
    Capacity (in gallons): 40
    Manufacturer: Rheem
    41) Scorch marks were visible on the water heater cabinet above the combustion chamber opening. This may be a sign of improper venting, an improperly positioned burner, or other problems. A qualified contractor should evaluate and repair if necessary.

    Photo 61  
     

    42) No drain line was installed for the temperature-pressure relief valve. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. A qualified plumber should install a drain line as per standard building practices.

    Photo 55  
     

    43) The outer flame shield for the water heater combustion chamber was missing. This is a potential fire hazard. A qualified person should repair or replace as necessary.

    Photo 56  
     

    44) Active leaks were found at the TPR valve. A qualified plumber should evaluate and repair or replace as necessary.
    45) No water supply shut-off valve was visible for the water heater. A shut-off valve allows the supply to the water heater to be turned off when the water heater needs repair or replacement, while allowing the remainder of the plumbing system to be operable (toilets, sinks, etc.). Recommend having a qualified, licensed plumbing contractor determine if a water supply shut-off valve exists, and install one if it is missing.
    46) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be near this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
     
    Heating Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
    Condition of heating system: Appeared serviceable
    Heating type: Forced air
    Fuel type: Natural gas
    Manufacturer: Ruud
    Condition of burners: Appeared serviceable
    Condition of venting system: Appeared serviceable
    Condition of combustion air supply: Appeared serviceable
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    47) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit:
    http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

    48) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appeared to be near this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
     
    Cooling / Heat Pump Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
    Condition of cooling system and/or heat pump: Appeared serviceable
    Type: Split system
    Estimated age: 15 - 8 years
    Manufacturer: Ruud
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    49) The client should consider additional back up protection methods at the interior AC units to prevent water condensation drain clog damage. This would include drain pans/lines and/or water sensor shut offs.

    Photo 58  
     

    50) The condensate drain line was improperly sloped. Equipment damage, or water damage to surrounding structures may occur as a result. A qualified contractor should evaluate and repair as necessary.

    Photo 52  
     

    51) Refrigerant lines were sweating in one or more areas. A qualified contractor should evaluate and repair as necessary.

    Photo 57  
     

    52) Insulation for the outside condensing unit's refrigerant lines was missing, deteriorated in many areas. This may result in reduced efficiency and increased energy costs. A qualified person should replace insulation as necessary.

    Photo 7  
     

    53) Air filters were missing at one or more locations. As a result, unfiltered air will flow through the system, and equipment life and the indoor air quality may be reduced. Correctly sized filter(s) should be installed. If necessary, guides or retaining devices should be installed or repaired so filter(s) are securely anchored and gaps around edges are minimized.

    Photo 60  
     

    54) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
    55) Proper HVAC type tape should be used for all units in this house to prevent energy loss.

    Photo 63  
     

    56) The estimated useful life for most cooling systems and heat pumps is 10 to 15 years. This system appears to be near this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
     
    Fireplaces / Stoves / Chimneys Return to table of contents
    Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
    Condition of fireplaces, stoves: Appeared serviceable
    Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
    Chimney type: Stucco
    57) The stucco finish to the chimney is damaged. Cleaning and repair will be necessary.

    Photo 5  
     
     
    Kitchen Return to table of contents
    Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
    Condition of counters: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of garbage disposal: Appeared serviceable
    Condition of dishwasher: Appeared serviceable
    Condition of range, cooktop: Appeared serviceable
    Condition of refrigerator: Appeared serviceable
    58) Some cabinet surfaces, drawers and/or doors showed mis alignment . Repair as needed.

    Photo 49  
     
     
    Bathrooms / Laundry / Sinks Return to table of contents
    Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of toilets: Appeared serviceable
    Condition of bathtubs and related plumbing: Appeared serviceable
    Condition of shower(s) and related plumbing: Appeared serviceable
    Condition of ventilation systems: Appeared serviceable
    59) The "flapper valve" in the toilet at location # Guest bathroom did not reseat after flushing. Significant amounts of water can be lost through such leaks. A qualified plumber should evaluate and repair or replace components as necessary.

    Photo 65  
     

    60) Shower water stripping should be repaired as needed.

    Photo 67  
     
     
    Interior Rooms / Areas Return to table of contents
    Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
    Exterior door material: Wood, Glass
    Condition of exterior entry doors: Appeared serviceable
    Condition of interior doors: Appeared serviceable
    Type of windows: Wood
    Wall type or covering: Drywall
    Condition of walls: Appeared serviceable
    Ceiling type or covering: Drywall
    Condition of ceilings: Appeared serviceable
    Flooring type or covering: Carpet, Wood, Tile
    Condition of flooring: Appeared serviceable
    61) One or more exterior doors had minor damage. A qualified person should repair or replace as necessary.

    Photo 2  
     

    62) Thresholds at one or more exterior doors are damaged. A qualified person should repair, replace or install as necessary.
    63) Carpeting in one or more areas was loose. A qualified contractor should repair as necessary.

    Photo 54  
     

    64) Carpeting in some areas was deteriorated. A qualified contractor should replace as necessary

    Photo 59  
     

    65) Minor cracks and/or holes were found in walls in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.

    Photo 62  

    Photo 66  
     

    Photo 48  
     

     
    Please contact Jason Brown if you have any questions regarding this report.