Summary Page

Property Inspection Report
Client(s): Sample Client
Property address: 5555 Anywhere Drive
Central, MD 2100005
Inspection date: 12/31/2010

This summary page published on 2/9/2011 2:58:09 PM EST

Return to report

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
This report is prepared under the Maryland Standard of Practices.
©Copyright 2010 4U Home, Inc.
All rights reserved. No part of this material may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage and retrieval system without permission in writing from the owner of this copyright. Inquiries should be addressed to 4U Home, Inc., 8775 Cloudleap Court, Suite P57, Columbia, MD 21045.
Not responsible for typographical errors

Concerns are shown and sorted according to these types:
Safety ConcernDenotes a condition that is UNSAFE and in need of PROMPT ATTENTION 
Significant IssuesA system or component that is considered significantly deficient, inoperable or unsafe by current building standards 
Repair/ReplaceIndicates the component will need repair or replacement now or in the near future 
Budget for ReplacementRepair likely within Five years and may involve a significant expense 
Repair/MaintainRecommend repair and/or maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

General information
1) - This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

Exterior
2) - Step is wobbly do to pulled nails. A qualified contractor should evaluate and repair as necessary, such as screwing and gluing steps to prevent wobbling.

3) - Window well higher than three feet exist on this property and guardrails or barriers are missing or inadequate. This is a safety hazard due to the risk of falling. At a minimum, the client(s) should be aware of this hazard, especially when children are present. Ideally a qualified contractor should install adequate guardrails or reinstall existing barriers to eliminate fall hazards.

4) - One or more areas of the grounds around the structure have significantly soggy soil, standing water or indications of accumulated water at times (sediment, dead grass, etc.). Recommend consulting with a qualified contractor who specializes in drainage, to determine if or what repairs are needed to provide adequate drainage. Possible repairs may involve grading soil, or installing, repairing and/or replacing underground drains.

5) - One or more gutters are poorly sloped so that significant amounts of water accumulate in them rather than draining through the downspouts. This can cause gutters to overflow, especially when organic debris such as leaves or needles have accumulated in them. A qualified contractor should evaluate and make repairs as necessary, such as correcting the slope in gutters or installing additional downspouts and extensions if necessary.

6) - Siding is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs and/or replace siding as necessary to prevent water and vermin intrusion.

7) - Front deck area joist member has warped and twisted causing it to detach from sister joist. Appears that water from downspout has destabilized support post causing the twist. Joist needs replaced and recommend bolting together adhering to good building practices. Support post needs to be stabilized and water diverted from this area. Recommend a qualified contractor evaluate for repair and/or replacement.

8) - Gap between gutter and siding appears to be allowing water by pass gutter. This is evident by rot in trim board and moisture in corner area of wall. This appears to attributing to the moisture intrusion appearing on the basement joist. It is recommended that a qualified contractor evaluate for repair.

9) - Due to erosion the window well casing has pulled away from foundation wall. A qualified contractor should evaluate for repair and/or replacement. This evaluation should include the downspout extensions, which appear to be the root cause on the deterioration.

10) - One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:

  • Hydraulic cement. Requires chiseling a channel in the crack to apply.
  • Resilient caulks (easy to apply).
  • Epoxy sealants (both a waterproof and structural repair).
    11) - Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

    12) - One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.

    13) - One or more wooden deck support posts are in contact with soil. This is a conducive condition for wood destroying insects and organisms. However no damage from wood destroying insects or organisms was found. Standard building practices require that there be at least 6" of space between any wood and the soil below, even if the wood is treated. If possible, soil should be removed or graded so a 6" clearance is maintained. Otherwise recommend installing borate based Impel rods to prevent rot. For more information, visit:
    http://www.google.com/search?q=impel+rods

    14) - Rot was found in one or more areas on trim boards. A qualified contractor should evaluate and make repairs as necessary, replacing all rotten wood.

    Garage
    22) - The garage-house door isn't equipped with an automatic closing device such as sprung hinges. This door should close and latch automatically to prevent vehicle fumes from entering living spaces and/or to slow the spread of fire from the garage to living spaces. A qualified contractor should install automatic closing device(s) as necessary, and as per standard building practices, so this door closes and latches automatically.

    23) - The garage vehicle door is damaged or deteriorated. A qualified contractor should evaluate and repair or replace the door as necessary.

    Attic
    24) - Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    25) - One or more exhaust fan ducts are broken and/or have fallen down, or somehow terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should evaluate and make permanent repairs as necessary and as per standard building practices, so all exhaust air is vented outside.

    Electric service
    28) - The main service panel cover couldn't be removed due to lack of access from shelving, cabinets, walls and/or ceilings. This panel wasn't fully evaluated. Repairs should be made so the panel cover can be easily removed.

    Water heater
    29) - Hot water heater appears to have failed. Water filled drip pan, corrosion and water where on tank below first heat element panel. When opened corrosion and water was dripping from element and had filled the plastic liner of tank. Do to shock hazard power was disengaged and upon texted approval from selling agent water supply was disengaged.

    Heating and cooling
    30) - Moisture stains were observed on furnace. This appears to be a result of the condensation line not draining properly. Due to temperature unit could not be engaged to test. It is recommended that the client monitor this area when weather is warm enough to engage A/C unit check unit for proper drainage. If moisture is observed have a qualified HAVC contractor evaluate for repair.

    31) - One or more air supply ducts are broken or disconnected. Increased moisture levels in unconditioned spaces and higher energy costs may result. A qualified contractor should evaluate and make permanent repairs as necessary.

    32) - The outside condensing unit is not level. Damage may occur if it is more than ten degrees off from level. A qualified contractor should evaluate and make repairs as necessary, such as replacing the pad that the condensing unit is installed on.

    33) - Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.

    Plumbing and laundry
    38) - No ground fault circuit interrupter (GFCI) protection device is visible for the sump pump electric supply. A qualified electrician should determine if a GFCI protection device (receptacle or circuit breaker) exists for the sump pump and install one if missing to reduce the danger of electric shock.

    39) - The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information, visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

    40) - Washing machine leaks at supply line. A licensed plumber should evaluate and repair as necessary.

    41) - The laundry sink is not anchored to the wall or floor. A qualified contractor should securely anchor the sink to the wall and/or floor to prevent damage to and leaks in the water supply and/or drain pipes due to the sink being moved.

    Fireplaces, woodstoves and chimneys
    45) - Fireplace hearths are damaged and/or deteriorated with broken tiles. A qualified contractor should evaluate and make repairs as necessary.

    Basement
    47) - Evidence of prior water intrusion was found in the window well area of the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary.

    48) - One or more areas of the basement joist structure appeared to be wet or had elevated levels of moisture at the time of the inspection. There appears to be an active leak in the roof or structure exterior. A qualified contractor should evaluate and repair as necessary.

    Kitchen
    49) - The dishwasher appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, the dishwasher should be replaced, or a qualified appliance technician should evaluate and repair.

    Bathrooms
    51) - The "flapper valve" in the hallway toilet did not reseat after flushing. Significant amounts of water can be lost through such leaks. A qualified plumber should evaluate and repair or replace components as necessary.

    52) - The shower diverter valve for one or more bathtub faucets is defective. A significant amount of water comes out of the bathtub spout when the shower is turned on. Water will be wasted as a result. A qualified plumber should evaluate and replace components or make repairs as necessary.

    53) - In master bath, whirlpool tub stopper would not engage, could not fully evaluate the Tub.

    Interior rooms
    56) - Guardrails are missing from back entrance that is a elevated surface with high drop-off. This is a safety hazard due to the risk of falling. Standard building practices require guardrails to be installed at drop-offs higher than 30 inches, but in some cases it is advised to install them at shorter drop-offs and to prevent egress from this area. A qualified contractor should evaluate and install guardrails or install steps in this area as necessary and as per standard building practices.

    57) - One or more smoke alarms are damaged, deteriorated and/or missing from their mounting brackets. Damaged and/or missing smoke alarms should be replaced as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    58) - Deterioration, leaning and/or bowing were found in walls of stairwell. Due to the amount of bowing it is recommeded that the client have a qualified structural engineer evaluate to determine what repairs are necessary. Repairs should be made by a qualified contractor.