Property Inspection Report
Client(s): MATT HALLMAN
Property address: 3904 EDITH DR.
ALBANY, GA
Inspection date: Friday, January 29, 2010
This report published on 1/30/2010 7:51:03 PM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 10-1005
Inspector: DM
Age of building: 12
Time started: 1230
Time finished: 1500
Inspection Fee: 225.00
Payment method: Check 365
Present during inspection: Client(s)
Occupied: No
Weather conditions: Clear
Temperature: Cool
Ground condition: Damp
Foundation type: RAISED FOUNDATION
 
Exterior Return to table of contents
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
1) Repair/Replace, Evaluate - Fences and/or gates are damaged and/or deteriorated in some areas
2) Repair/Maintain - One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
    3) Repair/Maintain - Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

    Photo 2  
    TRIM BACK
     

    4) Monitor, Comment - SOME WOOD ROTEN ON POUCH, POSTS AND GARAGE DOOR. TILES CRACKED ON BACK POUCH.

    Photo 3  
    WATER DAMAGE

    Photo 7  
    WOOD MISSING / ROTTEN

    Photo 15  
    BACK POUCH TILES CRACKED

    Photo 16  
    BACK POUCH TILES CRACKED

    Photo 17  
    ROTTEN WOOD
     

    5) Comment - Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
    6) Comment - SOME OF THE SPRINKLER SYSYEM WAS NOT WORKING, COULD NOT FIND ANY TIMER.

    Photo 4  
    SPRINKLER SYSTEM
     
     
    Roof Return to table of contents
    Roof inspection method: Viewed from ground with binoculars
    Roof type: Cross-hipped
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 12
    Roof ventilation: Adequate
    7) Repair/Replace, Evaluate - One or more sections of metal roofing are dented and/or damaged. A qualified roofing contractor should evaluate and replace sections and/or make repairs as necessary.

    Photo 5  
    ROOF DENTED
     

    8) Maintain - Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
    9) - SOME OF THE VENT BOOTS IN NEED OF REPAIRING

    Photo 34  
    NEED TO SEAL
     
     
    Garage Return to table of contents

    10) - SOME HOLES IN WALLS ON THE BACKSIDE OF WASHING AND DRYER.

    Photo 9  
    HOLE IN WALL IN GARAGE
     
     
    Attic Return to table of contents
    Inspection method: Traversed
    Roof structure type: Trusses
    Ceiling structure: Trusses
    Insulation material: Mineral wool loose fill
     
    Electric service Return to table of contents
    Primary service type: Underground
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 200
    Service voltage (volts): 120/240
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Aluminum
    System ground: Ground rod(s) in soil
    Main disconnect rating (amps): 200
    Branch circuit wiring type: Non-metallic sheathed
    Smoke detectors present: Yes
     
    Water heater Return to table of contents
    Estimated age: 12
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 66
    Manufacturer: A.O. Smith
    11) Major Defect, Comment - The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    12) Repair/Replace, Serviceable, Comment - The water heater is installed in an unheated space. Recommend installing an insulated pad around the water heater for better energy efficiency.

    Photo 8  
    WATER HEATER NAME PLATE
     
     
    Heating and cooling Return to table of contents
    Estimated age: 12
    Primary heating system energy source: Electric
    Primary heat system type: Heat pump
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system, Heat pump
    Distribution system: Flexible ducts, Metal pipe
    Manufacturer: Rheem
    Filter location: Behind return air grill
    Last service date: UNK
    13) Repair/Maintain, Evaluate - The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.

    Photo 6  
    A/C NAME PLATE

    Photo 12  
    DIRTY FILTER

    14) Maintain - Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.

    Photo 29  
    AIR HANDLER IN ATTIC

    Photo 30  
    AIR HANDLER NAME PLATE
     
    Plumbing and laundry Return to table of contents
    Water pressure (psi): ADQ
    Location of main fuel shut-off: FRONT
    Water service: Public
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    15) Repair/Replace - No clothes dryer exhaust duct is installed. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
     
    Kitchen Return to table of contents

    16) Safety, Repair/Replace, Evaluate, Serviceable, Comment - Substandard wiring was found for the under-sink food disposal. Unprotected solid-strand, non-metallic sheathed (Romex) wiring is used. The insulation can be damaged by objects coming in contact with it and/or it being repeatedly moved. This is a safety hazard due to the risk of shock and fire. Armored (BX) cable, or a flexible appliance cord with a plug end and electric outlet should be used. A qualified electrician should evaluate and repair as necessary.

    Photo 10  
    WIRES EXPOSED
     

    17) Repair/Replace, Minor Defect, Evaluate, Serviceable, Comment - One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary. Some of the fixtures missing in some rooms.

    Photo 18  
    MISSING LIGHT FIXTURE
     

    18) Repair/Replace, Comment - MICROWAVE NOT IN WORKING ORDER.

    Photo 33  
    BAD MICRO WAVE
     

    19) Repair/Maintain - Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

    Photo 11  
    NEEDS CAULKING
     
     
    Bathrooms Return to table of contents

    20) Safety, Repair/Replace, Evaluate - One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.

    Photo 24  
    GFCI NOT WORKING IN HALL BATH

    Photo 25  
    GFCI NOT WORKING IN HALL BATH

    21) Safety, Minor Defect - Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    Photo 20  
    NEEDS COVER UNDER JET TUB

    Photo 21  
    NEEDS COVER UNDER JET TUB

    Photo 23  
    COVER MISSING
     

    22) Safety, Serviceable, Comment - UNDER JET TUB THERE IS A AREA THAT YOU CAN SEE EARTH, SUGGEST FILLING WITH FORM OR SOME MATERIAL THAT WILL NOT LET AIR IN.

    Photo 22  
    FULL IN HOLE UNDER TUB
     

    23) Repair/Maintain - Caulk is missing and/or deteriorated at one or more bathtubs. For example, where the tub base meets the floor below, where the tub surround meets the tub, and/or around the base of the tub spout. Caulk should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall and floor structures.
     
    Interior rooms Return to table of contents

    24) Safety, Minor Defect - Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    25) Safety, Maintain - Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    26) Comment - Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

    Photo 13  
    CEILING CRACK

    Photo 14  
    CEILING CRACK
     

    Photo 19  
    NAIL COMING OUT IN CEILING

    Photo 26  
    ATTIC

    Photo 27  
    ATTIC

    Photo 28  
    ATTIC

    Photo 31  
    MANA BLOCK WATER SYSTEM

    Photo 32  
    ELECTRICAL PANEL

    Photo 35  
    NOT LEAKING
     

     
    Done By Don Mazza / A-Z Home Inspections