BEBE'S HOME INSPECTION

Website: http://www.reporthost.com/bebeshi
Email: johnnyn1971@yahoo.com
Phone: (843) 367-8448 · (843) 406-2877
1324 TRENHOLM DR CHARLESTON SC 29412

  

BEBE'S HOME INSPECTION
1324 TRENHOLM DR CHARLESTON
Client(s): Joe Smith
Property address: 10 CLEARWATER DR
GOOSE CREEK,S.C
Inspection date: Saturday, March 01, 2008
This report published on 3/27/2008 8:28:07 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Crawl space
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 014
Structures inspected: 1
Type of building: Single family
Age of building: 30 YEARS
Property owner's name: NA
Time started: 1:00
Time finished: 3:45
Inspection Fee: $250.00
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Front of structure faces: East
Main entrance faces: East
Foundation type: Crawlspace
The following items are excluded from this inspection: Central vacuum system
Report number: 014
Structures inspected: 1
Type of building: Single family
Age of building: 30 YEARS
Property owner's name: NA
Time started: 1:00
Time finished: 3:45
Inspection Fee: $250.00
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Front of structure faces: East
Main entrance faces: East
Foundation type: Crawlspace
The following items are excluded from this inspection: Central vacuum system
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Concrete block
Apparent wall structure: Wood frame
Wall covering: Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel


1)   One or more sets of stairs are wobbly. A qualified contractor should evaluate and repair as necessary, such as installing additional supports and/or diagonal bracing.

Photo 7  

2)   Minor cracks were found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.

Photo 9  

3)   Soffit boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 14  

4)   One or more crawl space vent screens are missing. Animals such as vermin or pets may enter the crawl space and nest, die and/or leave feces and urine. A qualified contractor should install screens where missing using screen material such as "hardware cloth" with 1/4 inch minimum gaps.

Photo 6  

5)   One or more exhaust duct end caps are damaged and/or deteriorated. Their purpose is to prevent unconditioned air from entering the house, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and may pose a fire hazard. New vent cap(s) should be installed where necessary.

Photo 8  

6) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.

Photo 5  

7)   Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 13  

8)   Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 3  

Photo 4  

9)     DOOR ON BACK DECK ROTTED AT BOTTOM

Photo 10  

10)     WOOD ROTTED ON RIGHT SIDE OF GARAGE WATER MAYBE POOLING THERE AND RUNNING INTO GARAGE.

Photo 12  
 
Roof Return to table of contents
Roof inspection method: Traversed
Roof type: Hipped
Roof covering: Asphalt or fiberglass composition shingles
Gutter & downspout material: None
Roof ventilation: Adequate
11) One or more sections of flashing at the base of the chimney are deteriorated and/or substandard. Leaks may occur as a result. A qualified roofing contractor should evaluate and repair as necessary.

Photo 37  

12) One or more "rubber boot" flashings are damaged or deteriorated and may result in leaks or vermin intrusion. A qualified contractor should replace flashings where necessary.

Photo 36  

13)   THIS SPOT IS ABOVE THE BEDROOM IN FRONT AND MAY LECK

Photo 35  
 
Garage Return to table of contents

14)   Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

Photo 24  

15)     WALL ON RIGHT SIDE HAS WATER DAMAGE

Photo 30  

Photo 31  

16)     DOOR GOING TO THE BACK YARD IS BLOCKED

Photo 29  

17)     CEILING HAS PAINT PEELED OFF

Photo 32  
 
Attic Return to table of contents
Inspection method: Traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass loose fill
Insulation depth: 5 INCHES
Insulation estimated R value: R-13
18)   Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

Photo 33  

19)     THIS IS YOUR DOORBELL

Photo 34  
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: IN GARAGE
Location of main disconnect: Top bank of breakers in main service panel (split bus)
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil
Main disconnect rating (amps): Not applicable, no single main disconnect
Branch circuit wiring type: Copper, Aluminum multi-strand
Solid strand aluminum branch circuit wiring present: Yes
Smoke detectors present: Yes
20)   One or more overcurrent protection devices (circuit breakers or fuses) are "double tapped", where 2 or more wires are clamped in a terminal designed for only one wire. This is a safety hazard since the bolt or screw may tighten securely against one wire, but leave others loose. Arcing, sparks and fires may result. A qualified electrician should evaluate and repair as necessary.

Photo 27  

21)     ALUMINUM WIRE RUNS TO HEAT PUMP

Photo 28  

22)     PANEL IS A GE AND NOT WELL MARKED

Photo 26  
 
Water heater Return to table of contents
Estimated age: 13 YEARS
Type: Tank
Energy source: Electricity
Capacity (in gallons): 50
Manufacturer: A.O. Smith
Model: EES-52-917
Water temperature (degrees Fahrenheit): NA
23) Corrosion was found in one or more areas on the water heater. The water heater may be failing. A qualified plumbing contractor should evaluate and replace or repair water heater if necessary.

Photo 25  

24)   The water heater was turned off at the time of the inspection. For example, circuit breaker turned off, gas supply turned off or pilot light turned off. The inspector was unable to fully evaluate the water heater.
 
Heating and cooling Return to table of contents
Estimated age: 13 YEARS
Primary heating system energy source: Electric
Primary heat system type: Heat pump
Primary A/C energy source: Electric
Primary Air conditioning type: Heat pump
Manufacturer: Heil
Model: PHRA36N1K2
Filter location: Behind return air grill
Last service date: NA
25)   Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 80 PSI
Location of main water shut-off valve: NONE
Location of main water meter: FRONT YARD
Location of main fuel shut-off: NA
Visible fuel storage systems: NA
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
26) One or more active leaks were found in drain and/or waste pipes or fittings. A qualified plumber should evaluate and repair as necessary.

Photo 38  

27) No clothes dryer exhaust duct is installed. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
 
Fireplaces, woodstoves and chimneys Return to table of contents
Fireplace type: Masonry with metal liner
Chimney type: Masonry
28)   The damper in one or more fireplaces is stuck and cannot be opened or closed. A qualified chimney service contractor should evaluate and make repairs as necessary.
 
Crawl space Return to table of contents
Inspection method: Traversed
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: Concrete
Beam material: Solid wood
Floor structure above: Solid wood joists
29)   Evidence of "light to moderate" rodent infestation was found in one or more areas. The Center for Disease Control (CDC) defines this as less than 20 feces per square foot. Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.

Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hantavirus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The client(s) may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygienist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).

30) The vapor barrier is in poor condition. For example, installed in a substandard way, large areas of exposed soil, cuts or tears in the plastic, significant amounts of sediment on top, etc. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified contractor should replace the vapor barrier. Standard building practices require the following:

  • The soil below the vapor barrier should be smooth and free from sharp objects.
  • Seams should overlap a minimum of 12 inches.
  • The vapor barrier should lap up onto the foundation side walls.

    Better building practices require that:

  • Seams and protrusions should be sealed with a pressure sensitive tape.
  • The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.
    31)   Some crawl space areas were inaccessible due to low height (less than 18 inches), ductwork or pipes blocking, standing water, and/or stored items. These areas are excluded from this inspection.
    32)     TERMITE DAMAGE ON ABOUT 10 FLOOR JOISTS

    Photo 39  
     
    Kitchen Return to table of contents

    33) Tile, stone and/or grout flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary. For example, replacing broken tiles and deteriorated grout, and resealing grout.

    Photo 23  

    34)   One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
     
    Bathrooms Return to table of contents

    35) Caulk is missing and/or deteriorated at one or more showers. For example, where the shower base meets the floor below and/or around the shower surround. Caulk should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall and floor structures.

    Photo 21  

    36) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

    Photo 20  
     
    Interior rooms Return to table of contents

    37)   One or more electric receptacles have burn or scorch marks on them. Receptacle(s) and/or wiring to them may be damaged. A qualified electrician should evaluate and make repairs as necessary, such as replacing damaged receptacles and/or wiring.

    Photo 19  

    38) Stains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary.

    Photo 18  

    39) Tile, stone and/or grout flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary. For example, replacing broken tiles and deteriorated grout, and resealing grout.

    Photo 15  

    40)   Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

    Photo 16  
     

    Photo 11  
    OUTLET WAS MOVED BUT NEEDS TO BE COVERED

    Photo 17  
    THE BOTTOM OF THE HOSE IS RUSTED MAY NEED TO CHANGE

    Photo 22  
    THIS IS DAMAGE FROM THE ROOF LECKING AROUND THE CHIMNEY

     
    THANK YOU FOR YOUR TIME