Property Inspection Report
Client(s): John Smith
Property address: 5329 Meadowood drive
Inspection date: 1/31/2011
This report published on Thursday, June 16, 2011 10:05:49 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Interior rooms
Bathrooms
Kitchen
Plumbing and laundry
Heating and cooling
Water heater
Electric service
Basement
Attic
 
General information Return to table of contents
Report number: 003
Inspector's name: Bill Bose
Structures inspected: House and Garage
Type of building: Single family
Age of building: 58 yrs.
Property owner's name: John Smith
Time started: 11:15
Time finished: 3:50
Inspection Fee: 250.00
Payment method: Cash
Present during inspection: Property owner(s)
Occupied: Yes
Weather conditions: Snow
Temperature: Cold
Ground condition: Frozen
Front of structure faces: North
Main entrance faces: North
Foundation type: Unfinished basement
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core wood
1) One or more flights of stairs with more than two risers have no handrail installed. This is a safety hazard. A qualified contractor should install graspable handrails that your hand can completely encircle at stairs where missing, and as per standard building practices.

Photo 4  
 

2) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

Photo 2  
 
 
Roof Return to table of contents
Roof inspection method: Traversed
Roof type: Hipped
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 5 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
3) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.

Photo 3  
 
 
Garage Return to table of contents

4) One or more wall and/or ceiling surfaces between the attached garage and interior living spaces have gaps, holes, or missing or inadequate surface materials. These surfaces are intended to prevent vehicle fumes from entering living spaces, and to slow the spread of fire from the garage to living spaces. A qualified contractor should evaluate and make repairs as necessary so the attached garage wall and ceiling surfaces that adjoin living spaces are tightly sealed and fire rated as per standard building practices. Typically these surfaces require a one-hour fire rating.

Photo 6  
 

5) Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles.

Photo 7  
 

6) Weatherstrip at the sides and/or bottom of the vehicle door is missing. It should be installed where missing to prevent water and vermin intrusion.

Photo 8  
 
 
Interior rooms Return to table of contents

7) The light fixture at one or more sets of stairs with living spaces at both ends is controlled by a single switch at one end. This is a safety hazard due to inadequate lighting. The light should be controlled by three-way switches at the top and bottom of the stairs so it can be easily operated on both floors. A qualified electrician should evaluate and make repairs as necessary.

Photo 17  
 

8) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.

Photo 5  
 

9) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

Photo 9  
 
 
Bathrooms Return to table of contents

10) One or more exhaust fans is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary.

Photo 12  
 

11) Electrical switch for bathroom exhaust fan not found. Recommend qualified electrician to evaluate and repair.

Photo 12  
 

12) Caulk is missing or deteriorated along the base of one or more bathtubs, where flooring meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the floor structure.

Photo 11  
 

13) Caulk is missing around shower head pipe and trim ring.Recommend caulking area around trim ring to eliminate further water intrusion and possible water damage.

Photo 10  
 
 
Kitchen Return to table of contents

14) Vinyl flooring in one or more "wet" areas is damaged and/or deteriorated. The wooden subfloor below may be damaged by water intrusion. A qualified contractor should evaluate and replace or repair the damaged flooring.

Photo 16  
 

15) Kitchen cabinet pull drawer operation is blocked by stove. Placement of the stove appears to be too close to cabinet. Recommend general contractor to evaluate stove / cabinet arrangement and repair.

Photo 15  
 
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 50
Location of main water shut-off valve: Basement
Location of main water meter: Street
Location of main fuel shut-off: Basement
Visible fuel storage systems: None
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Galvanized steel
Drain pipe material: Plastic
Waste pipe material: Galvanized steel
16) The inspector was not able to find the water meter. Recommend that the client(s) attempt to find the water meter by consulting with the property owner(s), searching for it themselves, or consulting with the local water municipality. It is especially important to find the meter if no main shut-off valve is found because the meter may be the only way to turn off the water supply in the event of an emergency, such as when a supply pipe bursts.
 
Heating and cooling Return to table of contents
Estimated age: 11 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts
Manufacturer: Bryant
Filter location: In return air duct below furnace
Last service date: 2008
17) The air handler's filter(s) are loose or not securely installed. As a result, unfiltered air will flow through the system. The heating/cooling equipment service life and the indoor air quality may be reduced. A qualified contractor should make repairs as necessary, such as repairing or installing guides or retaining devices so filter(s) are securely installed with minimal gaps at edges.

Photo 20  
 

18) The last service date of this system appears to be more than two years ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than two years ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future, or as per the contractor's recommendations.
19) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
 
Water heater Return to table of contents
Estimated age: 12 years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: Rheem
Model: 21V40-7
Water temperature (degrees Fahrenheit): 135
20) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 18  
 
 
Electric service Return to table of contents
Primary service type: Overhead
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Basement
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Copper
System ground: Ground rod(s) in soil
Main disconnect rating (amps): 200
Branch circuit wiring type: Copper
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes
21) Loose electrical wiring in laundry room.Exsisting electrical wiring has become loose from mounting staples over service panel and hanging clothes rack. Recommend qualified electrician to evaluate and repair.

Photo 21  

Photo 23  

22) Extension cord used as permanate wiring.Extension cords are for temporary use only and may become defective over time. Recommend removing extension cord and plug appliance into correct gounded electrical outlet

Photo 14  
 
 
Basement Return to table of contents
Insulation material underneath floor above: None visible
Pier or support post material: Steel
Beam material: Solid wood
Floor structure above: Solid wood joists
23) One or more joists are damaged due to non-standard or substandard notching and/or hole boring. Standard building practices specify the following limitations for notching and boring joists:

  • Notches should not be cut in the middle third of any joist
  • Notches should not be deeper than 1/6 of the joist depth
  • Notches should not be deeper than 1/4 of the joist depth at joist ends
  • Bored holes should not be closer than 2 inches to the edges of the joist
  • Bored holes should not be wider than 1/3 of the joist depth

    A qualified contractor should evaluate and repair as necessary.

    Photo 19  
     

    24) Wire splices are exposed due to not being contained in a covered junction box. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes with cover plates where needed to contain wiring splices.

    Photo 22  
     
     
    Attic Return to table of contents
    Inspection method: Traversed
    Roof structure type: Rafters
    Ceiling structure: Ceiling beams
    Insulation material: Mineral wool loose fill
    Insulation depth: 4 inches
    Insulation estimated R value: R-13
    25) One or more sections of wiring that weren't terminated were found. This is a potential safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary. For example, cutting the wire to length and terminating the wire with wire nuts in a securely anchored, covered, properly sized junction box.

    Photo 27  
     

    26) Some wiring is loose, unsupported, or inadequately supported. Standard building practices require non-metallic sheathed wiring to be trimmed to length, attached to runners or to solid backing with fasteners at intervals of 4-1/2 ft. or less. Fasteners should be installed within 12 inches of all enclosures. A qualified, licensed electrician should evaluate and repair as necessary. For example, trim wire to length and/or install staples as needed.

    Photo 26  
     

    27) The attic exhaust fan was inoperable during the inspection. Recommend consulting with the property owner(s) as to how it operates and/or having a qualified contractor evaluate and repair if necessary.

    Photo 25  
     

    28) Ceiling insulation is missing in some areas. Recommend installing insulation where missing for better energy efficiency.

    Photo 24  
     

    29) One or more exhaust fans have no duct and terminate in the attic. This is a conducive condition for wood destroying insects and organisms due to increased moisture levels in the attic from the exhaust air. A qualified contractor should install ducts and vent caps as necessary and as per standard building practices so exhaust air is vented outside. Better building practices call for R8 rated insulation on these ducts.

    Photo 13  

    Photo 28  

     
    Thank you for using 360 Home Inspections! If I can be of further assistance please contact me at bose360@att.net or (317) 697-6751.