HOME INSPECTION
Client(s): MR. and MRS. SMITH
Property address: 777 MAIN, CASPER, WYOMING
Inspection date: Tuesday, April 03, 2007
This report published on 4/3/2007 8:56:43 PM MDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major defectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Basement
Kitchen
Bathrooms
Interior rooms
 

General information 
Return to table of contents

Report number: 613
Structures inspected: Home
Type of building: Single family
Age of building: 50 years
Property owner's name: Mr. and Mrs. Jones
Time started: 8:00 AM
Time finished: 1:00 PM
Inspection Fee: $200.00
Payment method: Invoiced
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Front of structure faces: North
Main entrance faces: North
Foundation type: Finished basement
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
 
Exterior 
Return to table of contents

Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Metal
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
2)   Rear entrance door needs replacing.

Photo 2  
 

3)   Doors to out building need repair

Photo 5  
 
 
Roof 
Return to table of contents

Roof inspection method: Traversed
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Gutter & downspout material: Aluminum
Roof ventilation: None visible
4) The roof surface material appears to be near the end of its service life and will likely need replacing in the near future, even with repairs. The client(s) should budget for a replacement roof surface, and may want to have a qualified roofing contractor evaluate and attempt to issue a "5 year roof certificate".
5) Roofing nails in one or more areas have loosened or backed out. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails and applying sealant.
 
Attic 
Return to table of contents

Inspection method: Viewed from hatch
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass roll or batt
Insulation depth: 4-6"
Insulation estimated R value: 8-12
6) Ventilation is substandard in the attic. Inadequate attic ventilation may result in high attic and roof surface temperatures, reduce the life of the roof covering materials and increase cooling costs. High levels of moisture are also likely, and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of attic space. Vents should be evenly distributed between soffits, ridges and at corners to promote air circulation. A qualified contractor should evaluate and install vents as per standard building practices.
 
Electric service 
Return to table of contents

Primary service type: Overhead
Primary service overload protection type: Circuit breakers
Service amperage (amps): 100
Service voltage (volts): 120/240
Location of main service switch: Kitchen
Location of sub panels: Laundry room
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Copper
System ground: Copper
Main disconnect rating (amps): 100
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: No
 
Water heater 
Return to table of contents

Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: A.O. Smith
Model: AO -40 G
Water temperature (degrees Fahrenheit): 120
7) The water heater flame is yellow rather than blue. This may be caused by scale on top of the burner, a dirty burner orifice, the flue being clogged, and/or improper gas pressure. A qualified contractor should evaluate and repair as necessary.
8) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
 
Heating and cooling 
Return to table of contents

Estimated age: 25-50 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: N/A
Primary Air conditioning type: N/A
Distribution system: Sheet metal ducts
Manufacturer: Coleman
Model: C-100-G
Filter location: In return air duct below furnace
Last service date: unknown
9) Because of the age and/or condition of this furnace, recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
10) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
11) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 4  
 

12) One or more rooms' interior doors have no gap below, or have a gap less than 3/4". As a result, return air flow out of the room is restricted with closed door(s) and the heating/cooling system on. This may result in the heating and/or cooling system having a reduced efficiency and higher energy costs. To allow adequate return air flow, recommend either trimming the bases of doors as necessary to maintain a 3/4" gap below, or leaving doors open while the heating or cooling system is in operation.
 
Plumbing and laundry 
Return to table of contents

Water pressure (psi): 75
Location of main water shut-off valve: launbdry room
Location of main water meter: laundry room
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Copper
Drain pipe material: Copper
Waste pipe material: Cast iron
13) No ground fault circuit interrupter (GFCI) protection device is visible for the sump pump electric supply. A qualified electrician should determine if a GFCI protection device (receptacle or circuit breaker) exists for the sump pump and install one if missing to reduce the danger of electric shock.
14) The clothes dryer exhaust duct is broken or disconnected in one or more places. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A qualified contractor should evaluate and make permanent repairs as necessary. For more information, visit http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
15) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
 
Fireplaces, woodstoves and chimneys 
Return to table of contents

Fireplace type: Metal prefabricated
Woodstove type: Metal
Chimney type: Metal
16) Soot deposits were found on the glass in one or more gas fireplaces and/or woodstoves. This may be an indication of incomplete combustion. A qualified contractor should evaluate and make repairs as necessary, such as adjusting or repairing the burners and/or nozzles. Also the glass should be cleaned with a gas appliance ceramic glass cleaner. Ammonia-based products, such as common glass cleaners should not be used since they may cause damage or etching to the glass.
 
Basement 
Return to table of contents

Insulation material underneath floor above: None visible
Pier or support post material: Bearing wall
Beam material: Solid wood
Floor structure above: Solid wood joists
 
Kitchen 
Return to table of contents


17) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
18) The refrigerator appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, the refrigerator should be replaced, or a qualified appliance technician should evaluate and repair.
19) Laminate countertop material is loose or delaminating in one or more areas. A qualified contractor should evaluate and repair as necessary.
20) No range hood is installed over the range or cook top. Ventilation and/or lighting may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor install a vented and lighted range hood, with the exhaust fan configured so as to vent outdoors.
21) One or more handles are missing from water shut-off valves. Handles should be replaced where missing.
22) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring.
23) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.
24) One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
 
Bathrooms 
Return to table of contents


25) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
26) One or more toilets are loose, and evidence of damage or possible damage to the floor structure below was found. For example, elevated levels of moisture, soft floor structure, and/or dark staining at vinyl flooring around the base of the toilet(s). A qualified contractor should remove toilet(s) where necessary for further evaluation and repairs. The floor structure and flooring material below may need repair or replacement. Adequate time should be allowed for enclosed, wet floor structures to dry out after repairs are made and before floor cavities are closed off to prevent mold growth.
27) One or more cabinets and/or drawers are damaged and/or deteriorated. A qualified contractor should evaluate and repair or replace cabinets and/or components as necessary.

Photo 3  
 
 
Interior rooms 
Return to table of contents


28) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
29) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
30) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons. Tile need repair