Pichon071910
Client(s): Jory Pichon
Property address: 62502 Judy Street
Lacombe, La. 70445
Inspection date: 7/19/2010
This report published on Saturday, July 31, 2010 10:05:08 AM CDT

View summary page


Acutec is a proud member of InterNACHI.


This report is the exclusive property of Acutec Home Inspectors and is intended for the sole use of the client named on the report. Use of this report by any unauthorized persons is prohibited.


This report list the systems and components inspected by this company. Items not found in this report are considered beyond the scope of this inspection, and should not be considered inspected at this time. Please refer to your inspection agreement and the Standards of Practice for for details relating to the scope of the inspection or report.


Please read this entire report as there may be items, defects, concerns or safety issues that were not discussed at the time of the inspection.


 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Crawl space
Well
Kitchen
Bathrooms

 
General information Return to table of contents
Report number: 071910-1
Inspector's name: Shawn Gregg
Structures inspected: Single family resident
Type of building: Single family
Age of building: Approximately 19 years old as per property owner - Joanie Cousin.
Property owner's name: Joanie Cousin
Time started: 4:15
Time finished: 8:15
Inspection Fee: $ 300.00
Payment method: Check
Present during inspection: Client(s), Property owner(s)Termite Inspector
Occupied: No, but furnishings and stored items are present
Weather conditions: Clear
Temperature: Hot 90 Degrees
Ground condition: Dry
Front of structure faces: East
Main entrance faces: East
Foundation type: Raised pier
The following items are excluded from this inspection: Private sewage disposal system, Private well, Shed, Playground equipment, Low voltage outdoor lighting, Water filtration system, Water softener system, Outbuildings
1) Some wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items. Some areas couldn't be evaluated.
2) Some of the appliances were disconnected or removed from the house as it was vacated prior to the inspection. The items or systems were not tested. Some of the items excluded are; Water heater, Washing machine, Clothes dryer, and Refrigerator.
 
Exterior Return to table of contents
Foundation material: Post and pier on cement blocks.
Apparent wall structure: Wood frame
Wall covering: Vinyl
Driveway material: Gravel, Dirt
Exterior door material: Solid core wood
Footing material: Poured in place concrete
Sidewalk material: Poured in place concrete - Rear sidewalk
3) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.

The GFCI on the rear of the house would not trip when tested. The outlet of the front of the house was not a GFCI, but may or may not be downstream of a protected outlet. Both of these outlets should be GFCI protected.

Photo 6  
GFCI on rear not working properly

Photo 7  
Front outlet not tripping from GFCI test.

4) Guardrails are missing from one or more sections of decks or elevated surfaces with high drop-offs. This is a safety hazard due to the risk of falling. Standard building practices require guardrails to be installed at drop-offs higher than 30 inches, but in some cases it is advised to install them at shorter drop-offs. A qualified contractor should evaluate and install guardrails as necessary and as per standard building practices.

Photo 4  
Recommend installing guard rails on front porch.
 

5) One or more crawl space vent screens are missing. Animals such as vermin or pets may enter the crawl space and nest, die and/or leave feces and urine. A qualified contractor should install screens where missing using screen material such as "hardware cloth" with 1/4 inch minimum gaps.
6) Recommend cleaning deck(s) and railing(s) and treating with a preservative claiming to waterproof, block ultraviolet light, and stop mildew. Consumer Reports recommends these products:

  • Cabot Decking Stain and PTW Stain
  • Olympic Water Repellent Deck Stain
  • Thompson's House and Deck Stain
  • Wolman PTW Deck Stain
  • Akzo Sikkens Cetol DEK
  • Benjamin Moore Moorwood Clear Wood Finish
  • DAP Woodlife Premium
  • Olympic Natural Look Protector Plus
    7) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit:
    The Ins and Outs of Caulking.

    The bottom of the porch columns are begining to deteriorate and need to be caulked and painted to help avoid further damage.

    Photo 5  
    Minor water damage. Recommend caulk and paint on all exterior areas.
     

    8) Firewood is stored so that it's either in contact with the structure or very close to it. This is a conducive condition for wood destroying insects. Recommend storing firewood outdoors in an open area, as far away from the house as practical, to keep away insects. For more information, visit:
    http://www.google.com/search?q=firewood+insects

    9) One or more outside faucets were not evaluated due to their being winterized with covers, and are excluded from this inspection. (front of house)
     
    Roof Return to table of contents
    Roof inspection method: Traversed
    Roof type: A-frame
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: approximately 4 years old as per owner.
    Roof ventilation: Adequate
    10) One or more roofing shingles are chipped and/or cracked. A qualified roofing contractor should evaluate and replace tiles as necessary.

    Photo 15  
    Isolated shingle damage on rear of roof.

    Photo 21  
    Damaged roof shingles.

    11) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

    Photo 24  
    Tree overhanging near roof.
     

     
    Attic Return to table of contents
    Inspection method: Viewed from hatch
    Roof structure type: Rafters
    Insulation material: Fiberglass roll or batt
    Insulation depth: 6"
    Insulation estimated R value: R 11
    12) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    Photo 10  
    Outlet in attic missing cover plate.
     

    13) Ceiling insulation is missing in some areas. Recommend installing insulation where missing for better energy efficiency.

    The insulation is pulled away from areas near the hatch, but appears to be in attic.

    14) No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
    15) No weatherstrip is installed around the attic access hatch. Weatherstrip should be installed around the hatch to prevent heated interior air from entering attic.
    16) Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection.
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): Undetermined, not labeled
    Service voltage (volts): Undetermined, not labeled
    Location of main service switch: Left side of house
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Copper
    System ground: Ground rod(s) in soil
    Branch circuit wiring type: Copper
    Smoke detectors present: I did not check for smoke detectors. I recommend installing them in every house.
    17) One or more overcurrent protection devices (circuit breakers or fuses) are "double tapped", where 2 or more wires are clamped in a terminal designed for only one wire. This is a safety hazard since the bolt or screw may tighten securely against one wire, but leave others loose. Arcing, sparks and fires may result. A qualified electrician should evaluate and repair as necessary.

    Photo 14  
    Could not confirm if breaker is a
    doulbe tap/ lug type.
     

    18) One or more screws are missing from the main service panel cover and should be replaced. Because energized wiring may exist behind the holes with the missing screws, recommend that a qualified, licensed electrician replace these screws, or that care be taken to ensure that the new screws do not come in contact with wiring inside the panel when they are installed. Stock screws from the panel manufacturer should be used, or their equivalent.
    19) The legend for overcurrent protection devices (breakers or fuses) in the main service panel is missing, unreadable or incomplete. Recommend installing, updating or correcting the legend as necessary so it's accurate. Evaluation by a qualified electrician may be necessary.

    Photo 13  
    Panal screw missing, not properly
    labeled.
     

    20) There is no room for adding additional breakers to the panel. To upgrade or add on will require installing a new electric panal.
     
    Water heater Return to table of contents
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 40
    Manufacturer: Whirlpool
    Model: E2F40RD045V
    21) The water heater was turned off at the time of the inspection. It was unplugged prior to the inspection. The inspector was unable to fully evaluate the water heater.

    Photo 9  
    Water heater information label.

    Photo 23  
    Water heater unplugged.

     
    Heating and cooling Return to table of contents
    Primary heating system energy source: Electric
    Primary heat system type: Forced air
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Flexible ducts
    Manufacturer: Rheem
    Model: RAKA-030JAZ
    Filter location: Behind return air grill
    Last service date: Unknown
    22) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.

    Photo 18  
    A/C coil.

    Photo 17  
    A/C information label.

    Photo 3  
    Air conditioner information label
     

    23) The MAX fuse for the unit is rated at 30 Amps, the fuse in the electric panel appears to be a 40 Amp. I could not confirm this as the panel is not correctly labeled. I recommend a further evaluation.
    24)   The air tempature entering the return was 65 degrees and the average register was 50 degrees.
     
    Plumbing and laundry Return to table of contents
    Location of main water shut-off valve: Rear of house
    Water service: Private
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    25) Recommend having the septic tank inspected. Recommend having the tank pumped if it was last pumped more than 3 years ago.

    The pump for the septic system was running continuously during the inspection. I recommend having it inspected by a professional.

    Photo 16  
    Septic system pump runs constantly.
     

    26) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.

    They are not present, plugged in, or obstructed by owners property.

     
    Crawl space Return to table of contents
    Inspection method: Traversed
    Insulation material underneath floor above: Fiberglass roll or batt
    Pier or support post material: Concrete
    Beam material: Solid wood
    Floor structure above: Solid wood joists
    Vapor barrier present: Not visible
    27) Insulation under the floor in the crawlspace is damaged, deteriorated, or has fallen down. A qualified contractor should make repairs as necessary to restore the insulation to its original rating.

    Photo 2  

    Photo 20  
    No insulation.

    28) Insulation on water pipes is damaged, deteriorated and/or missing in one or more areas. Recommend repairing or installing insulation on water pipes where necessary for better energy efficiency and to prevent water pipes from freezing.

    The copper water suplly lines are missing insulation in some small areas.

    The A/C line is insulated, but is missing or falling off in some areas.

    Photo 11  
    A/C line needs insulation material repaired.

    Photo 12  
    Insulation missing on small areas of copper
    pipe under house.

    29) Some crawl space areas were inaccessible due to low height (less than 18 inches), ductwork or pipes blocking, standing water, and/or stored items. These areas are excluded from this inspection.
     
    Well Return to table of contents
    Location of well equipment: Storage shed in back yard
    30) Recommend having the well water tested for coliform bacteria, nitrates, and anything else of local concern, by a qualified lab. For more information, visit:
    http://www.wellowner.org

    Photo 22  
    Water pump and tank.
     

     
    Kitchen Return to table of contents

    31) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 8  
    No GFCI outlets near kitchen sink.
     

    32) The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit:
    http://www.google.com/search?q=range+anti+tip+device

    33) Lamp holders or light fixtures with fully or partially exposed bulbs are installed in in the laundry room. This is a safety hazard due to the risk of fire. Flammable stored items may come into contact with hot bulbs, and hot fragments from broken bulbs may fall on combustible materials.

    Photo 19  
    Bare bulb in laundry room.
     

    34) The light in range hood is inoperable. Recommend replacing light bulb(s) or having repairs made by a qualified contractor as necessary.

    The exhaust pipe in cabinet should be sealed air tight.

    35)   Many of the drawers and cabinets were full of personal objects and therefore could not be inspected completely.
     
    Bathrooms Return to table of contents

    36) One or more toilets are loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.

    The toilet set is loose on the toilet, it should be tightened

    37) HVL fixture in second bathroom - the light and vent are working correct, but the heat element is not functioning.
    38) The tile floor in the closet has not been trimmed / finished. This is a minor repair that can be completed in a small amount of time.
     
    IMPORTANT NOTICE TO THIRD PARTIES OR OTHER PURCHASERS: RECEIPT OF THIS REPORT BY ANY PURCHASERS OF THIS PROPERTY OTHER THAN THE PARTY(IES) IDENTIFIED ON THE CONTRACT PAGE IS NOT AUTHORIZED BY THE INSPECTOR. THE INSPECTOR PROHIBITS USE AND STRONGLY ADVISES AGAINST ANY RELIANCE ON THIS REPORT. WE RECOMMEND THAT YOU RETAIN A QUALIFIED PROFESSIONAL LICENSED INSPECTOR TO PROVIDE YOU WITH YOUR OWN INSPECTION AND REPORT OF THIS PROPERTY.

    This inspection / report is not meant to be technically exhaustive but an analysis of the general overall condition of this property. This inspection and report is based upon observations of the conditions that existed at the time of the inspection only. This report excludes any and all components, items and conditions, which are concealed or otherwise difficult to inspect. This report does not include an inspection for past or active termite damage or infestation, radon gas, mold, asbestos, lead paint, or any other hazardous materials, substance or dangerous conditions on this property.

    This Report includes a copy of the Louisiana State Board of Home Inspectors Standards of Practice and Code of Ethics. By reading or posesing this report you agree that you have read and understand the Standards of Practice and Code of Ethics and confirm that you have received copies of the documents as part of the report.

    The limitation of liability for errors, omissions or judgment shall be limited to the cost of the service and report. This limitation shall include and apply to all bodily injury and property damages of any nature.
    No warranties or guarantees of any kind are given or implied with this inspection.

    Thank you for choosing Acutec Home Inspectors for your inspection needs. I am here to serve your needs so if you have a question, please feel free to contact me. (985) 290-8993


    _________________________________
    Shawn Gregg - License # 10724
    Louisiana State Board of Home Inspectors