Home Inspection Report
Client(s): Jill Calhoun
Property address: 813 Coastal Court
Los Banos Ca 93635
Inspection date: Tuesday, February 12, 2008
This report published on 2/15/2008 2:15:19 PM PST

View summary page

THIS AGREEMENT made this 11th day of February, 2008,

By and between:

Building Industry Consulting & Inspection Services, Los Banos Ca 93635 (Hereinafter “INSPECTOR”) and the

undersigned Jill Calhoun 1020 Fifth Street Appt #11 Los Banos CA 93635 (hereinafter “CLIENT”), collectively referred to herein as “the parties.”

The Parties Understand and Voluntarily Agree as follows:

1. INSPECTOR agrees to perform a visual inspection of the home/building and to provide CLIENT with a written inspection report identifying the defects that INSPECTOR both observed and deemed material. INSPECTOR may offer comments as a courtesy, but these comments will not comprise the bargained-for report. The report is only supplementary to the seller’s disclosure.
2. Unless otherwise inconsistent with this Agreement or not possible, INSPECTOR agrees to perform the inspection in accordance to the current Standards of Practice of the National Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm. CLIENT understands that these standards contain certain limitations, exceptions, and exclusions.
3. The inspection and report are performed and prepared for the use of CLIENT, who gives INSPECTOR permission to discuss observations with real estate agents, owners, repairpersons, and other interested parties. INSPECTOR accepts no responsibility for use or misinterpretation by third parties. INSPECTOR’S inspection of the property and the accompanying report are in no way intended to be a guarantee or warranty, express or implied, regarding the future use, operability, habitability or suitability of the home/building or its components. Any and all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are expressly excluded by this Agreement.

4. INSPECTOR assumes no liability for the cost of repair or replacement of unreported defects or deficiencies either current or arising in the future. CLIENT acknowledges that the liability of INSPECTOR, its agents, employees, for claims or damages, costs of defense or suit, attorney’s fees and expenses and payments arising out of or related to the INSPECTOR’S negligence or breach of any obligation under this Agreement, including errors and omissions in the inspection or the report, shall be limited to liquidated damages in an amount equal to the fee paid to the INSPECTOR, and this liability shall be exclusive. CLIENT waives any claim for consequential, exemplary, special or incidental damages or for the loss of the use of the home/building even if the CLIENT has been advised of the possibility of such damages. The parties acknowledge that the liquidated damages are not intended as a penalty but are intended (i) to reflect the fact that actual damages may be difficult and impractical to ascertain; (ii) to allocate risk among the INSPECTOR and CLIENT; and (iii) to enable the INSPECTOR to perform the inspection at the stated fee.

5. INSPECTOR does not perform engineering, architectural, plumbing, or any other job function requiring an occupational license in the jurisdiction where the inspection is taking place, unless the inspector holds a valid occupational license, in which case he/she may inform the CLIENT that he/she is so licensed, and is therefore qualified to go beyond this basic home inspection, and for additional fee, perform additional inspections beyond those within the scope of the basic home inspection. Any agreement for such additional inspections shall be in a separate writing or noted here: _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________.

6. In the event of a claim against INSPECTOR, CLIENT agrees to supply INSPECTOR with the following: (1) Written notification of adverse conditions within 14 days of discovery, and (2) Access to the premises. Failure to comply with the above conditions will release INSPECTOR and its agents from any and all obligations or liability of any kind.
7. The parties agree that any litigation arising out of this Agreement shall be filed only with the NACHI Alternate Debt Resolution Service through the Certification company in which the INSPECTOR belongs NACHI (National Association of Certified Home Inspectors) In the event that CLIENT fails to prove any adverse claims against INSPECTOR, CLIENT agrees to pay all costs, expenses and fees of INSPECTOR in defending said claims. Initial _________
8. If any court declares any provision of this Agreement invalid or unenforceable, the remaining provisions will remain in effect. This Agreement represents the entire agreement between the parties. All prior communications are merged into this Agreement, and there are no terms or conditions other than those set forth herein. No statement or promise of INSPECTOR or its agents shall be binding unless reduced to writing and signed by INSPECTOR. No change or modification shall be enforceable against any party unless such change or modification is in writing and signed by the parties. This Agreement shall be binding upon and enforceable by the parties and their heirs, executors, administrators, successors and assignees. CLIENT shall have no cause of action against INSPECTOR after one year from the date of the inspection.
9. Payment of the fee to INSPECTOR (less any deposit noted above) is due upon completion of the on-site inspection. The CLIENT agrees to pay all legal and time expenses incurred in collecting due payments, including attorney’s fees, if any. If CLIENT is a corporation, LLC, or similar entity, the person signing this Agreement on behalf of such entity does personally guaranty payment of the fee by the entity.
CLIENT HAS CAREFULLY READ THE FOREGOING, AGREES TO IT, AND ACKNOWLEDGES RECEIPT OF A COPY OF THIS AGREEMENT.
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 813 Coastal Court
Structures inspected: Home and property
Property owner's name: Jill Calhoun
Pictures: Please scroll down to pictorial as they are captioned for your convience.
Age of building: 8-1/2 years
Time started: 9:00AM
Time finished: 11:30AM
Inspection Fee: $350.00
Payment method: Invoiced
Present during inspection: Client ( Buyer ), and one of the Property owners ( Seller )
Occupied: Yes
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry conditions with some dampness in shaded areas
Type of building: A well maintained Single Family 4 Bedroom 2 Bath 2 Car Garage Home situated within Los Banos city limits. Gas and Electrical services provided to this property are from Pacific Gas and Electric, All other services are provided by Los Banos City ( Water, Trash pick up, and Road Maintenance )
Front of structure faces: North
Main entrance faces: North
Foundation type: Slab on grade
Alarm system: ADT alarm system is hard wired in to this home. It was not tested and owner will leave the system. If the new owner wants to restablish it all the prewiring is complete.


1)   Some wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items. Because of this some areas couldn't be fully evaluated.
 
Exterior Return to table of contents
Footing material: Poured in place concrete, Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stucco This home has very minor cracking at window corners, and in a few wall sections that are due to settlement and do not require attention.
Driveway material: Poured in place concreteNo cracking or trip hazzards found at time of inspection.
Sidewalk material: Poured in place concrete Slopes away from home, and is in excellent shape.
Exterior door material: Solid core fiberglass
Windows: Vinyl dual glazed horizontal sliding windows. Tested and open/closed easily. Locking devices worked well.
2) Wooden fencing used as retaining walls have minor amounts of rot and/or damage by wood destroying insects. The client(s) should monitor such walls in the future for continued rotting and/or damage. Repairs and/or replacement by a qualified contractor may be necessary in the future.
3)   Fences and/or gates are damaged and/or deteriorated in some areas. A qualified contractor should evaluate and make repairs or replace sections as necessary.
4) Soil is in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below. This is apparent in the front of home
5) One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
    6)   One or more large trees are very close the foundation. Tree roots can cause significant structural damage to foundations. Recommend having a qualified tree service contractor or arborist inspect trees as necessary to prevent damage to the structure's foundation.
    7)   The perimeter grading slopes away from the structure in all areas. This will keep water from accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. This home meets or exceeds the Recommended grading so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet. This is not the case in the aforementioned garden area left of the fron entryway.
    8) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
    9) Recommend cleaning deck(s) and railing(s) and treating with a preservative claiming to waterproof, block ultraviolet light, and stop mildew. Consumer Reports recommends these products:

  • Cabot Decking Stain and PTW Stain
  • Olympic Water Repellent Deck Stain
  • Thompson's House and Deck Stain
  • Wolman PTW Deck Stain
  • Akzo Sikkens Cetol DEK
  • Benjamin Moore Moorwood Clear Wood Finish
  • DAP Woodlife Premium
  • Olympic Natural Look Protector Plus
    10)   The substructure of the deck is excluded from the inspection due to limited access because of the low height.
    11)   The exterior of this home is very well maintained. The electrical outlets, water spichots, gutters, and gutter downspouts work properly. The downspout drains terminate down grade to frontyard and show no signs of clogging. The Concrete walkways, driveway, and stucco show only minor cracking as allowed in the settlement of the property.
     
    Roof Return to table of contents
    Roof inspection method: Viewed from eaves on ladder
    Roof type: Gable, Cross gable, Cross-hipped
    Roof covering: Concrete tile This roof is only approximatley 9 years old and has a servicable life of approximatley 40 years if properly maintained. It is excellent condition at this time.
    Estimated age of roof: 9 years.
    Gutter & downspout material: Galvanized steel
    Roof ventilation: Adequate
    12) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.
    13) Debris such as leaves, needles, seeds, etc. have accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.
    14) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.
    15) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
    16)   Media cables terminate at base of chimney, and appear to only be caulked and or sealed to prevent water intrusion
    17)   Because of the roof covering type and/or the configuration of the roof, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
     
    Garage Return to table of contents

    18)   Weatherstrip around or at the edge of the garage-to backyard door is missing. It should be installed where missing.
    19)   The interior of this garage is finished drywall, and textured. Roll up door operated by an automatic opener equipped with an infrared sensor that meets safety requirements. ( stopping when activated, and reversing when obstructed. ) GFCI outlets function normal when tripped.
    20)   Much of the garage, including areas around the interior perimeter and in the center are excluded from this inspection due to lack of access from stored items.
     
    Attic Return to table of contents
    Inspection method: Viewed from hatch. Area viewed was dry, and void of water intrusion past or present.
    Roof structure type: TrussesWood. The roof sheeting showed numerous shiners ( staples breaking through surface from installing roof felt ) No apperant rust or corrosion.
    Ceiling structure: Trusses
    Insulation material: Fiberglass roll or batt, Cellulose loose fill
    Insulation depth: 8 inc hes plus
    Insulation estimated R value: R30
    Media Cables: Inside attic crawlspace above opening are the media cables for the entire home, including prewire of surround system.
     
    Electric service Return to table of contents
    Primary service type: Underground
    Primary service overload protection type: Circuit breakersGFCI are located in bathrooms, kitchen, and garage worked properly when tripped.
    Service amperage (amps): 200The electrical service of this home is current to the laws of ICC/UBC at the time of its construction, and appear to be in proper working order at time of this inspection.
    Service voltage (volts): 120/240
    Location of main service switch: Right side of home ( facing it from the street )
    Location of sub panels: Right side of home ( facing it from the street )
    Location of main disconnect: No single main disconnect, use all breakers in main service panel
    Service entrance conductor material: Copper
    System ground: Ground rod(s) in soil
    Main disconnect rating (amps): Not applicable, no single main disconnect
    Branch circuit wiring type: Non-metallic sheathed
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: YesIn every room except Bathrooms
    21)   The inspector didn't remove the main service panel cover due to the equipment being energized. This is a severe safety hazard due to the risk of shock. The panel wasn't fully evaluated.
     
    Water heater Return to table of contents
    Estimated age: 9 yaers
    Type: TankInlet / out let valves showed little corrosion and appear to be in good working order.
    Energy source: Natural gas
    Capacity (in gallons): 40
    Manufacturer: N/A Covered in insulated blanket
    Model: N/A Covered in insulated blanket
    22)   Stored items, furnishings and/or debris blocked access to the water heater. These items can pose a threat of fire, and reccomend removing. The inspector was unable to fully evaluate the water heater.
    23)   A permanently installed insulated jacket is installed on the water heater. It obscures the manufacturer's information label and most of the water heater. The inspector was unable to fully evaluate the water heater.
    24)   The water heater is located inside a permanently installed enclosure with proper venting. Pressure relief valve terminates to drain outside away from closet. The door to closet open to exterior of home ans is well vented.
     
    Heating and cooling Return to table of contents
    Estimated age: 9 Years
    Primary heating system energy source: Natural gas
    Primary heat system type: Forced air, Down draft
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Flexible ducts
    Manufacturer: Bryant
    Filter location: In return air duct below furnaceHallway
    Last service date: N/A
    25)   The furnace was on at the time of the inspection, and cycled on / off twice during my time insde of home. No signs of discolored walls around vents or registers suggesting is operating normally at the time of inspection.
    26)   The air conditioning system's unit was shut off at the time of the inspection. For example, the electric supply was turned off. As a result, the inspector was unable to fully evaluate this unit. In conversation with owner the system operates very well. Inspection of coils, Condensation drain and filters showed no signs of excessive wear, or dirt buil up to suggest otherwise.
     
    Plumbing and laundry Return to table of contents
    Water pressure (psi): 40lbs taken at fron spichot
    Location of main water shut-off valve: Front left of home ( Facing from street )
    Location of main water meter: Sidewalk in front of home
    Location of main fuel shut-off: Right side of house ( facing from street )
    Water service: Public
    Service pipe material: Copper
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    Central Vacum System: Located in Garage with 3 outlets in the interior of home. This system was tested and functioned properly.
    Sinks: The sinks throughout this home worked normal with adaquate flow vs. drain. Their appeared to be some very minor calcium build up on a few but pose no problem. Monitor over time.
    27)   Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection. The area in wich they are installed appeared clean and showed minor build up of lent. The ceramic tile floor showed no visable water staining.
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Fireplace type: Masonry with metal linerFactory Built, with a brick hearth, and mantel.
    Chimney type: Factory Built, stucco clad, Galvinized spark arrestor.
    28)   This fireplace has never been used and is in orginal condition. I suggest a qualified chimney sweep review the system before lighting first fire do to period of time ( 9years ) of inactivity
     
    Kitchen Return to table of contents
    Appliances: The appliances are Whirlpool, and run on natural Gas. Stove functioned normally, Oven was not tested. ( appeared to need a cleaning ) Garabage disposal appeared new and work as designed. Microwave was clean and operated normally.
    29)   Oven show signs of use and is in need of cleaning. This is a self cleaning unit and suggest following the manufactures directions when doing so.
    30)   The dishwasher drain line is not configured with a "high loop" or "air gap". A high loop is created by routing the drain line up to the bottom surface of the counter top above, and securely fastening it to that surface. It is meant to prevent water from siphoning out of the dishwasher, and to prevent water from the sink drain or food disposal from entering the dishwasher. Some dishwashers have a built-in high loop where one is not required to be configured in the drain line. The clients should try to determine if a high loop is required for this brand and model of dishwasher (review installation instructions, etc.). If one is required, or it cannot be determined if one is not required, then a qualified contractor should install a high loop as per standard building practices.

    Also, no "air gap" is installed. Air gaps are another device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.

     
    Bathrooms Return to table of contents

    31) Master Bathroom floor tile cracked. Reccomend replacing using a qualified flooring specialist.
    32)   Recommend cleaning and sealing grout in tile or stone flooring now and in the future as necessary to prevent staining and to improve waterproofing.
    33)   One or more toilet bowls, show some sign of minor build up from water or condensation leak at the connection to valve. This appears to have happened some time ago and poses no problem.
    34) Master Bathroom shows some discoloration on ceiling of Tub/Shower. This is possibly due to excessive moisture from use. Reccomend repainting over time. At this time it poses no problem and would wipe away execess moisture after each use.
    35)   Tub/Showers have good water flow and drain with ease. Their is no build up of mold, or staining as both systems are very well maintained!
     
    Interior rooms Return to table of contents
    Flooring: Wood pergo type flooring in kitchen is in excellent shape. The high low berber carpet is in very good condition with minor stains. ( recommend a qualified carpet cleaning. ) The bathroom wet areas are covered with ceranic tile grouted in place, and appear to be in very good condition. ( with exception of cracked tile in Master ) Recommend Clean and seal to prolong longevity.
    36)   Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    37)   Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    38)   This structure was built in 1999 and has been very well maintained. The GFCI's, HVAC registers, towelbars, door stops, ceiling fans, lights, plugs, doors, and windows were evualated. The results were excellent as everything worked as intended, and only showed wear based on their age. The only drawback at time of inspection was the amount of furniture and stored items limiting access to some areas.
     

    Photo 1  
    Interior Ceiling Fan ( typical throughout home )

    Photo 2  
    Interior of Home

    Photo 3  
    Interior great room and entry way towards front door

    Photo 4  
    Interior of home

    Photo 5  
    Interior of home Brick fireplace, and hearth.

    Photo 6  
    Interior of home

    Photo 7  
    Interior of home

    Photo 8  
    Interior of home Kitchen sink utilities, and undercabinet plumbing.

    Photo 9  
    Kitchen area

    Photo 10  
    Kitchen Area

    Photo 11  
    Interior Hallway

    Photo 12  
    HVAC Return Air filter system

    Photo 13  
    Main Batroom sink plumbing, and connections

    Photo 14  
    Main Bathroom toilet plumbing connections

    Photo 15  
    Main Bathroom Sink, Cabinet, and fixtures.

    Photo 16  
    Main Bathroom toilet area, and ceramic tile floor

    Photo 17  
    Laundry area ( both washer and dryer are Electric )

    Photo 18  
    Washer hot and cold outlets, and washer waste drain.

    Photo 19  
    Washer/Dryer back side showing Ceramic tile floor

    Photo 20  
    Dryer back side showing 220 electrical hook up, and dryer vent line.

    Photo 21  
    Interior office ( 4th room )

    Photo 22  
    Smoke detector typical throughout each room in house except bathrooms

    Photo 23  
    Bedroom # 3

    Photo 24  
    Bedroom # 2

    Photo 25  
    Master Bedroom

    Photo 26  
    Master Bedroom

    Photo 27  
    Master Bedroom

    Photo 28  
    Master Bedroom

    Photo 29  
    Master Bathroom Toilet connections

    Photo 30  
    Master Bathroom Toilet connections, and ceramic tile floor.

    Photo 31  
    Master Bathroom showing cracked tile. ( Minor defect )

    Photo 32  
    Master Bedroom walk in closet

    Photo 33  
    Master bathroom Tub/Shower combo

    Photo 34  
    Master bathroom Tub/Shower combo, and fixture

    Photo 35  
    Master bathroom under sink cabinet plumbing connections #1

    Photo 36  
    Master bathroom under sink cabinet plumbing connections #2

    Photo 37  
    Master Bathroom dual sink set up.

    Photo 38  
    Window. Dual Glaze typical vinyl slider with sill.

    Photo 39  
    Fireplace flue view looking up to sparkarrestor ( never used )

    Photo 40  
    Fireplace Cinder block construction, with metal grate.

    Photo 41  
    Garage finished drywall with Automatic garage door opener equipped with safety back-up infrared system.

    Photo 42  
    Garage door to house Solid core with self closing hinges

    Photo 43  
    Garage solid core metal door to outside. ( needs weaterstripping )

    Photo 44  
    Garage sink plumbing ( P trap )

    Photo 45  
    Garage sink plumbing fixture connections

    Photo 46  
    HVAC gas on / off valve located above attic access door

    Photo 47  
    Attic Access area showing media cables

    Photo 48  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 49  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 50  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 51  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 52  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 53  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 54  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 55  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 56  
    HVAC Insulated flexable ducting, trusses, Blown-in insulation, rolled in fiberglass insulation, OSB plywood sheeting, Plumbing Vent lines ( Black PVC ) ceiling fan vent lines ( flexible metal ), and roof air vents

    Photo 57  
    HVAC air transfer unit

    Photo 58  
    HVAC refirgent lines to condensor of this split system

    Photo 59  
    Hvac Manuel located above attic access.

    Photo 60  

    Photo 61  
    Exterior typical stucco, electrical outlet, and concrete patio.

    Photo 62  
    Exterior wood soffit, stucco, and Gable view.

    Photo 63  
    Exterior left side walk way.

    Photo 64  
    Exterior gutter downspout to drain

    Photo 65  
    Exterior Gutter and downspout typical of this home

    Photo 66  
    Water Heater pressure relief overflow drain.

    Photo 67  
    Water Heater ( Gas 40gal. capacity )

    Photo 68  
    HVAC Condensor drain

    Photo 69  
    Exterior Stucco cracking typical of this home. Minor issue due to settlement.

    Photo 70  
    Exterior walkway in back of home, and patio overhang.

    Photo 71  
    Exterior patio door mud sill missing below door sill

    Photo 72  
    Exterior wood deck, hand rail, wood fence, in back yard.

    Photo 73  
    Exterior wood deck ( Patio )

    Photo 74  
    Exterior gable end and typical stucco finish.

    Photo 75  
    Exterior Stucco, Factory Built Fireplace chimney, Gutter, and wood fence Gate.

    Photo 76  
    HVAC Split system condensing coil

    Photo 77  
    Exterior Backyard Landscape

    Photo 78  
    Exterior Backyard Landscape

    Photo 79  
    Exterior Backyard Landscape

    Photo 80  
    Central vac system outlet

    Photo 81  
    Front Door ( Fiberglass )

    Photo 82  
    Exterior roll up aluminum Garage door, and Driveway.

    Photo 83  
    Exterior Front view

    Photo 84  
    Exterior front view

    Photo 85  
    Exterior Front view

    Photo 86  
    Exterior Automatic sprinkler valves. Front yard

    Photo 87  
    Exterior water spichot in front of home with anti syphon valve. ( tested 40lbs water pressure. )

    Photo 88  
    Exterior Landscape front yard

    Photo 89  
    Exterior Drain for gutters and landscape for right side of home and backyard.

    Photo 90  
    Telephone and Utility boxes. Front yard.

    Photo 91  
    Exterior. Water meter and shut off located on sidewalk in front of home.

    Photo 92  
    Exterior Gutters, Concrete Sidewalk, wood fence. ( Typical for home )

    Photo 93  
    Exterior gutter, Roof Jacks, Plumbing Vents, and Tile roof.

    Photo 94  
    Roof Gable end, Gable end Vent, and Concrete roof tile ridge cap.

    Photo 95  
    Roof Valley to ridgeline. View from front

    Photo 96  
    Roof flashing at chimney

    Photo 97  
    Roof at termination of chimney. Media Cables

    Photo 98  
    Chimney with spark arrester

    Photo 99  
    Roof (Concrete Tile )

    Photo 100  
    200amp Electric service located on West side.

    Photo 101  
    Gas Meter located on West side of Home
     

     