B-E Home Inspections

Website: http://www.reporthost.com/behi
Company email: kjones@in.nachi.org
Inspector's email: jones.ken@comcast.net
Phone: (219) 878-4120

Summary Page

Your Property Inspection Report
Client(s): Ms. Julie Vanes
Property address: 715 D Street
LaPorte, IN 46350
Inspection date: Thursday, March 20, 2008

This summary page published on 3/20/2008 3:17:51 PM CDT

Return to report

When viewing this summary page, it is important to note that the summary is not the entire report and is provided as a convenience and is not intended to replace the complete report.

The complete report may include additional information and/or concerns to the client. It is recommended that the report be reviewed in its entirety.

The items numbers below correspond to the order they are found in the main body of this report. Each summary item is further explained in comments found in the main body of this report.

Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death. 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
EvaluateRecommend evaluation by a specialist. 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in serviceable condition 
CommentFor your information, Inspector comments and recommendations 
 
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

1) Grounds:   - Handrails at one or more flights of stairs were missing. This is a safety hazard. Standard building practices require that handrails be:

  • Installed at stairs with three or more risers
  • Sized and shaped so your hand can encircle them
  • Permanently and securely attached, and able to withstand a 200 pound force in any direction at any point
  • Continuous and extend for the entire flight of the stairs
  • Located between 30 and 38 inches above the leading edge of the stair treads

    A qualified person should repair, replace or install as necessary and as per standard building practices.
    2) Grounds:   - Cracks in front walk. Not structural.

    3) Grounds:   - The deck gate needs a latch installed.


    4) Grounds:   - Plumbing clean out.

    5) Exterior / Foundation / Basement:   - Several areas of spalling (brick face coming off) exists on the foundation.

    Areas should be sealed / painted to minimize damage.

    6) Exterior / Foundation / Basement:   - The basement windows have been sealed with expanding foam.

    Foam should be trimmed for cosmetic purposes.

    Basement windows are low on the ground level. The risk of water entering the windows exists.

    If ground level around the windows can be lowered, it is recommended, sloping ground away from structure.

    7) Exterior / Foundation / Basement:   - Front porch trim needs to be added.

    8) Exterior / Foundation / Basement:   - Front porch screen trim has come off and needs to be reinstalled

    9) Exterior / Foundation / Basement:   - Window metal trim has come loose. Recommend re caulking and securing.

    10) Exterior / Foundation / Basement:   - The phone line on the exterior needs to be secured to the side of the structure.

    11) Exterior / Foundation / Basement:   - The front door has a started paint job that should be finished, and the door did not have a lock.

    Recommend adding a lock.

    12) Exterior / Foundation / Basement:   - The rear basement window is next to the water bibb. If bibb leaks water may enter the window.

    Water bibb should be monitored to be shut off and not leaking.

    13) Exterior / Foundation / Basement:   - Sump Pump in basement

    14) Roof / Attic: - Flashings at the base of one or more chimneys were substandard. Leaks may occur as a result.

    Inspector could see light coming through flashing from the attic.

    A qualified contractor should evaluate and repair as necessary.

    15) Roof / Attic:   - The roof next to the rear dormer shows damage to the shingles where walking on the shingles caused surface damage.

    No leaking was found.

    16) Roof / Attic:   - No gutters were installed.

    Recommend having them installed, and water directed away from the structure.

    17) Roof / Attic:   - Attic View - Blown In insulation. Bathroom vent through roof.

    18) 2 1/2 Car Garage:   - The Car Garage door opened with the hand held opener.

    When inspector tried the lights and to close the door, the power had been shut off.

    Inspector checked the circuit breaker, and it had been tripped. The inspector tried to reset the garage circuit breaker, but it would trip.

    Inspector turned the circuit breaker off. Wrote a note detailing the condition to the home owner, leaving it on the hand unit for the garage door opener in the kitchen. He the manually closed the auto garage door. And shut the yard garage door, not locking it.

    See Electrical Section.

    19) 2 1/2 Car Garage:   - The garage roof is beginning to show wear, moss growth. Estimated life is 5 years or less. No current leaks.

    Moss and tree branches should be cleaned off the roof.

    Roof should not be power washed. A Zinc bar or wash can be applied to removed moss.

    20) 2 1/2 Car Garage:   - Garage floor drain cover broken.

    Recommend - Replace

    21) 2 1/2 Car Garage:   - Minor cracks, heaving and/or settlement were found in one or more sections of slab floors.

    Recommend sealing with a silicone based concrete sealer to keep water out.

    22) 2 1/2 Car Garage:   - The driveway has several cracks that should be sealed to prevent water from entering and causing more damage in the freeze / thaw weather cycle.

    23) 2 1/2 Car Garage:   - A vinyl siding second on the front of the garage has moved opening a gap that should be closed by repositioning the siding.

    24) 2 1/2 Car Garage:   - The garage window needs to be scraped and painted

    25) 2 1/2 Car Garage:   - Trees over hanging the garage roof should be monitored and trim if necessary.

    26) Electric:   - The Car Garage door opened with the hand held opener.

    When inspector tried the lights and to close the door, the power had been shut off.

    Inspector checked the circuit breaker, and it had been tripped. The inspector tried to reset the garage circuit breaker, but it would trip.

    Inspector turned the circuit breaker off. Wrote a note detailing the condition to the home owner, leaving it on the hand unit for the garage door opener in the kitchen. He then manually closed the auto garage door. And shut the yard garage door, not locking it.

    27) Electric:   - Covers on junction boxes need to be installed.

    28) Electric:   - A double tap (two wires connected to one circuit breaker) is in the main electric service panel.

    This is a hazard due to the possibility of causing a spark.

    A qualified electrical contractor should evaluate and repair.

    29) Electric:   - This property had "knob and tube" wiring, which was commonly installed prior to 1950. It is ungrounded, and considered unsafe by today's standards. Over time, the wire's insulation may become brittle and fall apart or wear thin, resulting in exposed conductors and a risk of shock and/or fire. This wiring is also easily damaged by covering it with insulation (a common practice), and incorrectly tapping new wiring into it.

    The inspector did not find any energized knob and tube wiring during the inspection. However this is no indication that all the knob and tube wiring has been abandoned. It is not within the scope of this inspection to determine what percentage of this property's wiring is of the knob and tube type, or to determine what percentage of the knob and tube wiring is energized vs. abandoned. A qualified electrician should evaluate this wiring and make repairs or replace wiring as necessary.

    Note that some insurance companies may be unwilling to offer homeowner's insurance for properties with knob and tube wiring. Recommend that the client(s) consult with their insurance carrier regarding this.

    30) Electric:   - Main electric meter

    31) Electric:   - 100 amp main service equipment panel

    32) Plumbing / Fuel Systems:   - Main water meter in Basement. Main Gas Meter and shut off on exterior.

    33) Water Heater:   - No drain line was installed for the temperature-pressure relief valve. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. A qualified plumber should install a drain line as per standard building practices. For example, extending to 6 inches from the floor, or routed so as to drain outside.

    34) Water Heater: - Significant corrosion was found at the supply pipes or fittings. A qualified plumber should evaluate and repair or replace as necessary.

    35) Water Heater:   - The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be near this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.

    36) Heating:   - The boiler's pressure relief valve was substandard. This may pose a safety hazard. A qualified contractor should evaluate and repair as necessary. Missing drain piping

    37) Heating:   - The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.

    38) Heating:   - Dunkirk Boiler

    39) Kitchen:   - Tilt brackets were not installed behind the stove.

    Recommend having them installed.

    41) Interior Rooms / Areas:   - Guardrails in one or more areas were loose. This is a safety hazard. A qualified person should repair or replace as necessary, and as per standard building practices.

    42) Interior Rooms / Areas:   - Rear 2nd floor room has Styrofoam insulation on the walls and ceiling. Paint is peeling and cracking.

    Recommend installing drywall.


    43) Interior Rooms / Areas:   - Some interior doors were sticking. A qualified person should evaluate and repair as necessary.

    44) Interior Rooms / Areas:   - Inspector recommends adding door stops to prevent wall damage.

    45) Interior Rooms / Areas:   - The porch storm door latch is loose and needs to be tightened.

    46) Interior Rooms / Areas:   - Not heat in Bedroom

    47) Interior Rooms / Areas:   - No closet in Bedroom