Property Inspection Report sample
Client(s): Joe Smith
Property address: 1234 Cocoa Blvd. unit 105
Cocoa Fl. 32927
Inspection date: Thursday, December 03, 2009
This report published on 12/21/2009 10:14:15 AM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Electric service
Water heater
Heating and cooling
Bathrooms
Kitchen
 
General information Return to table of contents
Report number: 1001
Inspector's name: Mike Sewell
Two story multiy family: Condo Frist floor
Age of building: 1986
Time started: 9:30
Time finished: 12:30
Inspection Fee: 250.00
Payment method: comp
Present during inspection: Property owner(s)
Occupied: Yes
Weather conditions: Partly cloudy
Temperature: Warm
Ground condition: Damp
Front of structure faces: North
Main entrance faces: North
Foundation type: Slab on gradeconcrete
The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Shed, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court, Sea wall, Outbuildings
1) Electrical outlet near kitchen sink is not GFCI protected
 
Exterior Return to table of contents
Footing material: Not visible
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Vinyl
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
2) Minor cracks were found in the sidewalk. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 19  
 
 
Roof Return to table of contents
Roof inspection method: Viewed from ground with binoculars
Roof type: hipp
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 5yrs
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
3) The roof is mantianed by the condo assocation it is in overall good condition.
4) All of the gutters and down spouts are in good condition and flow away from the building
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service voltage (volts): 120/240
Location of main service switch: west side of building
Location of main disconnect: No single main disconnect, use all breakers in main service panel
Service entrance conductor material: Copper
System ground: Ground rod(s) in soil
Smoke detectors present: Yes
 
Water heater Return to table of contents
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
Water temperature (degrees Fahrenheit): 120
5) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
6) Corrosion was found in one or more areas on the water heater. The water heater may be failing. A qualified plumbing contractor should evaluate and replace or repair water heater if necessary.

Photo 12  

Photo 13  

7) Corrosion was found on fittings and/or water supply lines for the water heater. Leaks may exist. A qualified plumbing contractor should evaluate and repair as necessary.

Photo 10  
 
 
Heating and cooling Return to table of contents
Estimated age: 6yrs
Primary heating system energy source: Electric
Primary heat system type: Heat pump
Primary A/C energy source: Electric
Primary Air conditioning type: Heat pump
Distribution system: Flexible ducts
Manufacturer: Carrier
Filter location: Behind return air grill
Last service date: 7/2009
8)

Photo 30  
Corrosion in this area possible leak
 
 
Bathrooms Return to table of contents

9) One or more sink drains have an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified plumber should evaluate and repair as necessary.

Photo 5  
Leaks @ pop up stopper seals causing damage to vanity shelf in both bathrooms

Photo 6  
Leaks @ pop up stopper seals causing damage to vanity shelf in both bathrooms

Photo 9  
Leaks @ pop up stopper seals causing damage to vanity shelf in both bathrooms
 

10) One or more sink stopper mechanisms are missing, or need adjustment or repair. Stopper mechanisms should be installed where missing and/or repairs should be made so sink stoppers open and close easily.

Photo 2  
Pop up stopers are missing in the master bath

Photo 3  
Pop up stopers are missing in the master bath

11) Water damage was found in the shelving or cabinet components below one or more sinks. A qualified contractor should evaluate and make repairs as necessary.

Photo 8  
Leaks @ pop up stopper seals causing damage to vanity shelf in both bathrooms
 
 
Kitchen Return to table of contents

12) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

Photo 23  
 

13)

Photo 16  
food grinder in good woking condition time of inspection

Photo 17  
microwave stove top and oven in good woking condition time of inspection

Photo 24  
dishwasher in working order at time of inspection
 
 

Photo 1  
outlets in master bath are protected by the GFCI in guest bath

Photo 4  
outlets in master bath are protected by the GFCI in guest bath

Photo 7  
GFCI in guest bath in good working order

Photo 11  
TPR valve top of water heater exits to outside

Photo 14  
Electic pannal in laundary closet

Photo 15  
washer drier in good woking condition time of inspection

Photo 18  
Fire exstingusher @ entrance of building

Photo 20  
water sevice north side of building

Photo 21  

Photo 22  
air handler in hallway

Photo 25  
water service shut off valve

Photo 26  
most windows do not operate properly, screens are damaged

Photo 27  
main entrance

Photo 28  
Electric main shut off on west end of building

Photo 29  

Photo 31  
AC main shut off braker

Photo 32  
drier vent

Photo 33  
hot water heater discharge pipe out side

Photo 34  
window screens damaged
 

 