A.F.A. HOME INSPECTIONS LLC

Website: http://www.reporthost.com/amiccuci
Email: tonyamicc@hotmail.com
Phone: (518) 588-9693 · (518) 374-5638
1336 TRACY SCHENECTADY 
NY, 12309 

 

Property Inspection Report
Client(s): William McClune DC PC
Property address: 10 Forts Ferry Road
Inspection date: Wednesday, July 09, 2008
This report published on 7/11/2008 10:58:14 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Basement
Kitchen Basement
Bathroom Basement
Interior rooms
Shed
Bathroom (main)
 
General information Return to table of contents
Structures inspected: HOME, GARAGE AND SHED
Time started: 9.30 AM
Time finished: 12.20 PM
Present during inspection: Client(s), Realtor(s)
Occupied: No, but furnishings and stored items are present
Weather conditions: Clear
Temperature: APPROX 80 DEGREES
Ground condition: Dry
The following items are excluded from this inspection: Security system, Irrigation system, Water filtration system, Water softener system


1) Carbon monoxide detectors should be placed in the basement near the boiler unit as well as on the main floor near the fireplace.
2) Client is aware that there is a oil tank buried on the property and is awaiting results of enviromental testing.
 
Exterior Return to table of contents
Footing material: Not visible
Foundation material: Concrete block
Wall structure: Brick
Driveway material: Asphalt
3) Handrail(s) at the front and rear entrance stairs are loose or rusted.This is a safety hazard. A qualified contractor should make repairs as necessary.

Photo 2  
 

4) Minor cracks and/or deterioration were found in the brick on the right front and right rear corner.. Recommend repairing cracks to prevent water intrusion and further deterioration. The client(s) should monitor such walls in the future for continued deterioration (cracking, leaning, bowing, etc.). Repairs and/or replacement by a qualified contractor may be necessary in the future.

Photo 11  
 

5) A small piece of brick has broken off a section of basement window trim. Client should consider having a qualified contractor repair.

Photo 3  
 

6) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

Photo 7  
 

7) Garbage shed floor has a minor crack that should be repaired by a qualified contractor.

Photo 9  
 

8) Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 15  
 

9)   Window wells should be cleaned out and covered.

Photo 1  
 

10)   At the base of trees there are approx 14" deep wells. These need to be filled in to prevent injurys from occuring.

Photo 5  
 
 
Roof Return to table of contents

11) One or more composition shingles are damaged, deteriorated and/or missing, and should be replaced. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary.

Photo 4  
 

12) To compensate for mismatch of structure shim shingles were placed under the roof decking.

Photo 16  
 

13) Buckeled shingles on the roof may be a result of poor ventilation in the soffits. Recommend clearing soffit area in attic to allow for proper ventilation. Client may want to begin budgeting for a new roof in the future.

 
Garage Return to table of contents

14) No infrared "photo eye" devices are installed for the vehicle door's electric door opener. They've been required on all vehicle door openers since 1993 and improve safety by triggering the vehicle door's auto-reverse feature without need for the door to come in contact with the object, person or animal that's preventing it from closing. Recommend considering having a qualified contractor install these devices for improved safety. For more information on garage door safety issues, visit: http://www.cpsc.gov/cpscpub/pubs/523.html or http://www.ohdstl.com/safety.html
 
Attic Return to table of contents
Inspection method: Traversed
Roof structure type: Rafters
Insulation material: Fiberglass roll or batt
15) One or more attic vents are blocked by insulation and/or debris. This can reduce air flow through the attic, reduce the life of the roof surface because of high temperatures, and/or increase moisture levels in the attic. Repairs should be made as necessary, such as moving insulation or debris, so vents are unobstructed.
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Basement
Location of sub panels: One in garage as well as one in shed.
Service entrance conductor material: Aluminum
System ground: Cold water supply pipes
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed, (BX) Armor clad
Smoke detectors present: Yes
16) In main electrical panel there is one double tapped breaker. This is a safety hazzard and needs to be evaluated and repaired by a qualified contractor.
17) Main electrical panel should have a legend to inform client as to which breaker is for what items.
 
Water heater Return to table of contents
Energy source: Electricity
Manufacturer: A.O. Smith
 
Heating and cooling Return to table of contents
Primary heating system energy source: Oil
Primary heat system type: Baseboard hot water
Primary A/C energy source: Electric
Manufacturer: Crane for boiler unit
Model: #70-122
Filter location: 1st floor ceiling outside bathroom.
18) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
19) This boiler appears to be at the end of its usefull life expectancy and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 14  
 

20) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceeded this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
21) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
22) One of the fan motors on the condensing unit did not operate . Unit could not be evaluated. A qualified contractor should evaluate and repair.
23) Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.
24)   Boiler could not be operated due to interior temperature in the house exceeded 80 degrees. Recommend that the client has unit serviced and evaluated by a qualified heating contractor due to age of unit.
 
Plumbing and laundry Return to table of contents
Location of main water shut-off valve: Basement
Location of main water meter: Basement
Location of main fuel shut-off:
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
25) Copper water supply pipes in homes built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained about 50 percent lead. The client(s) should be aware of this, especially if children will be living in this structure. Evaluating for the presence of lead in this structure is not included in this inspection. The client(s) should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions such as these may be advised:

  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than six hours.
  • Install appropriate filters at points of use.
  • Use only cold water for cooking and drinking. Hot water dissolves lead more quickly than cold water.
  • Use bottled or distilled water.
  • Treat well water to make it less corrosive.
  • Have a qualified plumbing contractor replace supply pipes and/or plumbing components as necessary.

    For more information visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5056.html
    http://www.epa.gov/safewater/lead/index.html
    26) A sump pump is installed on the premises. This may indicate that water accumulates inside or below the structure. Recommend asking the property owners how often the sump pump operates and for how long at different times of the year. Also, the clients should be aware that the service life of most sump pumps is between five and seven years, and that the pump may need replacing soon depending on its age and how much it operates. Pump needs to be secured to prevent tipping.
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Fireplace type: Masonry
    Chimney type: Masonry
    27) All fireplaces should be inspected annually by a CSIA for a NFPA level 2 chimney inspection.
     
    Basement Return to table of contents
    Beam material: Solid wood
    28) Client should consider updating electrical outlets in the basement with GFCI protected outlets.
    29) The 220 volt pigtail in basement needs to be secured to the wall.This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary.

    Photo 10  
     

    30) Minor cracks in basement floor need to be repaired and monitored in the future.
     
    Kitchen Basement Return to table of contents

    31) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 12  
     
     
    Bathroom Basement Return to table of contents

    32) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    33) One or more toilets are loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.
    34) Evidence of water damage on ceiling tile in bathroom. Evaluate and have repaired by a qualified contractor if necessary.

    Photo 13  
     

    35) Exhaust fan is not vented outside. This could create a moisture problem.
    Have a qualified contractor evaluate and make necessary repairs.
     
    Interior rooms Return to table of contents

    36) One or more open ground, two pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
    37) In the previous kitchen area there are water shut off valves that should be capped.
    38) Batteries in all the smoke alarms should be replaced after taking occupancy, and bi-annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    39) Sink located in exam room 1 had no hot water. Sink in exam room 2 had no water. Have a qualified contractor evaluate and repair.
     
    Shed Return to table of contents

    40)   Wood that is stored in the shed should be removed to prevent infestation.

    Photo 8  
     
     
    Bathroom (main) Return to table of contents
    Toilet: One or more toilets are loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.
    41) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    42) Bathtub is being used for storage. Plumbing could not be inspected.

    Photo 17