Home Inspection Report
Client(s): Laura Toney
Property address: 560 Bernasek Dr
Debary, Fl. 32713
Inspection date: 11/9/2010
This report published on Wednesday, November 10, 2010 7:18:31 PM EST

View summary page

This report is the exclusive property of All Over Home Inspections and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Structures inspected: Home
Type of building: Single family
Age of building: 25 Years
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
Foundation type: Slab on grade
The following items are excluded from this inspection: Private sewage disposal system, Irrigation system, Swimming pool, Central vacuum system
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Cedar Siding
Driveway material: Poured in place concrete
1) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior. There is a large hole in the siding where the water line exits the rear of the home. this should be sealed to prevent insects and rodents from entering the home. Two plants have roots growing into the siding on the rear of the home. these roots should be removed to prevent the siding from splitting or being loosened.

Photo 5  
vegetation growing against home.

Photo 7  
Plant root growing into siding at rear of home.

Photo 8  
Vegetation growing against home.

Photo 6  
Hose bib at rear of the home needs siding sealed.
Plant root growing into siding below hose bib needs to be removed.

2) Small isolated areas of wood rot was observed on the siding. I recommend having the rotted areas replaced and the exterior of the home repainted.

Photo 2  
Wood rot on siding at garage door

Photo 3  
wood rot

Photo 4  
Wood rot on siding
 
 
Roof Return to table of contents
Roof inspection method: Traversed
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Roof ventilation: Adequate
3) Roofing nails in one or more areas have loosened or backed out. Leaks may occur as a result. A qualified roofing contractor should evaluate the entire roof and make repairs as necessary, such as reseating nails and applying sealant.

Photo 1  
Nail pops on roof.
 
 
Garage Return to table of contents

4) The overhead garage door does not have the auto reverse installed properly. As a result the door will continue to close even if something is in its path.
 
Attic Return to table of contents
Inspection method: Traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass loose fill
5) The attic of this home is very large. Insulation is on average 6 inches deep. The ridge vent and soffit vents were found to be unobstructed.
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Panel next to meter base.
Location of sub panels: Garage
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
6) All outlets were checked and found to be in working order. Some of the outlets in the home are missing covers. These outlets should have the covers replaced. No open grounds or reverse polarity was found.
 
Water heater Return to table of contents
Estimated age: new
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
Manufacturer: Whirlpool
7) This is a new water heater and should have many years of useful life.
 
Heating and cooling Return to table of contents
Primary heating system energy source: Electric
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Heat pump
Distribution system: Sheet metal ducts, Flexible ducts
Manufacturer: American Standard
Filter location: At the base of the furnace
8) The AC and Furnace of this home appear to have been replaced. The AC was run and a differential of 15 degrees was found. These units should have many years of service left. However, regular maintenance should be preformed to maximize their life.
 
Plumbing and laundry Return to table of contents
Water service: Public
Service pipe material: Galvanized steel
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
9) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
10) All sinks tubs and toilets were tested and found to be free of leaks. Water pressure throughout the home was good and drainage was adequate.
 
Kitchen Return to table of contents

11) One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
 
Bathrooms Return to table of contents

12) The light in the hall bath needs new bulbs. All tubs, showers, sinks and toilets were operating at the time of the inspection. No leaks were found under the bathroom vanities.
 
Interior rooms Return to table of contents

13) The interior of the home is in very good condition for a home of this age. Only minor cosmetic damage was observed. some light bulbs in the home are burned out. Some of the light fixtures are missing globes. These bulbs and globes should be replaced.
 