How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 050308-2
Structures inspected: Single Family 2 Story
Type of building: Single family
Time started: 03:45
Time finished: 5:15
Inspection Fee: 140
Occupied: No
Weather conditions: Clear
Temperature: Warm
Front of structure faces: South
Foundation type: Slab on grade
The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stone veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
2) One or more trip hazards were found in sidewalk and/or patio sections due to protrusion of CB type straps.

Photo 10  
"CB" type straps sitting up in concrete. Tripping hazard
 

3) Sidewalks and/or patios have void in area against rear of home A qualified contractor should evaluate and repair or replace sidewalk and/or patio sections as necessary.

Photo 11  
void in concrete area in rear of home.
 

4) One or more crawl space vent screens are missing. Animals such as vermin or pets may enter the crawl space and nest, die and/or leave feces and urine. A qualified contractor should install screens where missing using screen material such as "hardware cloth" with 1/4 inch minimum gaps.
5) Minor cracks in stucco noted.

Photo 15  
Minor cracks in stucco. Cosmetic
 

6) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.
7) The exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.
8) Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 4  
Minor Cracks in Drive/Walkway areas
 
 
Roof Return to table of contents
Roof inspection method: Traversed
Roof covering: Concrete tile
Roof ventilation: Adequate
9) One or more roofing tiles are chipped and/or cracked. A qualified roofing contractor should evaluate and replace tiles as necessary.

Photo 2  
Slipped / Broken Tiles around roof flashing
 

10) One or more roofing tiles have slipped, and are loose. A qualified roofing contractor should evaluate and repair as necessary.

Photo 3  
Slipped tiles
 
 
Garage Return to table of contents

11) Garage Door opener has excessive slack in chain. Suggest having qualified contractor service.

Photo 22  
Excessive slack in drive chain for garage door opener. Recommend having unit serviced by qualified contractor.
 

12) The weatherstrip around one or more exterior entry doors is missing and/or deteriorated. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.

Photo 23  
Weatherstripping missing from garage exterior door
 
 
Attic Return to table of contents
Inspection method: Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Cellulose loose fill
Insulation depth: 6"
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service voltage (volts): 120/240
Location of main service switch: South / East Corner of Home
Location of main disconnect: Top bank of breakers in main service panel (split bus)
System ground: Ground rod(s) in soil, Cold water supply pipes
Branch circuit wiring type: Non-metallic sheathed, Copper
Solid strand aluminum branch circuit wiring present: Can't verify
Smoke detectors present: YesSome missing in home
13) Neutral wires are doubled or bundled together on the neutral bus bar. This is unsafe due to the need to turn off multiple circuit breakers to work on any of the circuits using these wires. A qualified electrician should evaluate and repair as necessary.

Photo 46  
Double tap connections exist in main panel. Suggest having qualified electrical contractor evaluate.
 

14) Low voltage interior lighting was found during the inspection. This is considered to be a specialty system. Only a cursory evaluation of this lighting was performed during the inspection. For a full evaluation, the client(s) should hire a qualified electrician.
 
Water heater Return to table of contents
Energy source: Natural gas
Capacity (in gallons): 50
15) The water heater was turned off at the time of the inspection. For example, circuit breaker turned off, gas supply turned off or pilot light turned off. The inspector was unable to fully evaluate the water heater.

Unit does not turn on at this time. Inspector attempted to light pilot to confirm operation. As noted this unit has missing control wires. Should have qualified plumbing contractor to evaluate for repair or replacement.

Photo 19  
Cut drain from original instalation for Tempurature and Pressure relief valve. Unsure of why this was not installed to water heater T&P system on replacement unit. Possible Amateur installation

Photo 20  

Photo 21  
Control Line disconected from water heater control unit. unit does NOT operate. Not able to test.
 
 
Heating and cooling Return to table of contents
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Distribution system: Sheet metal ducts, Flexible ducts
Filter location: In return air duct above furnace
Last service date: unknown, suggest service
16) As noted, flex duct has damage to vapor barrier. Suggest having qualified contractor repair.

Photo 45  
Flex duct has damage to vapor barrier.
 

17) The cooling fins on the outdoor condensing unit's evaporator coils are bent, damaged and/or deteriorated. This may result in reduced efficiency and higher energy costs. A qualified heating and cooling contractor should evaluate and repair as necessary.

Photo 8  
condensor coils showing signs of corrosion. Recommend service
 

18) Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.

Photo 9  
Insulation missing from copper lines to external compressor / condensor unit
 

19) Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 59 psi
Location of main water shut-off valve: Curb
Location of main water meter: Curb
Location of main fuel shut-off: South East Corner
Visible fuel storage systems: no
Water service: Public
Service pipe material: Copper
Supply pipe material: Sch 40 PVC
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
20) Stains were found in one or more sections of drain and/or waste pipes. Recommend monitoring these areas in the future, and if leaks are found, have a qualified plumber evaluate and repair as necessary. Alternatively, the client(s) may wish to have a qualified plumber evaluate now and repair if necessary.

Photo 32  
evidence of corrosion at washer hookups in laundry area.
 
 
Fireplaces, woodstoves and chimneys Return to table of contents
Fireplace type: Metal prefabricated
Chimney type: Metal
21) Significant amounts of ashes, wood and/or debris are in the fireplace. The inspector was unable to fully evaluate it.

Gas Log in place with vermiculite. Did not see any cracks in refractory plates.

22)   Fireplace door handles damaged.

Photo 41  
Broken handle for fireplace
 
 
Kitchen Return to table of contents

23) The dishwasher is excessively noisy. A qualified appliance technician should evaluate and repair as necessary, or the dishwasher should be replaced.

Photo 39  
Dishwasher has noisy operation. May be near end of serviceable life.
 

24) One or more faucets leak by handle(s) or at their base when turned on. A qualified plumber should evaluate and repair as necessary.
25) Drawers are difficult to open and close in one or more cabinets. A qualified contractor should evaluate and repair as necessary.

Photo 43  
Loose / mis-aligned hardware present on cabinets such as this drawer
 

26) Hardware such as hinges, latches or pulls are loose and/or missing on one or more cabinets. Repairs should be made and/or hardware should be replaced as necessary, and by a qualified contractor if necessary.

Photo 42  
Cabinets slightly weathered. Missing cutting board as well.
 

27) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

Photo 44  
Grout / sealant missing in wet areas Kitchen
 

28) One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.

Also note photo oven/range

Photo 38  
Stove controls / knobs damaged / broken Kitchen
 

29) Water stains and/or minor water damage was found in the shelving or cabinet components below the sink. The client(s) should evaluate and consider having repairs made.

Photo 6  
evidence of current/prior leak under kitchen sink
 
 
Bathrooms Return to table of contents

30) Vanity mirror broken master bedroom

Photo 27  
Broken Vanity in Master Bathroom
 

31) One or more sink drains have an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified plumber should evaluate and repair as necessary.

Photo 18  
current / prior leak under bathroom sink
 

32) One or more toilets appear to be clogged, and/or do not flush adequately. A qualified plumber should evaluate and make repairs or replace toilet(s) as necessary.

Photo 5  
Master toilet clogged with debris
 

33) One or more faucet handles are loose or missing and should be repaired or replaced as necessary.

Photo 17  
trim loose to bathroom shower controls
 
 
Interior rooms Return to table of contents

34) One or more smoke alarms are damaged, deteriorated and/or missing from their mounting brackets. Damaged and/or missing smoke alarms should be replaced as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html

Photo 24  
smoke detector missing

Photo 26  
missing smoke detector

35) One or more electric receptacles/switches are broken or damaged. This is a safety hazard due to the risk of fire and shock. A qualified electrician should replace them as necessary.

Photo 29  
Damaged electrical switch / adjacent to stairway area

Photo 31  
Damaged electrical switch

36) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.

Photo 33  
unfinished opening in downstairs bedroom for Cable TV line. Suggest having line secured on backside of wall and line brought through proper wall plate

Photo 47  
Broken outlet covers present in home such as this one.

37) One or more electric receptacles appear to have no power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Photo 40  
Outlet in Livingroom not functioning properly. Inspector was not able to find switch location to control this outlet. Suggest having qualified contractor verify operation.
 

38) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
39) Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.

Photo 12  
Several Broken windows

Photo 13  
another example of broken windows

40) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.

Photo 28  
Broken interior door / Master Bedroom
 

41) Exterior door to rear / patio area damaged at jamb and trim

Photo 16  
jamb / trim damaged to exterior rear door
 

42) Various interior cabinets in need of service

Photo 34  
Various cabinets have shelf paper lifting thru out . In need of cleaning as well.
 

43) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.

Photo 30  
various stains on carpet
 
 

Photo 7  
Pool too low to test, unkept condition

Photo 14  
unfinished wood / trim around exterior door

Photo 25  
evidence of possible current/prior leak / upstairs bathroom

Photo 35  
Fan / lite fixture missing cover for bulb.

Photo 36  
Mismatched closet/wardrobe doors / downstairs bedroom.

Photo 37  
Window treatments damaged / falling apart in various areas

 
Please call if there are any questions, comment or concerns.