Inspector: Todd Schwalbe

  

Home Inspection Report
Client(s): Sample
Property address: 1234 Main St.
Any Town,Fl.34232
Inspection date: 7/22/ 2005
This report published on 6/7/2006 4:13:19 PM EDT

View summary page


How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
SafetyPoses a risk of injury or death 
Major defectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 
Concern items are sorted by the types listed above.  Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
General information  
Overview: Inspection of unoccupied single family (1) story home for purposes of a real estate transaction
Structures inspected: Home w/pool
Seller's name: John Doe
Report number: 2221
Time started: 7:50 A.M.
Time finished: 9:30 A.M.
Inspection Fee: $425.00
Present during inspection: Buyer, Owner(2) inspectors Steve Weinberger and Todd Schwalbe
Occupied: No
Age of building: 1986
Type of building: Single family
Weather conditions: Partly cloudy
Temperature: Warm
Ground condition: Damp
Main entrance faces: South
Foundation type: Slab on grade
The following items are excluded from this inspection: Irrigation systemUnable to get irrigation system to work
Exterior  
Footing material: Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Concrete block
Wall covering: Wood panels, StuccoT-111 along with stucco
Driveway material: Poured in place concrete
Sidewalk material: Paving stonesSlate tiles
Exterior door material: Solid core steel
Water pressure (psi): 58psi
1) One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of gray water contaminating the potable water supply. Recommend installing backflow prevention devices on all exterior hose bibbs where missing. They are available at most home improvement stores and are easily installed.

For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079
2) Fence in NW corner has considerable wood rot where it is in contact with soil.Recommend repairing and creating proper clearance between wood and the soil.
3) The pool heater had a 3 degree temperture differential when it was run.The heater appears to be at the end of its useful life. Recommend further evaluation by a licensed pool contractor.
4) The fascia on the pool side of the house has some evidence of wood rot caused by either water or wood destroying organisms
5) The two french doors leading to the porch were installed without a permit. Recommend buyer request a permit and county inspection from the seller to determine if it was installed up to proper hurricane standards prior to closing escrow.
6) One or more outside faucets need repair or replacement due to leaking or damage. Recommend that a qualified, licensed plumber repair or replace outside faucet(s) as necessary.
7) Fence gate on the east side of the house shows sign wood rot and needs to be repaired
8) Lap siding above garage door needs to be caulked. Some of the boards have cupped slightly leaving a larger than normal seam.
9) Vegetation (trees, shrubs and/or vines) are in contact with building exterior. Recommend pruning or removing vegetation as necessary so there's at least a one foot gap between all vegetation and the building exterior. This gap should exist to allow exterior building materials to dry quickly after it rains, and to eliminate pathways to the structure for wood destroying insects.
10) Minor cracks in driveway. These are only a cosmetic concern. No action is recommended.
 
Roof  
Roof inspection method: Traversed
Roof type: Cross gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: New
Gutter & downspout material: Aluminum
Roof ventilation: Inadequate
11) Roof was recently reshingled without a permit according to the owner. Recommend having the seller get a permit and county inspection prior to closing escrow as the buyer assumes all liability of the roof after closing of escrow.
12) The shingles were already beginning to cup after less than (6) months indicating that the shingles were not installed correctly on top of the old shingles.It also appears that the corrcet length nails were not used for the shingles.Recommend further evaluation by a licensed roofing contractor or have the seller get a permit and county inspection to verify proper installation
13) This asphalt or fiberglass composition roof has two or more layers of roofing materials. When this roof is replaced, recommend a complete "tear off", where all existing layers of roofing are removed before installing new roofing materials. With each layer of material added to a roof, the new roof material's lifespan is reduced as follows:

  • 16-20 years - First roof
  • 12-16 years - Second layer on existing roof

    Removing existing roofing materials will significantly increase the cost of the next roof.
  • 14) Recommend cleaning gutters.
    15) Trees are overhanging roof and are within 10 feet of roof vertically. Recommend pruning trees so they're at least 10 feet above roof, or don't overhang the roof.
     
    Attached garage  
    16) The garage vehicle door "auto-reverses", but requires too much force. The door should reverse relatively easily when closing and when it strikes something. This is a safety hazard, especially for small children. Recommend having a qualified garage door contractor evaluate and repair as necessary.
    17) Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes and latches automatically to prevent vehicle fumes from entering building.
     
    Electric service  
    Primary service type: Underground
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 150
    Service voltage (volts): 120-240
    Location of main service panel: Garage east wall
    Location of sub panels: Outside by the pool heater
    Location of main disconnect: Breaker at top of main panel
    Service conductor material: Copper
    Main disconnect rating (amps): 150
    Branch circuit wiring type: Non-metallic sheathed
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: YesNewly installed
    18) Timer box for the irrigation system had unterminated wiring in it.Recommend having a licensed electrical contractor make necessary repairs to eliminate the safety issue.
     
    Water heater  
    Estimated age: 1986
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 40
    Brand & model: Rheem 81v-40d
    Water temperature (degrees Fahrenheit): 132 degrees
    19) The estimated useful life for water heaters is 8 to 12 years. This water heater appears to be at this age or older. Recommend budgeting for a replacement in the near future.
     
    Heating and air conditioning  
    Heating system energy source: Electric
    Heat system type: Heat pump
    A/C energy source: Electric
    Air conditioning type: Split system
    Distribution system: Flexible ducts
    Brand & model: Carrier Model #38YKC030300 Serial 3194E17487
    Location of filter(s): Living room wall just inside entryway
    20) The estimated useful life for heat pumps is 15 to 20 years. This heat pump appears to be approaching this age and may need replacing at any time.Air handler was installed in 1986.
    21) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceed this age and may need replacing at any time. The compressor was installed in 1994
    22) This system is equipped with throw-away filter(s). Recommend replacing throw-away filter(s) every 2 months in the future if the thermostat's fan position is set to "Auto", or monthly if it's set to "On".
     
    Attic  
    Inspection method: TraversedEntered from both attic hatches
    Roof structure type: Trusses
    Ceiling structure: Trusses
    Insulation material: Fiberglass roll or batt
    Insulation depth: 4"-5"
    Insulation estimated R value: R-20------R-25
    23) Wire connections exposed due to missing cover plate(s) over one or more junction boxes. Recommend installing cover plates over boxes where missing.
    24) Insulation in attic is substantially less than an R30 rating. Recommend installing additional insulation for better energy efficiency.
    25) No weatherstrip is installed around the attic access hatch. Recommend installing weatherstrip around hatch to prevent heated interior air from entering attic.
    26) Evidence of a rodent infestation is visible in the form of rodent feces, traps and/or poison or burrow holes in insulation. Recommend asking the sellers about this and using traps in the future to prevent rodents from dying in inaccessible areas. The clients may want to consult with a professional exterminator.
     
    Plumbing and laundry  
    Location of main water shut-off valve: SW corner of house
    Location of main water meter: Front of property by sidewalk
    Water service: Public
    Service pipe material: Not visible
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Not visible
    27) The clothes dryer is equipped with a plastic (vinyl) or foil, accordion-type, flexible duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. The flexible plastic or foil type duct can more easily trap lint and is more susceptible to kinks or crushing, which can greatly reduce the airflow. Recommend replacing the duct with a rigid or corrugated semi-rigid metal duct. Most manufacturers specify the use of a rigid or corrugated semi-rigid metal duct, which provides maximum airflow. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
     
    Interior rooms  
    28) No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.
    29) Transition from LR to MB nails are sticking and pose trip hazard
    30) North wall in kitchen eating area under windows moisture meter reading was 97 -99 % indicating current water intrusion.Recommend further evaluation by general contractor to determine extent of the damage.
    31) The kitchen cabinets have extensive water damage and need to be further evaluated by a licensed kitchen contractor to determine the extent of the damage.See attached photo's. Suspect possible mold issues and recommend further testing for WDO
    32) In MB bath the cornerbead at the bottom of the wall by the toilet room door is rusted and bubbling under the new paint
    33) Window(s) stuck shut and can't open. Recommend repairing window(s) so they open easily. SE bedroom and MB bath
    34) Door binds in jamb and is difficult to operate. Recommend repairing door so it opens and closes easily. Garage house door
    35) Loose tiles in guest bathtub area.May or may not indicate water intrusion
      36) The shower in the MB bath has been tiled over without removing the old tiles .We are not able to evaluate if there was water intrusion prior to redoing the shower
     

    Photo 3  
    Wood in direct contact with roof is starting to rot. It should be at least 1 inch above roof.

    Photo 4  
    Wood in direct contact with roof is starting to rot. It should be at least 1 inch above roof.

    Photo 5  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 6  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 7  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 8  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 9  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 10  
    There is much rotting wood that was painted over. This wood needs to be cut out and replaced to prevent future damage.

    Photo 11  
    Many areas around the house need to be caulked.

    Photo 12  
    Many areas around the house need to be caulked.

    Photo 13  
    The roof was just replaced by the home owner ( NOT A LICENSED ROOFING CONTRACTOR ) The owner should provide proof of a final building permit.

    Photo 14  
    The roof was just replaced by the home owner ( NOT A LICENSED ROOFING CONTRACTOR ) The owner should provide proof of a final building permit.

    Photo 15  
    The plumbing vent pipes need the lead boots replaced.

    Photo 16  
    The plumbing vent pipes need the lead boots replaced.

    Photo 17  
    The plumbing vent pipes need the lead boots replaced.

    Photo 18  
    The plumbing vent pipes need the lead boots replaced.

    Photo 19  
    There is much vegetation in contact with the house that needs to be trimmed back. Also the gutters are full causing water to back up.

    Photo 20  
    There is much vegetation in contact with the house that needs to be trimmed back. Also the gutters are full causing water to back up.

    Photo 21  
    The original vents do not appear to be almost blocked by the addition of the second layer of roofing shingles. We recommend replacing these vents to restore proper air flow to the attic space.

    Photo 22  
    The original vents do not appear to be almost blocked by the addition of the second layer of roofing shingles. We recommend replacing these vents to restore proper air flow to the attic space.

    Photo 23  
    The fence is at or beyond its useful service life and will need replacement soon.

    Photo 24  
    The fence is at or beyond its useful service life and will need replacement soon.

    Photo 25  
    The fence is at or beyond its useful service life and will need replacement soon.

    Photo 26  
    Either the ceiling on the covered porch has been poorly repaired or there is a moisture problem.

    Photo 27  
    Either the ceiling on the covered porch has been poorly repaired or there is a moisture problem.

    Photo 28  
    Substandard Wiring / missing electrical box covers.

    Photo 29  
    Substandard Wiring / missing electrical box covers.

    Photo 30  
    Substandard Wiring / missing electrical box covers.

    Photo 31  
    Substandard Wiring / missing electrical box covers.

    Photo 32  
    Substandard Wiring / missing electrical box covers.

    Photo 33  
    Substandard Wiring / missing electrical box covers.

    Photo 34  
    Substandard Wiring / missing electrical box covers.

    Photo 35  
    Substandard Wiring / missing electrical box covers.

    Photo 36  
    Substandard Wiring / missing electrical box covers.

    Photo 37  
    Evidence of moisture/possible mold/ odors.
    No overflow pan & no over flow protection.

    Photo 38  
    Substandard wiring at the air handler.

    Photo 39  

    Photo 40  
    Water heater is leaking & needs replacement.

    Photo 41  
    Water heater is leaking & needs replacement.

    Photo 42  
    Substandard plumbing.

    Photo 43  
    Substandard plumbing.

    Photo 44  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 45  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 46  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 47  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 48  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 49  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 50  
    The kitchen cabinets have been badly damaged by water. These cabinets should be replaced to prevent future damage. Suspect mold behind damaged cabinets.

    Photo 51  
    The sink / counter top tile were installed incorrectly.

    Photo 52  
    The sink / counter top tile were installed incorrectly.

    Photo 53  
    The north /northeast wall in the kitchen eating area has a severe moisture problem that needs to be corrected immediately. Moisture meter readings between 97.1% & 99.9% At the time of inspection.

    Photo 54  
    The north /northeast wall in the kitchen eating area has a severe moisture problem that needs to be corrected immediately. Moisture meter readings between 97.1% & 99.9% At the time of inspection.

    Photo 55  
    Evidence of past or present water leaks.

    Photo 56  
    Evidence of past or present water leaks.

    Photo 57  
    Evidence of past or present water leaks.

    Photo 58  
    Evidence of past or present water leaks.

    Photo 59  
    Evidence of past or present water leaks.

    Photo 60  
    Evidence of past or present water leaks.

    Photo 61  
    Hurricane straps are not fully nailed off. We recommend a nail in every hole of the strap.

    Photo 62  
    Rodent droppings were found through out the attic along with a dead rat.

    Photo 63  
    Rodent droppings were found through out the attic along with a dead rat.

    Photo 64  
    Rodent droppings were found through out the attic along with a dead rat.