Bluegrass Home Inspections, Inc

Website: http://www.reporthost.com/bluegrass
Email: bluegrass@iglou.com
Phone: (502) 552-2101
107 Fenley Ave. #O-1 
Louisville, KY 40207
Inspector: Michael Wirth

Home Inspection Report
Client(s): Sample Client
Property address: 1234 Anystreet Dr
Louisville, KY 40229
Inspection date: Tuesday, October 20, 2009
This report published on 2/4/2010 11:35:45 AM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Bathrooms
 
General information Return to table of contents
Report number: 091020A
Inspector's name: Michael Wirth, HI-2043
Type of building: Single family
Age of building: 29
Time started: 2:00 PM
Inspection Fee: $200.00
Present during inspection: Client(s)
Occupied: No, but furnishings and stored items are present
Weather conditions: Clear
Temperature: Cool
Ground condition: Damp
Main entrance faces: West
Foundation type: Slab on grade
The following items are excluded from this inspection: Shed
 
Exterior Return to table of contents
Wall covering: Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete aggregate
Exterior door material: Solid core steel
Wall covering: Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete aggregate
Exterior door material: Solid core steel
1) House storage door is delaminated and has peeling paint.

Photo 14  
Delamination and peeling paint of house storage door
 
 
Roof Return to table of contents
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 10-15
Roof ventilation: Adequate
2) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

Photo 13  
Tree limb over house
 
 
Attic Return to table of contents
Inspection method: Viewed from hatch
Roof structure type: Trusses
Insulation material: Fiberglass loose fill
Insulation depth: 10-12
 
Electric service Return to table of contents
Primary service type: Overhead
Primary service overload protection type: Circuit breakers
Service amperage (amps): 125
Service voltage (volts): 120/240
Location of main disconnect: Top bank of breakers in main service panel (split bus)
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil, Cold water supply pipes
Main disconnect rating (amps): Not applicable, no single main disconnect
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes
3) One or more overcurrent protection devices (circuit breakers or fuses) are "double tapped", where 2 or more wires are clamped in a terminal designed for only one wire. This is a safety hazard since the bolt or screw may tighten securely against one wire, but leave others loose. Arcing, sparks and fires may result. A qualified electrician should evaluate and repair as necessary.

Photo 3  
Multiple wires on single breaker
 

4) One or more circuit breakers in the main service panel are damaged and/or burned. A licensed electrician should evaluate and replace circuit breakers or make repairs as necessary.

Photo 2  
Broken tab on 50 Amp (range) breaker
 

5) Outlet in laundry room has reverse polarity. The hot and neutral wires are connected on the wrong terminals of the outlet. A licensed electrician should evaluate and replace circuit breakers or make repairs as necessary.
 
Water heater Return to table of contents
Estimated age: 10
Energy source: Natural gas
Capacity (in gallons): 30
Manufacturer: Richmond
 
Heating and cooling Return to table of contents
Estimated age: 13
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts, Flexible ducts
Manufacturer: Carrier
Filter location: In return air duct below furnace
6) Client stated the Sellers Disclosure indicated the AC compressor was replaced since 2003. Data plate of unit indiacates it was manufactered in 1996. Obtain further verification from owner.

Photo 7  
AC Data plate indicates 1996 manufacture
 
 
Plumbing and laundry Return to table of contents
Location of main water shut-off valve: In laundry by water heater
Water service: Public
Supply pipe material: Copper
Waste pipe material: Plastic
7) Rusted pipes at gas meter could result in pinhole gas leaks. Clean and paint the pipes as soon as possible to prevent further damage.

Photo 8  
Rusted pipes at gas meter
 
 
Bathrooms Return to table of contents

8) Handheald shower head not secure to wall & water leaks/sprays when shower head is moved.

Photo 15  
Leak at shower head
 
 

Photo 1  
Front of House

Photo 4  
Storage shed (not inspected)

Photo 5  
Rear of House

Photo 6  
AC Compressor

Photo 9  
Furnace

Photo 10  
Furnace with cover removed

Photo 11  
Water Heater

Photo 12  
Main water shutoff

 
Bluegrass Home Inspections, Inc.