Brown Home Inspections


321 Serene Hills, Hattiesburg, MS 39402
Inspector: Jason Brown

Property Inspection Report
Client(s): Bryan Wallace
Property address: 123 Harmony
Columbia, MS
Inspection date: 11/16/2011
This report published on Wednesday, November 16, 2011 3:58:25 PM CST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage / Carport
Electric
Plumbing / Fuel Systems
Water Heater
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
 
General Information Return to table of contents
Time started: 10:00 AM
Time finished: 11:30 AM
Inspector: Jason Brown
Present during inspection: Client, Realtor
Client present for discussion at end of inspection: Yes
Weather conditions: Partly cloudy
Temperature: Warm
Ground condition: Damp
Inspection fee: 250
Payment method: Check
Buildings inspected: Single Family Home
Age of building(s): 20 years
Source for building age: Inspector's estimate
Front of building faces: East
Occupied: No
1) Propane was not available during the inspection (tank empty, shut off valve turned off, no tank installed, etc.). As a result, some appliances such as water heater(s), forced air furnace(s), gas fireplace(s), stove(s), range(s) and/or gas supply lines weren't fully evaluated. The inspector was unable to test for gas leaks.
 
Grounds Return to table of contents
Site profile: Minor slope
Condition of driveway: Appeared serviceable
Driveway material: Gravel
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Concrete
Condition of exterior stairs: Appeared serviceable
Exterior stair material: Masonry
2) One or more guardrails were missing. This is a safety hazard. Standard building practices require that they:

  • Be installed where walking surfaces are more than 30 inches above the surrounding grade
  • Be securely and permanently attached
  • Be at least 36 inches in height
  • Not be climbable by children
  • Not have gaps or voids that allow passage of a sphere equal to or greater than four inches in diameter

    A qualified contractor should evaluate and repair, replace or install guardrails as necessary, and as per standard building practices.

    Photo 4  
     

    3) Handrails at one or more flights of stairs were missing. This is a safety hazard. Standard building practices require that handrails be:

  • Installed at stairs with four or more risers
  • Sized and shaped so your hand can encircle them
  • Permanently and securely attached, and able to withstand a 200 pound force in any direction at any point
  • Continuous and extend for the entire flight of the stairs
  • Located between 30 and 38 inches above the leading edge of the stair treads

    A qualified person should repair, replace or install as necessary and as per standard building practices.
     
    Exterior / Foundation Return to table of contents
    Condition of wall covering: Appeared serviceable
    Apparent wall structure: Wood frame
    Wall covering: Brick veneer
    Foundation type: Not determined
    Foundation material: Concrete block
    Footing material: Not determined
    Condition of floor substructure: Appeared serviceable
    Pier or support post material: Wood
    Beam material: Solid wood
    Floor structure: Solid wood joists
    Crawl space inspection method: Traversed
    Insulation material underneath floor above: Fiberglass roll or batt
    Ventilation: Appears serviceable
    Vapor barrier present: Yes
    4) Carpenter bee damage was present at exterior. These areas should be treated and repaired. Multiple areas of the structure were occupied by wasps/hornets. This is a hazard and these areas should be treated as needed.

    Photo 1  

    Photo 50  

    5) Brick at garage walkway is loose. This is a trip hazard and should be repaired.

    Photo 16  
     

    6) Rot or water damage was found at one or more sections of soffits. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced.

    Photo 6  
     

    7) One or more exhaust duct end caps were missing. Their purpose is to prevent unconditioned air from entering the building, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and may pose a fire hazard. A qualified person should evaluate and repair as necessary.

    Photo 15  
     

    8) Floors in one or more areas were not level. Significant repairs may be needed to make floors level, such as repairs to the foundation. A qualified contractor should evaluate and make repairs as necessary.

    Photo 47  
     

    9) The vapor barrier in the crawl space was missing in some areas. This is a conducive condition for wood destroying organisms due to the likelihood of water evaporating into the structure from the soil. A qualified person should evaluate and replace or repair sections as necessary. Standard building practices require the following:

  • The soil below the vapor barrier should be smooth and free from sharp objects.
  • Seams should overlap a minimum of 12 inches.
  • The vapor barrier should lap up onto the foundation side walls.

    Better building practices require that:

  • Seams and protrusions should be sealed with a pressure sensitive tape.
  • The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.

    Photo 46  
     

    10) Crawlspace insulation has fallen in some areas. This condition should be repaired as needed.

    Photo 44  
     

    11) Caulk was missing in some areas. For example, around windows. A qualified person should repair or replace as necessary. For more information, visit:
    http://www.reporthost.com/_docs/FPL_Caulking_Ins_Outs.pdf

    Photo 10  
     

    12)   Loose cellulose debris should be removed from the crawlspace to inhibit wood destroying insects.

    Photo 45  
     
     
    Roof / Attic Return to table of contents
    Condition of roof structure: Appeared serviceable
    Roof type: Gable
    Age of roof surface(s): 5 years
    Source for building age: Inspector's estimate
    Roof inspection method: Viewed from ground with binoculars
    Condition of shingle and/or shake roof surface materials: Appeared serviceable
    Roof surface material: Asphalt or fiberglass composition shingles
    Condition of exposed flashings: Appeared serviceable
    Condition of attic: Appeared serviceable
    Attic inspection method: Traversed
    Roof structure type: Rafters
    Ceiling structure: Ceiling beams
    Ceiling insulation material: Fiberglass roll or batt
    Ceiling insulation depth: 8 inches
    Roof ventilation: Appears serviceable
    13) Trees were overhanging roof and were within 10 feet of roof vertically. This is a conducive condition for wood destroying organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.

    Photo 9  
     

    14) Attic is well insulated and ventilated. Knee walls support roof structure.

    Photo 53  
     
     
    Garage / Carport Return to table of contents
    Type: Attached
    Condition of garage floor: Appeared serviceable
    Condition of garage interior: Appeared serviceable
    15) The client should consider installing a vehicle door for increased security and to prevent moisture and pest intrusion.
     
    Electric Return to table of contents
    Electric service condition: Appeared serviceable
    Service voltage (volts): 120
    Service amperage (amps): 200
    Primary service overload protection type: Circuit breakers
    Condition of main service panel: Appeared serviceable
    Condition of sub: Appeared serviceable
    Location of main service panel #A: Garage
    Location of main disconnect: Breaker at top of main service panel
    Condition of branch circuit wiring: Serviceable
    16) Substandard wiring was found in the attic, AC closets, and under kitchen sink. For example, missing cover plates. This is a safety hazard. A qualified electrician should evaluate and repair as necessary and as per standard building practices.

    Photo 30  

    Photo 48  

    Photo 52  
     

    17) One or more electric receptacles at the kitchen had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
    http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf

    Photo 23  
     

    18) Some light fixtures and exterior ceiling fans were missing, damaged. Some fixtures may only need new bulbs. A qualified person should evaluate and repair or replace as necessary.

    Photo 3  

    Photo 25  

    Photo 28  
    Bathroom B

    Photo 38  

    Photo 40  

    Photo 41  

    19) One or more cover plates used at the building exterior were damaged, missing components. This is a potential safety hazard for shock and/or fire. A qualified electrician should evaluate and repair as necessary.

    Photo 7  

    Photo 14  

    20) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    Photo 59  
     

    21) The legend for overcurrent protection devices (breakers or fuses) in panel #A, B was missing. Recommend installing, updating or correcting the legend as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.

    Photo 13  
     
     
    Plumbing / Fuel Systems Return to table of contents
    Condition of service and main line: Appeared serviceable
    Condition of supply lines: Required repair, replacement and/or evaluation (see comments below)
    Condition of drain pipes: Required repair, replacement and/or evaluation (see comments below)
    Drain pipe material: Plastic
    Condition of waste lines: Appeared serviceable
    Waste pipe material: Plastic
    Vent pipe condition: Appeared serviceable
    Vent pipe material: Plastic
    Condition of fuel system: Not determined
    22) One or more outside faucets were leaking. This faucet was completely broken. . A qualified plumber should evaluate and repair as necessary.

    Photo 17  
     

    23) One or more leaks were found in drain fittings. A qualified plumber should evaluate and repair as necessary. Location: Crawl space in middle of area

    Photo 43  
     

    24) Some components of this property's plumbing system were "winterized" at the time of the inspection. The inspector was unable to fully evaluate the plumbing system. This may include toilets, sinks, bathtubs, showers, fixtures and supply, drain, waste and vent lines.
     
    Water Heater Return to table of contents
    Condition of water heater: Required repair, replacement and/or evaluation (see comments below)
    Type: Tank
    Energy source: Electricity, Natural gas
    Capacity (in gallons): 30, 40
    Manufacturer: Richmond
    25) The electric unit in the upstairs attic/storage area is non functioning. The heating elements have been damaged and scorching is present on the tank. This unit is badly deteriorated and should not be used. A replacement

    Photo 60  

    Photo 61  

    Photo 62  
     

    26) No drain line was installed for the temperature-pressure relief valve. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. A qualified plumber should install a drain line as per standard building practices.
    27) Water stains were found below the water heater. This may be a sign that the water heater is failing. A qualified plumbing contractor should evaluate and replace or repair the water heater if necessary.

    Photo 12  
     

    28) Significant corrosion was found at the supply pipes or fittings. A qualified plumber should evaluate and repair or replace as necessary.

    Photo 11  
     

    29) This water heater was not fully evaluated because the gas supply was off. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the appliance is operable. Note that as per the standards of practice for NACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to operate shut-off valves, pilot lights or overcurrent protection devices, or any controls other than "normal controls".
    30) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be beyond this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
     
    Cooling / Heat Pump Return to table of contents
    Condition of cooling system and/or heat pump: Appeared serviceable
    Type: Split system, Heat pump
    Estimated age: 5-10 years
    Approximate tonnage: 12 tons total
    Manufacturer: Trane Tempstar
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    Condition of air filters: Required repair, replacement and/or evaluation (see comments below)
    31) The downstairs master system's air handler was installed in an interior space, and no auxiliary condensate drain line or drip pan and drain were installed. Primary condensate drain lines often clog. When they do, water can overflow into finished living spaces below and cause damage. Recommend having a qualified contractor evaluate and install an auxiliary drain line and/or an auxiliary condensate drip pan and drain as per standard building practices.
    32) Some of the insulation on distribution ducts in the attic was substandard. A qualified person should evaluate and replace or repair as necessary for better energy efficiency.

    Photo 49  
     

    33) One or more air filters were located so that they're difficult to access. Recommend relocating filters as necessary to more accessible locations, such as behind return air grills in interior living spaces.

    Photo 54  

    Photo 64  

    34) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
    35) One or more air filters were dirty. A qualified person should filter(s) as necessary. Filters should be checked monthly and maintained as necessary in the future.

    Photo 55  
     
     
    Fireplaces / Stoves / Chimneys Return to table of contents
    Condition of fireplaces, stoves: Appeared serviceable
    Location #A: Den
    Fireplace type: Masonry
    Fuel type: Wood
    Condition of chimneys: Appeared serviceable
    36) The spark screen for the chimney flue opening at location #A was missing. Screens prevent the following:

  • Fire hazard from wood fire sparks and embers exiting flues
  • Wildlife (birds, rodents, raccoons, etc.) entering flues

    A qualified person should install or replace screening, or make repairs as necessary.
    37) Recommend that all wood burning appliances (fireplaces and stoves) and chimneys be evaluated by a specialist who is a a member of the Chimney Safety Institute of America or National Chimney Sweep Guild, and cleaned and/or repaired as necessary.
    38) The damper at location #A was damaged. A qualified contractor should evaluate and repair as necessary.

    Photo 65  
     
     
    Kitchen Return to table of contents
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Required repair, replacement and/or evaluation (see comments below)
    Condition of garbage disposal: Required repair, replacement and/or evaluation (see comments below)
    Condition of range, cooktop: Required repair, replacement and/or evaluation (see comments below)
    39) Substandard wiring was found for the garbage disposal. Wires had exposed splices. This is a potential safety hazard for shock. A qualified contractor should evaluate and repair as necessary.

    Photo 29  
     

    40) The gas cook top vent was stuck in the on setting. Several burner controls are broken. The appliance should be repaired or replaced as needed.

    Photo 18  
     

    41) Leaking or dripping was found at the kitchen sink faucet base. A qualified plumber should evaluate and repair as necessary.

    Photo 21  
     

    42) The garbage disposal was jammed. A qualified plumber or contractor should evaluate and repair or replace the food disposal as necessary.

    Photo 19  
     

    43) Biological staining was found under the sink. These areas should be properly tested and/or remediated as needed.

    Photo 20  
     

    44) The estimated useful life for most kitchen appliances is 10 to 15 years. One or more appliances (dishwasher, cooktop Oven) appeared to be near, at or beyond their service life. Recommend budgeting for replacements in the near future.

    Photo 22  
     
     
    Bathrooms / Laundry / Sinks Return to table of contents
    Location #A: Master
    Location #B: Downstairs Guest
    Location #C: South upstairs
    Location #D: Middle Upstairs
    Location #E: North upstairs
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Required repair, replacement and/or evaluation (see comments below)
    Condition of toilets: Required repair, replacement and/or evaluation (see comments below)
    Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
    Condition of shower(s) and related plumbing: Required repair, replacement and/or evaluation (see comments below)
    Condition of ventilation systems: Appeared serviceable
    Condition of laundry facilities: Appeared serviceable
    45) The sink drain at location #C had an active leak. A qualified plumber should evaluate and repair as necessary.

    Photo 36  
     

    46) Leaking or dripping was found at the bathtub at location #A. A qualified plumber should evaluate and repair as necessary. Faucet handle is missing at this location.

    Photo 33  
     

    47) The jetted tub at location #A was inoperable. A qualified contractor should evaluate and repair or replace as necessary.

    Photo 34  
     

    48) The sink drain stopper mechanism at location B# was missing. A qualified person should repair or replace as necessary.

    Photo 26  
     

    49) The shower head at location #A was missing. A qualified person should repair or replace as necessary.

    Photo 42  
     

    50) The toilet at location #C, D, E had no water supply and could not be fully evaluated. The shut-off valve(s) may be turned off, or repairs may be necessary. The client should ask the property owner about this, and have a qualified plumber evaluate and repair if necessary.

    Photo 32  

    Photo 37  

    51) Counter tops were damaged at location #B, D.

    Photo 27  

    Photo 39  
     
    Interior Rooms / Areas Return to table of contents
    Exterior door material: Wood, Glass
    Condition of exterior entry doors: Required repair, replacement and/or evaluation (see comments below)
    Condition of interior doors: Required repair, replacement and/or evaluation (see comments below)
    Type of windows: Aluminum
    Condition of windows: Appeared serviceable
    Wall type or covering: Drywall
    Condition of walls: Appeared serviceable
    Ceiling type or covering: Drywall
    Condition of ceilings: Appeared serviceable
    Flooring type or covering: Carpet
    Condition of flooring: Appeared serviceable
    52) Some windows that were built to open wouldn't open. A qualified person should evaluate and repair as necessary.

    Photo 63  
     

    53) Upstairs door frame is damaged. Repair as needed.

    Photo 57  
     

    54) Glass in one or more exterior doors was broken. A qualified contractor should replace glass where necessary. Location: Front door

    Photo 2  

    Photo 5  

    55) Some interior doors were damaged. A qualified person should repair or replace as necessary.

    Photo 31  

    Photo 35  

    56) Glass in one or more windows was cracked, broken and/or missing. A qualified contractor should replace glass where necessary.

    Photo 8  
     

    57) Some sections of flooring had minor deterioration or damage. For example, cracked tile. A qualified person should repair as necessary.

    Photo 24  
     

    58) Minor cracks in ceiling. These cracks do not appear to be structural in nature. Repair as needed.

    Photo 66  
     

    59) Carpeting in one or more areas was significantly stained or soiled. Recommend having carpeting professionally cleaned as necessary.

    Photo 51  

    Photo 58  

    Photo 67  
     

    60) Recommend cleaning and sealing grout in tile or stone flooring now and in the future as necessary to prevent staining and to improve waterproofing.
    61) Stains were found in one or more ceiling areas. However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain. If elevated moisture is found in the future, a qualified contractor should evaluate and repair as necessary.

    Photo 56  
     

     
    Please contact Jason Brown if you have any questions regarding this report.