The maximum developed length of a clothes dryer exhaust duct shall not exceed 35 feet from the dryer location to the wall or roof termination. The maximum length of the duct shall be reduced 2.5 feet for each 45-degree (0.8 rad) bend, and 5 feet for each 90-degree (1.6 rad) bend.
People also ask
Nov 6, 2021 · The guideline for vent length is a maximum distance of 35 feet subtract 2.5 feet for every 45° bend and subtract 5 feet for every 90° bend.
Available in 10 and 20 foot lengths. Dryer Venting Comparison Chart. The chart below shows the manufacturer recommendations** for maximum vent length under ...
The maximum length of the exhaust duct shall be 35 feet (10 668 mm) from the connection to the transition duct from the dryer to the outlet terminal. Where ...
maximum length dryer duct from thelintking.com
Industry standards recommend that the maximum “concealed” rigid metal ducted clothes dryer vent length be no more than 25 feet. The effective length of a dryer ...
Jan 22, 2022 · The length cannot be more than 25-feet; it should also be as straight as possible. If there is a 90-degree angle in the vent, then it shouldn't ...
maximum length dryer duct from dryerbox.com
Length of concealed rigid metal ducting shall not exceed 35 feet (25' for IRC). Deduct 5 feet from the allowable length for every 90 degree elbow and two and a ...
maximum length dryer duct from www.finehomebuilding.com
Sep 10, 2008 · Dryer duct runs longer than 25 ft. usually require a booster fan, which can extend the length limit to 60 ft. Inline fans such as the one ...