Property Inspection Report
Client(s): Earl Creel
Property address: 199 Military Rd
Sumrall, MS
Inspection date: Thursday, January 07, 2010
This report published on 1/7/2010 7:12:45 PM CST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Inspector: Jason Brown
Structures inspected: Single Family Home
Age of building: 14 years
Inspection Fee: 200
Payment method: Invoiced
Present during inspection: Realtor(s)
Occupied: No
Temperature: Cold
Ground condition: Wet
Front of structure faces: North
Foundation type: Slab on grade
The following items are excluded from this inspection: Private sewage disposal system
 
Exterior Return to table of contents
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Composition wood clapboard, Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core wood, Glass panel
1) Soffit boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 2  

Photo 6  

2) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 3  

Photo 5  

3) One or more electric receptacles appear to have no power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Photo 4  
 
 
Roof Return to table of contents
Roof inspection method: Viewed from ground with binoculars
Roof type: Hipped
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 4 - 5 years
Roof ventilation: Adequate
4)   Trees at roof are causing damage to facia and shingles. These should be trimmed back to prevent further damage.

Photo 9  
 
 
Garage Return to table of contents

5) Some garage trim is missing or damage. These areas should be repaired.

Photo 16  
 

6) The garage vehicle door is damaged or deteriorated. A qualified contractor should evaluate and repair or replace the door as necessary.

Photo 15  
 
 
Attic Return to table of contents
Inspection method: Traversed
Roof structure type: Trusses
Ceiling structure: Ceiling beams
Insulation material: Cellulose loose fill
Insulation depth: 3 inches
Insulation estimated R value: 15
7) The ceiling insulation's R rating is significantly less than what's recommended for this area. Recommend having a qualified contractor install additional insulation as per standard building practices for better energy efficiency.

Photo 17  
 

8)   Some dry stains were evident in the area over the rear patio. This area should be monitored to insure repairs are correct.

Photo 20  
 
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 60
System ground: Ground rod(s) in soil
Smoke detectors present: Yes
9) The legend for overcurrent protection devices (breakers or fuses) in the main service panel is missing, unreadable or incomplete. Recommend installing, updating or correcting the legend as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.

Photo 1  
 
 
Water heater Return to table of contents
Estimated age: 14 years
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
Manufacturer: Rheem
10) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 18  
 
 
Heating and cooling Return to table of contents
Estimated age: 14 years
Primary heating system energy source: Electric
Primary heat system type: Heat pump
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts
Manufacturer: Ruud
Filter location: In return air duct above furnace
11) The estimated useful life for most heat pumps is 15 to 20 years. This heat pump appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 7  
 

12) Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.

Photo 8  
 

13) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.

Photo 19  
 

14) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
 
Fireplaces, woodstoves and chimneys Return to table of contents
Fireplace type: Metal prefabricated
Chimney type: Metal
15) One or more fireplace or woodstove hearths are less than 18 inches deep. This is a fire hazard. At a minimum, non-combustible hearth pad(s) should be installed. Ideally the hearth(s) should be modified as necessary or installed by a qualified contractor so they are at least 18" deep.

Photo 23  
 
 
Kitchen Return to table of contents

16) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

Photo 12  
 

17) The dishwasher appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, the dishwasher should be replaced, or a qualified appliance technician should evaluate and repair.

Photo 11  
 
 
Bathrooms Return to table of contents

18) One or more exhaust fans is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary.

Photo 14  
 

19) The "flapper valve" in one or more toilets did not reseat after flushing. Significant amounts of water can be lost through such leaks. A qualified plumber should evaluate and repair or replace components as necessary.
20) Caulk is missing or deteriorated along the base of one or more bathtubs, where flooring meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the floor structure.
 
Interior rooms Return to table of contents

21) Evidence of "light to moderate" rodent infestation was found in one or more areas. The client(s) may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygienist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).

Photo 10  
 

22) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.
23) Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.

Photo 21  

Photo 24  

24) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.

Photo 22  
 

25) Stains were found in one or more ceiling areas. However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner(s) about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain. If elevated moisture is found in the future, a qualified contractor should evaluate and repair as necessary.

Photo 13  
 

26) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
 